GB/T 24392-2009 English PDFUS$314.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24392-2009: Standard method of measurement of lamp cap temperature rise Status: Valid
Basic dataStandard ID: GB/T 24392-2009 (GB/T24392-2009)Description (Translated English): Standard method of measurement of lamp cap temperature rise Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K74 Classification of International Standard: 29.140.10 Word Count Estimation: 16,118 Date of Issue: 2009-09-30 Date of Implementation: 2010-02-01 Quoted Standard: GB 14196 Adopted Standard: IEC 60360-1998, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 10 of 2009 (No. 150 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies cap temperature rise of a standard measurement method, suitable for detecting incandescent and gas discharge lamps meets the temperature rise limit. GB 14196 listed in a specific type of lamp temperature limit. This standard relates to the lamp test lamp test methods and technical requirements, this type of lamp is equipped with different types of screw caps and bayonet cap. This method has been widely used to test the incandescent lamp, but its use is not limited to incandescent lamps. GB/T 24392-2009: Standard method of measurement of lamp cap temperature rise---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Standard method of measurement of lamp cap temperature rise ICS 29.140.10 K74 National Standards of People's Republic of China GB/T 24392-2009/IEC 60360.1998 The method of measuring cap temperature rise (IEC 60360.1998, IDT) Posted 2009-09-30 2010-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ Introduction Ⅱ 1 Overview 1 1.1 Scope 1 1.2 Normative references 1 2 Definitions 1 2.1 1 cap temperature rise 2.2 equilibrium temperature 1 General conditions for measurement of 3 1 3.1 Aging and stability 1 3.2 Supply Voltage 1 3.3 test chamber at ambient temperature and the reference temperature 1 4 2 test requirements 4.1 Test Chamber 2 4.2 Method 2 suspension 5 Test lamp socket 2 5.1 General structure 2 5.2 Test lampholder sleeve material requirements 3 5.3 spring material claim 3 6 Power Wire 3 Thermocouple 7 3 7.1 material 3 7.2 Connection 3 7.3 Test connection with lamp holder sleeve 3 7.4 Instrument 4 7.5 Calibration 4 8 lamp and lamp holder installation test in the chamber of 4 9 measuring cap temperature rise of 4 GB/T 24392-2009/IEC 60360.1998ForewordThis standard is identical with IEC 60360.1998 "Measurement cap temperature rise" (in English). This standard is equivalent translation IEC 60360.1998. For ease of use, this standard made the following editorial changes. a) "The technical specifications" replaced by "this standard"; b) Remove IEC 60360.1998 Foreword; c) For IEC 60360.1998 and other international standards have been cited as identical with our standard, our present standard reference These national standards or industry standards corresponding to international standards in place, the rest is not tantamount to the adoption of standard international standards, This standard are a direct reference (see 1.2 of this standard). The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee of electrical lighting (SAC/TC224) centralized. This standard was drafted. Zhejiang Institute of Standardization, Beijing Institute of electric light. The main drafters of this standard. Chen Zili, Jiang Jianping, Zhao Xiurong, Jiang Shan, Duan Yan Fang. GB/T 24392-2009/IEC 60360.1998IntroductionCap temperature rise depends largely on the lamp assembly and lamp conditions. Accordingly, it is necessary to test the lamp holder according to the criteria used Compared with bare measuring cap temperature rise, the temperature rise measured standard test lampholder, has the following advantages. --- Closest to the actual operating conditions; --- Improving the repeatability, due to the smaller cap material, surface roughness and surface conditions on (lamp material, surface roughness and surface The same conditions of actual operating conditions less affected); --- All parts of the lamp cap temperature equilibrium, given from a light fixture to a more complete overall heat transfer; --- Shorten the measurement time, because the thermocouple can be permanently fixed to the test holder. GB/T 24392-2009/IEC 60360.1998 The method of measuring cap temperature rise1 Overview1.1 Scope Standard measurement method described in this standard cap temperature rise, suitable for detecting tungsten and gas discharge lamps meets the temperature rise limit. GB 14196 are listed lamp type temperature limit. This standard relates to the technical requirements and test methods for test lamp base of the lamp, this type of lamp is equipped with different types of screw caps and bayonet lamp head. This method has been widely used to test the incandescent lamp, but its use is not limited to incandescent lamps. 1.2 Normative references The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 14196 (all parts) incandescent safety requirements (IEC 60432, IDT)2 DefinitionsThis standard uses the following terms and definitions. 2.1 Under the conditions specified in this standard, the standard test lampholder fitted cap measured surface temperature rise. 2.2 After fully lighted lamp, a standard test lampholder reached steady-state temperature. Note. The measurement accuracy should be ± 1 ℃. General Condition 3 of Measurement 3.1 Aging and stability Before measurement, the lamp does not have to be old mill. When the equilibrium temperature test chamber, the lamp should reach full stability. 3.2 Supply Voltage a) directly connected to the power supply of the lamp, when measured using the rated voltage, the power supply voltage should be stabilized in the range of ± 0.5%; b) by the power supply is connected to the ballast lamp ballast should be measured using the rated voltage of the power supply voltage should be stable at ± 0.5% In the range. This should be measured using a reference ballast or ballast finished, finished with a reference ballast impedance in current calibration Ballast error should be within ± 1% range. If the lamp voltage range marker should be used in the test procedures specified in GB 14196, other publications as otherwise provided by the program except. 3.3 test chamber at ambient temperature and the reference temperature Except provisions), namely. the test chamber temperature during the measurement should be kept within this range in order to ensure effective measurement results. Measurements taken 4.1 with a special chamber, wherein the chamber to ensure that the ambient temperature reaches substantially constant. GB/T 24392-2009/IEC 60360.1998 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24392-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 24392-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 24392-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24392-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |