GB/T 23908-2009 English PDFUS$229.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 23908-2009: Non-destructive testing -- Practice for ultrasonic pulse-echo straight-beam testing by the contact method Status: Valid
Basic dataStandard ID: GB/T 23908-2009 (GB/T23908-2009)Description (Translated English): Non-destructive testing -- Practice for ultrasonic pulse-echo straight-beam testing by the contact method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: J04 Classification of International Standard: 19.100 Word Count Estimation: 10,116 Date of Issue: 2009-05-26 Date of Implementation: 2009-12-01 Quoted Standard: GB/T 23901.1; GB/T 23901.2; GB/T 23901.5; GB/T 5616; GB/T 9445; GB/T 12604.1; GB/T 20737; JB/T 9214 Adopted Standard: ASTM E114-1995 (2001), MOD Regulation (derived from): PRC National Standard Approval Announcement 2009 No.7 (Total No.147) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the probe and the probe was seized direct contact with the material should pick longitudinal wave pulse-echo ultrasonic testing methods. This standard applies to custom inspection process measurement procedures. GB/T 23908-2009: Non-destructive testing -- Practice for ultrasonic pulse-echo straight-beam testing by the contact method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Non-destructive testing.Practice for ultrasonic pulse-echo straight-beam testing by the contact method ICS 19.100 J04 National Standards of People's Republic of China Non - destructive testing Method of direct detection of contact ultrasonic pulse echo 2009-05-26 release 2009-12-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released ForewordThis standard is modified using ASTME114-95 (2001) "Contact ultrasonic pulse echo direct detection method" (English version). This standard is redrafted according to ASTME114-95. Taking into account our national conditions, in the use of ASTME114-95, the standard made some changes. The technical differences are as follows. --- the normative reference document ASTME543 to our standard GB/T 5616; --- Standardized reference documents SNT-TC-1A, ANSI/ASNTCP-189, NAS-410 to China's standard GB/T 9445; --- the normative reference document ASTME1316 to our standard GB/T 12604.1 and GB/T 20737; --- the normative reference document ASTME317 to our standard JB/T 9214; --- Remove ASTME114-95 of 1.3, 1.4, Table 1 and Chapter 12. For ease of use, this standard has also made the following editorial changes. The word "this method" is changed to "this standard"; --- replace the value of the imperial unit with the value of the international unit system; - insert the lead in GB/T 1.1-2000 in Chapter 2; --- According to the format requirements specified in GB/T 1.1-2000, refer to Chapter 1, Chapter 2, Chapter 4, Chapter 6, Chapter 9, Chapter 10 and Some of the bars in Chapter 11 are modified. This standard is proposed by the National Committee for the Standardization of Non-destructive Testing (SAC/TC56). The drafting of this standard. Shanghai Suzhou US Kodak Detection Equipment Co., Ltd., Shanghai Materials Research Institute, Shanghai Engineering Materials Application Evaluation Key Laboratory, Changzhou Ultrasonic Electronics Co., Ltd., Shandong Jining Mold Factory, Shanghai Shangmu Electromagnetic Equipment Co., Ltd., Shanghai Pan Asia Nondestructive Testing Technology Co., Ltd., Shanghai Shangmu Engineering Materials Testing Co., Ltd., VESTAS Wind Technology (China) Co., Ltd. Shanghai Branch. The main drafters of this standard. Gui Gensheng, Jin Yufei, Li Li, Pan Zhenxin, Wei Zhongrui, Mi Zhongyu, Zhao Cheng, Xiong Shubing, Non - destructive testing Method of direct detection of contact ultrasonic pulse echo1 ScopeThis standard specifies the probe and the test material in direct contact with the direct probe longitudinal wave pulse reflection ultrasonic detection method. This standard applies to the development of testing procedures.2 normative reference documentsThe terms of the following documents are hereby incorporated by reference into this standard. Whichever is the date of the reference file, which is followed by all (Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard Whether you can use the latest version of these files. For undated references, the latest edition applies to this standard. GB/T 5616 Guidelines for non - destructive testing GB/T 9445 non-destructive testing personnel qualification and certification (GB/T 9445-2008, ISO 9712..2005, IDT) GB/T 12604.1 Non-destructive testing Terminology Ultrasonic testing (GB/T 12604.1-2005, ISO 5577..2000, Non-destructivetesting-Ultrasonicinspection-Vocabulary, IDT) GB/T 20737 Non-destructive testing - General terms and definitions (GB/T 20737-2006, ISO /T S18173..2005, IDT) Test Method for Performance Test of JB/T 9214 Type A Pulse Reflective Ultrasonic Flaw Detection System3 terms and definitionsThe terms and definitions established in GB/T 12604.1 and GB/T 20737 apply to this standard.4 Overview4.1 Institutional requirements The institutions or units that carry out the inspection according to this standard shall comply with the relevant requirements of GB/T 5616 or equivalent standards and regulations. 4.2 Personnel Qualification The personnel who carry out the inspection according to this standard shall be qualified and certified according to the system agreed by GB/T 9445 or the parties to the contract, The principal or his agent conducts professional training and operational authorization. 4.3 detection content The contents of the test should be clearly defined in the parties' agreement. 4.4 Detection timing The timing of the inspection should be clearly defined in the agreement between the parties. 4.5 Assessment criteria The criteria for assessing the acceptance of ultrasonic signals and workpieces should be clearly defined in the parties' agreements.5 meaning and use5.1 A series of electrical pulses are applied to the piezoelectric wafer (transducer) to convert the mechanical energy in the form of a nominal frequency pulse wave. Transducer Is fixed in a housing so that the wave can enter the material through a suitable wear-resistant protective film and coupling agent. Transducers, housings, wear films and electricity Gas connector, etc. to form a probe. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 23908-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 23908-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 23908-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 23908-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |