Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 26343-2010 English PDF

US$489.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 26343-2010: Technical standard for physical examination for students
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 26343-2010489 Add to Cart 4 days Technical standard for physical examination for students Valid

Similar standards

GB/T 36876   GBZ/T 250   GB 8921   GB 40070   GB/T 17225   

Basic data

Standard ID: GB/T 26343-2010 (GB/T26343-2010)
Description (Translated English): Technical standard for physical examination for students
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: C56
Classification of International Standard: 13.100
Word Count Estimation: 21,294
Date of Issue: 2011-01-14
Date of Implementation: 2011-05-01
Quoted Standard: GB/T 11533; GB/T 16133; WS/T 202; WS288
Regulation (derived from): National Standard Approval Announcement 2011 No.121
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the students form, physiological functions, ENT, surgery, technical requirements for medical and laboratory parameters. This standard applies to ordinary schools, vocational high school and technical school students' health checks, colleges and universities may also refer students to perform health checks.

GB/T 26343-2010: Technical standard for physical examination for students

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical standard for physical examination for students ICS 13.100 C56 National Standards of People's Republic of China Student Health Check Technical Specification Issued on. 2011-01-14 2011-05-01 implementation People's Republic of China Ministry of Health Standardization Administration of China released

Foreword

The Standard Appendix A, Appendix B, Appendix C is a normative appendix. This standard is proposed and administered by the People's Republic of China Ministry of Health. This standard by the People's Republic of China Ministry of Health is responsible for interpretation. This standard was drafted. Hunan Provincial Disease Prevention and Control Center, the Shanghai Municipal Center for Disease Control and Prevention, Public Health, Anhui Medical University Hospital, Hunan Provincial People's Hospital, Shenzhen Center for Disease Control. The main drafters of this standard. Li Guangchun early Pengning Ning, Tao aryl standard, Liu Huilin, Liusi Qing, Chen Xue, Wang Cuilan. Student Health Check Technical Specification

1 Scope

This standard specifies the student morphological, physiological functions, ENT, surgery, medical and technical requirements for laboratory parameters. This standard applies to ordinary primary and secondary schools, vocational high school and technical school students health checks and colleges students may also refer to a health check carried out.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 11533 standard vision chart GB/T 16133 Children in screening abnormal curvature of the spine WS/T 202 children and adolescents refractive testing requirements WS288 tuberculosis diagnostic criteria

3 Configuration of measurement

3.1 Height 3.1.1 Equipment Human altimeter. 0.00 proofread before use, and with a standard steel body correction tape altimeter scale, per meter error no larger than 0.1cm. At the same time, should Check the column and base plate, column and vertical slide board is measured at the connection is tight, loose parts, etc., should be corrected promptly. 3.1.2 Method Choose flat against the wall of the ground horizontal human altimeter, column scale facing the light source. Subject barefoot, standing in attention position Humans altimeter floor, two upper limbs drooping naturally, heels together, toes separated into 60 °, chest and abdomen, head upright, eyes flat front view Side, under the eyes and ears on the edge of the edge of the screen horizontal position between the heel, sacral and two three-point contact with scapular region column. Inspectors are standing on the The right side of the subject, the slide plate measured along the column fell gently until contact with the cranial vertex. Binocular testing personnel should be high when the readings measured with the slide plate. Measurement The amount of error should not exceed ± 0.5cm. 3.1.3 Results Recording Recorded in centimeters, after reading to one decimal place. 3.1.4 Precautions a) measuring slide plate in contact with the cranial vertex, elastic moderate. Head of braids, hair knot should untie, accessories should be removed. B) After completion of the measurement, should be measured immediately slide plate to the highest point, to avoid the subject of other accident trauma. 3.2 Weight 3.2.1 Equipment Lever or portable electronic scales weighing meter. Before use to test its accuracy and sensitivity, calibration with standard weight 50kg and 0.1kg accuracy requirements of error of less than 0.1%, the sensitivity should be able to detect 0.1kg, below standard should be replaced. 3.2.2 Method The scales on a flat, hard surface. Male students to wear shorts and female students to wear shorts, tank tops, countertops central standing scales. Use bars
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 26343-2010_English be delivered?

Answer: Upon your order, we will start to translate GB/T 26343-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 26343-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 26343-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.