GB/T 24835-2018 English PDFUS$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24835-2018: Regulation of operation and maintenance for 1100kV gas-insulated metal-enclosed switchgear Status: Valid
Basic dataStandard ID: GB/T 24835-2018 (GB/T24835-2018)Description (Translated English): Regulation of operation and maintenance for 1100kV gas-insulated metal-enclosed switchgear Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K43 Classification of International Standard: 29.240 Word Count Estimation: 14,124 Date of Issue: 2018-12-28 Date of Implementation: 2019-07-01 Older Standard (superseded by this standard): GB/Z 24835-2009 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 24835-2018: Regulation of operation and maintenance for 1100kV gas-insulated metal-enclosed switchgear---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Regulation of operation and maintenance for 1100kV gas--insulated metal--enclosed switchgear ICS 29.240 K43 National Standards of People's Republic of China Replace GB /Z 24835-2009 1100kV gas insulated metal-enclosed switchgear Operation and maintenance procedures Published on.2018-12-28 2019-07-01 implementation State market supervision and administration China National Standardization Administration issued ContentForeword I 1 Scope 1 2 Normative references 1 3 Safety requirements for operation and maintenance 1 4 Technical requirements for operation and maintenance 4 5 Quality Supervision of SF6 Gas 7 6 Technical requirements for disassembly and repair 7ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB /Z 24835-2009 "1000kV gas insulated metal-enclosed switchgear operation and maintenance procedures", and The main changes compared with GB /Z 24835-2009 are as follows. --- Removed "terms and definitions" (see Chapter 3 of the.2009 edition); --- Removed the "auxiliary system (air compressor system for pneumatic mechanisms)" (see 7.4.6 of the.2009 edition); --- Removed the general flow chart of GIS decomposition and maintenance (see 7.7 of.2009 edition); --- Removed the "Decomposition Check" (see 7.8 of the.2009 edition); --- Removed the precautions for the use of gas recovery units (see 7.9 of the.2009 edition); --- Removed the precautions for storage of gas cylinders (see 7.10 of the.2009 edition); --- Remove the precautions for the use of adsorbents (see 7.11 of the.2009 edition); --- Deleted the organization notes after disassembly and repair (see 7.12 of.2009 edition); --- Removed the "Selection and Test of Grease and Sealant" (see 7.13 in.2009); --- Removed the "Technical Requirements for Sealing and Disassembling" (see 7.14 in.2009); --- Removed "spare parts and special tools" (see Chapter 9 of the.2009 edition); --- Removed the "positioning and detection methods for discharge faults" (see Appendix A of the.2009 edition); --- Revised the basis for the disassembly and repair of the circuit breaker (see 6.1.1, 4.4.4.1 of the.2009 edition); ---Modified the dismantling and maintenance project of the circuit breaker in GIS, and deleted the "pneumatic operating mechanism" (see 6.2.1.2, 7.4.1.2 of.2009 edition); --- Revise the technical requirements for physical examination and repair, and incorporate the "test" (see the 8th edition of.2009) into the "experiment after disassembly and repair" (see 6.7). This standard was proposed by the China Electricity Council. This standard is under the jurisdiction of the National UHV AC Transmission Standardization Technical Committee (SAC/TC569). This standard was drafted. State Grid Corporation, China Electric Power Research Institute Co., Ltd., State Grid Shanghai Electric Power Company, State Grid Fujian Province Power Co., Ltd. The main drafters of this standard. Han Xiancai, Yan Xiaoyu, Xu Lingling, Peng Jiang, Zhang Hejun, Wang Ninghua, Wang Chengyu, Liu Zhaolin, Li Jinzhong, Wu Chao, Liu Xueli, Tang Hao, Lin Yizhen, Fu Chenxi. The previous versions of the standards replaced by this standard are. ---GB /Z 24835-2009. 1100kV gas insulated metal-enclosed switchgear Operation and maintenance procedures1 ScopeThis standard specifies the project, content and technology of 1100kV gas insulated metal-enclosed switchgear (hereinafter referred to as GIS) operation and maintenance. Claim. This standard applies to rated voltage 1100kV AC GIS (including HGIS).2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 5832.1 Determination of trace moisture - Part 1 . Electrolysis GB/T 5832.2 Determination of trace moisture - Part 2. Dew point method GB/T 11023 High-voltage switchgear sulphur hexafluoride gas seal test guide GB/T 12022 industrial sulfur hexafluoride GB/T 24846-2018 1000kV AC electrical equipment preventive test procedures Guide for on-site withstand voltage and insulation test of DL/T 555 gas-insulated metal-enclosed switchgear3 Safety requirements for operation and maintenance3.1 Safety technical measures during GIS operation 3.1.1 Security protection of GIS room The security protection of the GIS room is as follows. a) According to GB 8958GIS, the oxygen content in indoor air should be greater than 19.5% or the concentration of SF6 gas should not exceed 1000 μL/L. (or 6g/m3); b) The GIS indoor should be equipped with an automatic detection and alarm device for air oxygen content or SF6 gas concentration; c) Protective equipment such as gas masks, protective clothing and plastic gloves should be provided at the entrance and exit of the GIS room; d) The GIS room shall be equipped with special fire protection facilities in accordance with the relevant provisions of fire protection; e) All access holes in the GIS room shall be sealed with fireproof materials; f) The GIS room should be equipped with adequate ventilation and exhaust devices; g) When entering the GIS indoor cable trench or low recess, the oxygen content or SF6 gas concentration should be measured, and the safety can be confirmed before entering; h) In order to prevent accidents in single-person operations, access to these areas requires supervision. 3.1.2 Ventilation technical requirements for GIS room The GIS room should be equipped with a powerful ventilation device, and the air outlet should be placed at the bottom of the room. The GIS room where the operators frequently enter and exit, each class should be ventilated at least once (15min); for indoor places where the staff does not frequently enter and exit, Check the ventilation facilities regularly. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24835-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 24835-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 24835-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24835-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |