Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 29652-2013 English PDF

US$299.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 29652-2013: Direct reduced iron -- Determination of carbon and sulfur -- High frequency combustion with infrared absorption method
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 29652-2013299 Add to Cart 3 days Direct reduced iron -- Determination of carbon and sulfur -- High frequency combustion with infrared absorption method Valid

Similar standards

GB/T 37829   GB/T 36144   GB/T 27692   GB/T 24204   GB/T 24237   GB/T 10322.3   

Basic data

Standard ID: GB/T 29652-2013 (GB/T29652-2013)
Description (Translated English): Direct reduced iron -- Determination of carbon and sulfur -- High frequency combustion with infrared absorption method
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: D31
Classification of International Standard: 73.060.10
Word Count Estimation: 13,151
Quoted Standard: GB/T 6682; GB/T 6730.1; GB/T 12806; GB/T 12808; GB/T 24239
Adopted Standard: ISO 9686-2006; MOD
Regulation (derived from): National Standards Bulletin 2013 No. 17
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies: high-frequency combustion infrared absorption spectrometry DRI carbon and sulfur content. This standard applies to: DRI carbon and sulfur content determined. Measurement range (mass fraction): 0. 05% to 2. 5% carbon, 0. 001% to 0.

GB/T 29652-2013: Direct reduced iron -- Determination of carbon and sulfur -- High frequency combustion with infrared absorption method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Direct reduced iron. Determination of carbon and sulfur. High frequency combustion with infrared absorption method ICS 73.060.10 D31 National Standards of People's Republic of China Determination of direct reduced iron carbon and sulfur content Frequency combustion infrared absorption method (ISO 9686.2006Directreducediron-Determinationofcarbonand/orsulfur -High-Frequencycombustionmethodwithinfraredmeasurement, MOD) Issued on. 2013-09-06 2014-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard uses redrafted law revision using ISO 9686.2006 "DRI carbon dating and/or sulfur content of the high-frequency combustion Infrared absorption method. " This standard and ISO 9686.2006 and the technical differences for the following reasons. --- On normative references, this standard has been adjusted technical differences, in order to adapt our technical conditions, the adjusted situation Focus is reflected in the status of Chapter 2, "Normative references", the specific adjustments are as follows. • Use revise international standards of GB/T 6682 instead of ISO 3696; • Use identical with international standards GB/T 6730.1 instead of ISO 7764; • Use non-equivalent to international standards of GB/T 12806 replaces ISO 1042; • Use equivalent to international standards of GB/T 12808 replaces ISO 648; • Use identical with international standards GB/T 24239 replaces ISO 10835. --- The standard Chapter 5 adds furnaces, crucible tongs and balance, which is the use of the instrument in the analysis step. --- The standard Chapter 7 increase in the content "analysis ready", as well as direct reduced iron standard sample to calibrate the calibration curve Party Method so that the method is more feasible. The standard proposed by China Iron and Steel Association. This standard by the national iron ore and direct reduced iron Standardization Technical Committee (SAC/TC317) centralized. This standard was drafted. Shougang Caofeidian Exit Inspection and Quarantine, Metallurgical Industry Information Standards Institute. The main drafters of this standard. Yang Zhiqiang, heart Song Peng, Zhang Dongsheng, Liu Weiping, Zhao Jianxing, Wang Chaogang, Chenzi Bin. Determination of direct reduced iron carbon and sulfur content Frequency combustion infrared absorption method Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.

1 Scope

This standard specifies the determination DRI carbon and sulfur content of the high-frequency combustion infrared absorption method. This standard applies to direct reduced iron determination of carbon and sulfur content. Measurement range (mass fraction). 0.05% to 2.5% carbon, sulfur 0.001% to 0.05%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD) GB/T 6730.1 Method for analysis of chemical analysis of iron pre-drying of the sample preparation (GB/T 6730.1-1986, idt ISO 7764. 1985) GB/T 12806 Laboratory glassware single marking flask (GB/T 12806-2011, ISO 1042.1998, NEQ) GB/T 12808 standard laboratory glassware single line pipette (GB/T 12808-1991, eqv ISO 648. 1977) GB/T 24239 Direct reduced iron and hot briquette iron sampling and sample preparation method (GB/T 24239-2009, ISO 10835.2007, IDT) Principle 3 Samples in an induction furnace in an oxygen stream of heated combustion, carbon is converted to carbon dioxide, the sulfur is converted to sulfur dioxide, carbon dioxide and two Sulfur dioxide absorption of a specific wavelength of infrared energy absorbed is proportional to its concentration can accept energy detector according to the change can be measured carbon and sulfur Content.

4 Reagents and materials

Analysis Unless otherwise stated, use only reagents of recognized analytical grade and distilled water or equivalent purity of its water, in line with GB/T 6682 Provisions. 4.1 oxygen than 99.5% purity. 4.2 Dynamic air, nitrogen or compressed air, which contaminants (oil and water) content of less than 0.5%. 4.3 asbestos caustic soda, granular. 4.4 Magnesium perchlorate anhydrous particle size of 0.7mm ~ 1.2mm. 4.5 tungsten particles, the carbon content is less than 0.002%, a sulfur content of less than 0.0005%. 4.6 tin particles, the carbon content is less than 0.002%, a sulfur content of less than 0.0005%. 4.7 iron, the carbon content is less than 0.002%, a sulfur content of less than 0.0005%.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 29652-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 29652-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 29652-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 29652-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.