GB/T 25300-2010 English PDFUS$154.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25300-2010: Resistance welding equipment -- Particular specifications applicable to transformers with one secondary winding for multi-spot welding, as used in the automobile industry Status: Valid
Basic dataStandard ID: GB/T 25300-2010 (GB/T25300-2010)Description (Translated English): Resistance welding equipment -- Particular specifications applicable to transformers with one secondary winding for multi-spot welding, as used in the automobile industry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: J64 Classification of International Standard: 25.160.30 Word Count Estimation: 8,833 Date of Issue: 2010-11-10 Date of Implementation: 2011-05-01 Quoted Standard: GB/T 25299; GB/T 25301 Adopted Standard: ISO 12166-1997, IDT Regulation (derived from): National Standard Approval Announcement 2010 No.8 (Total No.163) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the technical requirements for special transformers special in its range of applications. Is complementary to GB/T 25301 (ISO 5826) (applicable to general technical condition of all transformers) of. Unless otherwise specified, GB/T 25301 (ISO 5826) in this standard has not been revised technical requirements still apply. This standard applies to the automotive industry for use with a secondary coil of multi- spot welding transformer. These transformers can replace GB/T 25299 (ISO 7284) of the transformer having a current control, they can also substitute GB/T 25299 (ISO 7284) using only one secondary winding of the transformer. GB/T 25300-2010: Resistance welding equipment -- Particular specifications applicable to transformers with one secondary winding for multi-spot welding, as used in the automobile industry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Resistance welding equipment. Particular specfications applicable to transformers with one secondary winding for multi-spot welding, as used in the automobile industry ICS 25.160.30 J64 National Standards of People's Republic of China Having a resistance welding equipment used in the automotive industry Multi-spot welding transformer secondary winding special technical conditions welding, asusedintheautomobileindustry (ISO 12166.1997, IDT) Issued on. 2010-11-10 2011-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard is identical with ISO 12166.1997 "welding equipment used in the automotive industry has a secondary coil becomes multi-spot welding Pressure Particular technical conditions. " The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee Welder (SAC/TC70) centralized. This standard was drafted. Shenzhen Ruiling Industrial Co., Ltd., Guangzhou Hing Electric Co., Ltd., China Quality Certification Center, Chengdu Tripartite Electric Co., Ltd., Kai Erda Group Limited. The main drafters of this standard. Qiu light, Liu Guoying Secretary Lifeng, Puyou Dong, Wang Wei, Wang Shikai. Having a resistance welding equipment used in the automotive industry Multi-spot welding transformer secondary winding special technical conditions1 ScopeThis standard specifies the special transformer special technical requirements within their scope of application, is GB/T 25301 (ISO 5826) (applicable to General technical conditions for all transformers) supplement. Unless otherwise specified, GB/T 25301 (ISO 5826) in this standard has not been revised technical requirements still apply. This standard applies to the automotive industry for use in a secondary coil having a multi-spot welding transformer. These transformers can replace GB/T 25299 (ISO 7284) having a current control transformers, it can also replace GB/T 25299 (ISO 7284) using only A secondary winding of the transformer. Compliance with this standard transformer should be designed to. a) secondary welding circuit allows individual control and regulation; b) can meet the requirements of this standard two transformers replace GB/T 25299 a transformer (ISO 7284) as specified. Note. After consultation between the manufacturer and the user of this standard can be used for other industrial sectors multi spot welding transformers or other types of welding. GB/T 25301 (ISO 5826) in each case are suitable.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 25299 resistance welding equipment for the automobile industry has special technical conditions two independent multi-spot welding transformer coil Member (GB/T 25299-2010, ISO 7284.1993, IDT) GB/T 25301 welding equipment general technical conditions applicable to all transformers (GB/T 25301-2010, ISO 5826. 1999, IDT) Type third transformer This standard covers has a secondary load voltage U20, secondary reference and continuous current I2P continuous output power of SP and/or 50% Duty cycle when the input power of S50 and other characteristics, with the following types of a secondary winding of the transformer. Transformer secondary voltage can be only one (see Table 1) or on the primary side with a set of connectors to select the secondary voltage (see Table 2). Table 1 is only a secondary voltage transformer type electrical characteristics U20/V I2P/kA SP/kVA S50/kVA 7.1 4.0 28 40 10.0 4.5 45 63 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25300-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 25300-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 25300-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25300-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |