GB/T 29558-2013 English PDFUS$314.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29558-2013: Surface chemical analysis -- Auger electron spectroscopy -- Repeatability and constancy of intensity scale Status: Valid
Basic dataStandard ID: GB/T 29558-2013 (GB/T29558-2013)Description (Translated English): Surface chemical analysis -- Auger electron spectroscopy -- Repeatability and constancy of intensity scale Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G04 Classification of International Standard: 71.040.40 Word Count Estimation: 16,141 Adopted Standard: ISO 24236-2005, IDT Regulation (derived from): National Standards Bulletin No. 10 of 2013 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies: an assessment of its intensity scale repeatability and constancy methods. It applies only to clean with a sputter ion gun instrument. This standard does not purport to be a strength/energy response function calibration, This calib GB/T 29558-2013: Surface chemical analysis -- Auger electron spectroscopy -- Repeatability and constancy of intensity scale---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Surface chemical analysis.Auger electron spectroscopy.Repeatability and constancy of intensity scale ICS 71.040.40 G04 National Standards of People's Republic of China Surface chemical analysis - Auger electron spectroscopy Repeatability and consistency of intensity scale (ISO 24236.2005, IDT) Issued on. 2013-07-19 2014-03-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard uses the translation method identical with ISO 24236.2005 "Surface chemical analysis - Auger electron spectroscopy and repeatability of intensity scale consistency". The standard micro-beam analysis by the National Standardization Technical Committee (SAC/TC38) and focal points. This standard is drafted by. China University of Science and Technology Department of Physics. Drafters of this standard. DING ZE-JUN, Zhangzeng Ming, who glory, Mao Shifeng, Li Yonggang, Mei Hongping.IntroductionThe material is widely used in surface analysis by Auger electron spectroscopy (AES). Elements in the sample (except hydrogen and helium) can be measured by comparing Outgoing Auger electron kinetic energy corresponding to the value of the different elements of the manual to identify the table values. For information about the content of these elements can be measured from the Auger electron intensity was obtained. The formula to calculate the content available and relative sensitivity factors provided by the spectrometer manufacturer to carry out. weight To the sensitivity factors to be applied to the spectrometer, and this is precisely when the general spectrometer installed or by the appropriate body strength equipment/energy The response of function after calibration. This standard focuses on two aspects of the Auger electron spectroscopy instrument intensity measurement uncertainty important contribution. 2) intensity over time drift; 1) strength measurement repeatability. Repeatability analysis of the differences and similarities between similar samples is important. Instrument limit measurement repeatability factors include. electron-beam source The stability of the detector sensitivity settings, the instrument is placed on the sample, the data acquisition parameters and data processing steps. The strength of the underlying instrument drift The accuracy of the overall shift will limit any quantitative analysis, it is the source. EDS structural components, electronics accessories and detector aging equivalent should. It has been found, Auger electron spectroscopy During use, the strength of the instrument/energy response function can change over the life of the instrument. This standard describes the strength of the underlying instrument to determine the repeatability and consistency of a simple way in order to make the following correction, such as improved Operating procedures, reset or recalibrate the instrument parameters intensity/energy response function. Therefore, this method should be regularly implemented, and the manufacturer The most useful cycle or other appropriate institutions for verification of instrument work properly. The method uses a copper (Cu) sample, and an electron gun beam suitable for Can at least 2keV Auger electron spectroscopy. Since the required test can be very time consuming and requires expert knowledge and auxiliary equipment, so this method is not possible to cover all the instruments missing trap. However, this conventional method is to solve the basic problem of Auger electron spectroscopy repeatability and drift intensity scale and design. This Method with the use of ISO 17973 [1] or ISO 17974 [2] spectrometer energy calibration performed simultaneously. Surface chemical analysis - Auger electron spectroscopy Repeatability and consistency of intensity scale1 ScopeEnergy electron gun for use in routine analysis of at least 2keV Auger electron spectroscopy, this standard provides an assessment of its strong Repeatability and constancy of the subject methods. It applies only to a sputter ion gun cleaning equipment. This standard is not intended to become a Species intensity/energy response calibration functions such calibration by equipment manufacturers or other bodies to develop. The method provides data to assess and determine Recognized instrument intensity/energy response function to maintain a constant accuracy, this can affect the constancy of some instrument settings given guidance.2 SymbolBy HL differential mode CuL3VV average peak peak - peak height HLj a set of measurements in the measurement of the value of the j HL contribution Under HM differential mode CuM2,3VV average peak peak - peak height H Mj a set of measurements in the j-th value measurement of HM contribution i Pi, one of the five parameters identifier Mark j parameters Pij one single measurement CuL3VV peak located directly under the NL average maximum intensity mode NLj a set of measurements in the measurement of the value of j-th contribution NL CuM2,3VV position of the peak at an average maximum intensity NM Direct Mode NMj a set of measurements in the measurement of the value of j-th contribution NM Pi represents the parameter HL, HM, NL, NM and HL/HM any one of the average Pij having the j-th average value of Pi measured parameter Uncertainty of average value of Pi U95 P () i confidence level of 95% W peak FWHM β analog system scan rate δ confidence level of 95% (set by analysts) when HL/HM tolerance limits σP () parameter Pi repeatability standard deviation The time constant τ analog detection system3 Method SummaryThis summary is intended to facilitate the detailed steps presented in Chapter 4 understanding. This step is evaluated by Auger electron spectroscopy, and need to get registration Preparation of reference foil, and electronics to measure CuM2,3VV Auger peak intensity CuL3VV where appropriate instrument settings. We chose these Peak is low because of their proximity kinetic analysis of the actual end use. They have been recognized, and corresponding reference data. Choose low CuM2,3VV peak energy, which is due to its energy range can be used to monitor stray fields undesirable change in strength. 4.1 to 4.5 describes the initial steps of sample preparation and instrument settings, as shown in the flowchart in Figure 1, the figure in the corresponding sub-headings paraphrase. If you do not do strength repeatable measurements should be 4.6 to 4.7 feed. In 4.7, the order of repeated measurements and 7 times CuM2,3VV CuL3VV peak intensity. These data give the peak intensity repeatability standard deviation, both from the electron beam intensity, energy spectrometer detectors and electronics attached ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29558-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 29558-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 29558-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29558-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |