Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 25841-2017 English PDF

US$299.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 25841-2017: Guide of protection relaying for 1 000 kV power system
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 25841-2017299 Add to Cart 3 days Guide of protection relaying for 1 000 kV power system Valid

Similar standards

GB/T 38953   GB/T 37155.2   GB/T 19826   GB/T 45648.2   GB/T 25843   

Basic data

Standard ID: GB/T 25841-2017 (GB/T25841-2017)
Description (Translated English): Guide of protection relaying for 1 000 kV power system
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K45
Classification of International Standard: 29.240
Word Count Estimation: 15,117
Date of Issue: 2017-07-31
Date of Implementation: 2018-02-01
Older Standard (superseded by this standard): GB/Z 25841-2010
Quoted Standard: GB/T 14285; GB/T 14598.9; GB/T 14598.10; GB/T 14598.11; GB/T 14598.13; GB/T 14598.14; GB/T 14598.16; GB/T 14598.17; GB/T 14598.18; GB/T 15145; GB/T 17626.8; GB/T 17626.9; GB/T 17626.29; GB/T 20840.2; GB/T 22386; DL/T 364; DL/T 478; DL/T 670; DL/T 720
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the basic criteria for relay protection devices with special requirements for AC kV kV and 1 000 kV substation voltage levels. This standard is used in the field of scientific research, design, manufacture, testing, construction and operation of 1 000kV power system relay protection.

GB/T 25841-2017: Guide of protection relaying for 1 000 kV power system

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Guide of protection relaying for 1 000 kV power system ICS 29.240 K45 National Standards of People's Republic of China Replacing GB /Z 25841-2010 Technical Guidelines for 1000 kV Power System Relay Protection 2017-07-31 Posted 2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 General requirements 2 4 line protection technology requirements 5 5 Transformer Protection Technical Requirements 6 6 bus protection 8 7 circuit breaker protection and reclosing 9 8 remote tripping and over-voltage protection 10 Shunt reactor protection 11 Short lead protection

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is GB /Z 25841-2010 "1000kV Power System Relay Protection Technical Guidelines" revision, and GB /Z 25841- 2010, in addition to editorial changes, the main technical changes are as follows. --- Increasing the other voltage level 1000kV substation relay protection of the special requirements; --- Communication Protocol to delete DL/T 667 requirements, leaving only to meet the requirements of DL/T 860; --- Cancel the central signal contact output requirements; --- 1000kV does not consider the smart station, delete the requirements of electronic transformers; --- For the main line protection, instead of using only the current differential protection, and cancel the corresponding longitudinal distance protection requirements; --- Line protection added to determine the zero sequence compensation factor requirements; --- Line protection of non-full phase oscillation and failure occurred outside the assessment; --- The main transformer, voltage regulator, compensation requirements change prepared separately; --- Increase the on-load tap-changer protection requirements; --- Increase 110kV busbar protection and capacitor protection action and start failure requirements; --- Canceled in accordance with the order of reclosing requirements. Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This standard proposed by the China Electricity Council and centralized. This standard was drafted unit. State Grid Corporation of China State Power Dispatching Control Center, Nanjing NARI insurance Electric Co., Ltd., the State Grid Corporation Division of Ministry of Construction and Communication, China Southern Power Grid Company Power Dispatching Control Center, Huazhong Power Control Center, East China Electric Power Regulatory Center, Zhejiang Power Regulatory Center, Zhejiang Power Maintenance Branch, Shanghai Electric Power Regulatory Center, Anhui Power Regulatory Center, Henan Electric Power Regulatory Center, Shanxi Power Regulatory Center, China Electric Power Research Institute, Jiangsu Electric Power Research Institute, East China Electric Power Design Institute, North China Electric Power Design Institute, Northwest Power Power Design Institute, Jiangsu Electric Power Design Institute, State Power Nanjing Automation Co., Ltd., Beijing Sifang Automation Co., Ltd., Xu relay Gas Co., Ltd. The main drafters of this standard.Li Li, Wang Delin, Liu Qiankuan, Ni Laqin, Liu Yu, Qian Jianguo, Chen Shuiyao, Gan Zhong, Xie Min, Tian Baojiang, Cai Weiwei, Liu Hongtao, Zhan Rongrong, Guo Xiao, Yuan Yubo, Xu Zhenyu, Wu Lijun, She Xiaoping, Ge Dong, Li Youhuai, Lou Yue, Yu Jiang, Wang Xiaoyang, Wang Ye, Ni Chuan Kun. Technical Guidelines for 1000 kV Power System Relay Protection

1 Scope

This standard specifies the exchange 1000kV substation and 1000kV substation voltage level has special requirements of the relay protection device The basic guidelines. This standard applies to 1000kV power system relay protection research, design, manufacture, testing, construction and operation and other fields.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 14285 relay protection and safety automatic device technical regulations GB/T 14598.9 Electrical relays Part 22-3. Measuring relays and protection devices electrical disturbance test Radiated Electromagnetic Field interference test GB/T 14598.10 Electrical relays - Part 22. Measuring relays and protection equipment - Part 22-4 - Electrical disturbance tests Fast transient interference test GB/T 14598.11 Measuring relays and protection equipment Part 11. Auxiliary power supply port voltage dips, short interruptions, changes And ripple GB/T 14598.13 Measuring relays and protection equipment - Part 22-1. Electrical disturbance tests 1MHz burst interference test GB/T 14598.14 Measuring relays and protection equipment - Part 22-2. Electrical disturbance tests Electrostatic discharge test GB/T 14598.16 Electrical relays - Part 25. Electromagnetic emission test of measuring relays and protection devices GB/T 14598.17 Electrical relays - Part 22-6 - Electrical disturbance tests for measuring relays and protection equipment - RF field sensing The immunity to conducted disturbances GB/T 14598.18 Measuring relays and protection devices - Part 22-5 - Electrical disturbance tests Surge immunity test GB/T 15145 transmission line protection devices for general technical conditions GB/T 17626.8 Electromagnetic compatibility test and measurement techniques Power frequency magnetic field immunity test GB/T 17626.9 Electromagnetic compatibility test and measurement techniques pulsed magnetic field immunity test GB/T 17626.29 electromagnetic compatibility test and measurement technology DC power input port voltage dips, short interruptions and voltage changes Immunity test Transformers - Part 2. Current transformers GB/T 22386 Power system transient data exchange common format General technical requirements for DL / T 364 Fiber Channel transmission protection information General technical requirements for DL / T 478 relay protection and safety automatic devices General specification of DL/T 670 busbar protection device DL/T 720 power system relay cabinets, screens general technical conditions General Requirements for DL / T 770 Transformer Protective Devices DL/T 860 (all parts) Substation communication networks and systems DL/T 866 Current Transformer and Voltage Transformer Selection and Calculation Guide
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 25841-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 25841-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 25841-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 25841-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.