GB/T 29515-2013: Cold rolled steel sheet for enameling -- Fish-scaling sensitivity test -- Hydrogen permeation method
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 29515-2013189 Add to Cart 3 days Cold rolled steel sheet for enameling -- Fish-scaling sensitivity test -- Hydrogen permeation method Valid

Similar standards

GB/T 34487   GB/T 31930   GB/T 29459.2   GB/T 45597   GB/T 33820   GB/T 45169   

Basic data

Standard ID: GB/T 29515-2013 (GB/T29515-2013)
Description (Translated English): Cold rolled steel sheet for enameling -- Fish-scaling sensitivity test -- Hydrogen permeation method
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: H22
Classification of International Standard: 77.040.10
Word Count Estimation: 8,817
Regulation (derived from): National Standards Bulletin 2013 No. 6
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the method for the determination dual electrolytic cell with a cold-rolled steel enamel fishscale sensitivity test principle hydrogen permeation method, the test apparatus and the electrolyte, sample, test procedures, test reports,

GB/T 29515-2013: Cold rolled steel sheet for enameling -- Fish-scaling sensitivity test -- Hydrogen permeation method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cold rolled steel sheet for enamelling. Fish-scaling sensitivity test. Hydrogen permeation method ICS 77.040.10 H22 National Standards of People's Republic of China Enameling cold-rolled steel scales explosion sensitivity test Hydrogen permeation method Issued on. 2013-05-09 2014-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Iron and Steel Association. This standard by the National Steel Standardization Technical Committee (SAC/TC183) centralized. This standard is drafted by. Wuhan Iron and Steel (Group) Company. The main drafters. Zhang Wan Ling, Wei expedition, Chen Xiaohong, Liu Jianrong, Yang can.

Introduction

Enameling cold-rolled steel scales blast susceptibility testing method generally comprises hydrogen permeation and enamelling law, this standard uses a hydrogen permeation measurement scales steel Explosion sensitivity. Enameling cold-rolled steel scales explosion sensitivity test Hydrogen permeation method

1 Scope

This standard specifies the dual cell assay enameling cold-rolled steel scales explosive hydrogen permeation test principle sensitive method, test equipment and electronic Hydrolyzate, samples, test procedures, and test results of the calculation reports. This standard applies to a thickness of 0.3mm ~ 3.0mm enamel sensitivity was measured using cold-rolled steel scales explosion. Principle 2 When charging hydrogen electrolysis, hydrogen ions (H) to reach the surface of the specimen as a cathode, to become a hydrogen atom into the sample, the sample surface to the other diffusion time, Re is a hydrogen atom electrolytically oxidized into hydrogen ions (H), by detecting the anode current of hydrogen oxidation process, to assess the hydrogen atoms in the sample Diffusion process. When the time required for the diffusion of hydrogen called stable hydrogen permeation time tb, tb longer, anti-enamel scale burst performance, the better. by tb defined sample anti-enamel scale explosion sensitivity TH.

3 Chemicals

Chemicals used in the test were of analytical grade, test water is deionized water.

4 test device and the electrolyte

4.1 test device Test device shown in Figure 1, the specimen is clamped between two cells A and B are not mutually connected. A termination galvanostat, B termination constant potential , Automatic recording current variations are oxidized after permeation through the data collection system.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 29515-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 29515-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 29515-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 29515-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.