GB/T 29023.2-2016 English PDFUS$594.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29023.2-2016: Measurement and characterization of particles by acoustic method -- Part 2: Guidelines for linear theory Status: Valid
Basic dataStandard ID: GB/T 29023.2-2016 (GB/T29023.2-2016)Description (Translated English): Measurement and characterization of particles by acoustic method -- Part 2: Guidelines for linear theory Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A28 Classification of International Standard: 19.120 Word Count Estimation: 30,366 Date of Issue: 2016-02-24 Date of Implementation: 2016-06-01 Quoted Standard: GB/T 29023.1-2012; ISO 14488-2007 Adopted Standard: ISO 20998-2-2013, IDT Regulation (derived from): National Standard Announcement No Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies ultrasonic attenuation spectroscopy for the measurement of the particle size distribution of particles in liquid at low concentrations. In this case, the ultrasonic attenuation spectrum is a linear function of the particle volume concentration, and the interaction between particles is negligible. The scope of this standard includes colloids, low-concentration dispersions and emulsions. Ultrasonic particles typically range in particle size from 10 nm to 3 mm. Particles beyond this range have also been successfully measured. For solid particle suspensions, the typical volume concentration range for the measured particles is typically between 0.1% and 5%, depending on the density ratio of the particles to the dispersion medium, particle size and frequency range. This type of sonication can be used to monitor the dynamic changes in particle size in real time. For emulsions, it can be used to measure higher GB/T 29023.2-2016: Measurement and characterization of particles by acoustic method -- Part 2: Guidelines for linear theory---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Measurement and characterization of particles by acoustic method - Part 2. Guidelines for linear theory ICS 19.120 A28 National Standards of People's Republic of China Ultrasonic Particle Measurement and Characterization Part 2. Linear Theory Criteria Measurementandcharacterization ofparticlesbyacousticmethod- Part 2. Guidelinesforlineartheory (ISO 20998-2..2013, IDT) 2016-02-24 released 2016-06-01 Implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface III Introduction IV 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 4 symbols and abbreviations 2 5 attenuation mechanism (for low concentration system) 3 6 particle size measurement 6 7 Instrument Requirements 7 8 results report 8 Appendix A (informative) Viscous loss model 9 Appendix B (informative) ECAH theory and its limitations 10 Appendix C (informative) semi-empirical model example 12 Appendix D (informative) Iterative fitting 14 Appendix E (informative) The physical properties of the selected material Appendix F (informative) Example of particle size distribution (PSD) measurement Reference 24 ForewordGB/T 29023 "ultrasonic particle measurement and characterization" is divided into three parts. Part 1. Concept and process of ultrasonic attenuation spectroscopy; Part 2. Linear Theory Criteria; Part 3. Non - linear theoretical guidelines. This part is part 2 of GB/T 29023. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part uses the translation method equivalent to ISO . 20998-2..2013 "Ultrasonic particle measurement and characterization Part 2. Linear theory then". This part of the National Particle Characterization and Separation and Screen Standardization Technical Committee (SAC/TC168) proposed and centralized. This part of the drafting unit. Shanghai University of Science and Technology, Chinese Academy of Sciences Institute of Process Engineering, in the machine productivity promotion center, Beijing Coast Hong Meng standard Material Technology Co., Ltd., Dandong Baxter Instrument Co., Ltd., Dandong Dongfang Measurement & Control Technology Co., Ltd. This part of the drafters. Zhou Ji, Su Mingxu, Chen Jun, Li Zhaogong, Yu Fang, Cai Xiaoshu, Dong Qingyun, Li Li.IntroductionIt is well known that ultrasound spectroscopy can be used to measure particle size distribution in colloids, dispersions and emulsions (see [1] [2] [3] [4]). Basic The principle is to measure the ultrasonic attenuation or velocity dependent on the frequency change when the ultrasound passes through the sample. This attenuation spectrum is controlled by the particles in the sample The effect of scattering or absorption of waves is a function of the particle size distribution and concentration of the dispersed particles (see [5] [6] [7]). Once experienced through experience or management On the basis of calculations, the particle size distribution can be determined from the ultrasonic data. Ultrasound technology for dynamic on-line measurement of high concentrations The slurry and the emulsion are very useful. In the past, this test was carried out offline at the Quality Control Laboratory, subject to instrument conditions, and the sample was diluted to detect. In the original The initial concentration was measured using ultrasound on-line without changing the state of the original sample. In addition, dynamic processes (such as flocculation, dispersion, research) Grinding, etc.) for real-time observation ([8]). Test data can be used directly in process control to improve process and product performance. Ultrasonic Particle Measurement and Characterization Part 2. Linear Theory Criteria1 ScopeThis part of GB/T 29023 describes the ultrasonic attenuation spectrum used to measure the particle size distribution of particles in a liquid at low concentrations In this case, the ultrasonic attenuation spectrum is a linear function of the particle volume concentration, and the interaction between the particles can be neglected. This part of the scope Including colloids, low concentration dispersions and emulsions, the typical size of the particle size represented by the ultrasound method ranges from 10 nm to 3 mm, More than this range of particles have been successfully measured. For solid particle suspension systems, the typical volume concentration range of the particles is usually measured 0.1% to 5%, depending on the density ratio of particles and dispersion medium [9,10], particle size and frequency range. Note. see references [9], [10]. This type of ultrasound can be used to monitor the dynamic changes in particle size in real time. For emulsions, it can be used to measure higher concentrations. Although both the ultrasonic attenuation spectrum and the phase velocity spectrum can be used to analyze the particle size distribution of the particles, only ultrasonic attenuation methods are recommended. due to The relative change in the phase velocity caused by the change in particle size is small compared to the average speed, so it is difficult to accurately determine the magnitude of the phase velocity, Warm under the environment. Likewise, it is not recommended to combine the attenuation spectra and the velocity spectrum to measure particle size. The measurement error in the amplitude and phase spectra increases Plus the pathological nature of the problem, reducing the inversion stability.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 29023.1-2012 Ultrasonic method for particle measurement and characterization - Part 1. Concepts and processes of ultrasonic attenuation spectroscopy (ISO 20998.1..2006, IDT) ISO 14488..2007 Particleat materials - Sampling and Sampling samplesplittingforthedeterminationofparticulateproperties3 terms and definitionsGB/T 29023.1-2012 Definitions and the following terms and definitions apply to this document. 3.1 Coefficient of variation The ratio of standard deviation to mean value. 3.2 Dimensionless particle size parameter dimensionlesssizeparameter Represents the dimensionless number of particles, the product of the wave number and the particle radius. 3.3 Particle radius particleradius Particle diameter of one-half. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29023.2-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 29023.2-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 29023.2-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29023.2-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |