Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 23683-2009 English PDF

US$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 23683-2009: Method of testing flow capacity of refrigerant capillary tubes
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 23683-2009279 Add to Cart 3 days Method of testing flow capacity of refrigerant capillary tubes Valid

Similar standards

GB/T 22068   GB/T 25127.1   GB/T 25127.2   GB/T 23681   GB/T 23682   GB/T 23680   

Basic data

Standard ID: GB/T 23683-2009 (GB/T23683-2009)
Description (Translated English): Method of testing flow capacity of refrigerant capillary tubes
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: J73
Classification of International Standard: 97.130.20
Word Count Estimation: 12,128
Date of Issue: 2009-04-17
Date of Implementation: 2009-11-01
Quoted Standard: JJG 272-2007; JJG 614-2004
Adopted Standard: ANSI/ASHRAE 28-1996 (RA2006), MOD
Regulation (derived from): PRC National Standard Approval Announcement 2009 No.6 (Total No.146)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies two laboratory test methods refrigerant capillary flow. That traditional methods and alternative methods. Used to determine the regulating effect of the refrigerant in the refrigeration system of the capillary flow. Both methods are used with dry nitrogen to provide comparable results. Such as the use of electronic equipment, the choice of an alternative method is more convenient. Standard Test Method for by the flow characteristics of the capillary can be drawn from the refrigerant. But the results obtained do not represent the actual characteristics of the refrigerant flowing in the refrigerant cycle. This standard does not specify capillary diameter tolerances and deviations nitrogen flow requirements. It is recommended that the test results are given an acceptable deviation range.

GB/T 23683-2009: Method of testing flow capacity of refrigerant capillary tubes

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Method of testing flow capacity of refrigerant capillary tubes ICS 97.130.20 J73 National Standards of People's Republic of China Standard Test Method for capillary flow of the refrigerant Posted 2009-04-17 2009-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This revised standard adopts the American National Standards Institute/American Society of Heating Refrigeration and Air Conditioning Engineers Standard ANSI/ASHRAE Standard28-1996 (RA2006) "Standard Test Method for capillary flow of the refrigerant." The Standard made the following technical corrections. --- To comply with China's national conditions, the paper tests the standard conditions of 21 ℃ to 20 ℃, the modified reg place as follows. Chapter 4 d), 5.2,6.3 and 7.1 Note, Qs, Chapter 10 of the f 7.2), Qs 11.6, Chapter 12; --- To comply with the provisions of the barometer test, "the American Society of Mechanical Engineers standard ASMEPerformance referenced in Chapter 4 TestCodes, PTC19.2-1987 (R2004), PressureMeasurement "to Chinese National Standard" JJG272- 2007 "aneroid barometer and Aneroid test procedures" and JJG614-2004 "second-class standard mercury barometer test Order "." The editorial changes made the following standard. --- This standard ASHRAE deleted preface; --- The standard Chapter 1 contains the ANSI/ASHRAEStandard28-1996 (RA2006) of Chapters 1 and 2, the present Standard Chapter 2 of the new "normative references" other sections the same number as the original standard; "." --- With a decimal point instead of a comma as the decimal point, ""; --- The standard delete the original standard in English units, the uniform application of the International System of Units. The standard proposed by the People's Republic of China Ministry of Commerce. This standard by the National Standardization Technical Committee refrigeration (SAC/TC119) and focal point responsible for the interpretation. This standard was drafted. China Refrigeration Institute, Xi'an Jiaotong University, the National Commercial Refrigeration Equipment Quality Supervision and Inspection Center. The main drafters of this standard. Yang Fan, Li Liansheng, Liu Xiaopeng, Wang Wei, Xiao Yang. Standard Test Method for capillary flow of the refrigerant

1 Scope

This standard specifies two laboratory refrigerant capillary flow test method, namely the traditional methods and alternative methods for determining the refrigeration Systems regulate the refrigerant by capillary flow. Both methods use dry nitrogen to provide comparable results. Such as the use of electricity Child device, the choice of an alternative method is more convenient. By standard test methods can be drawn from the capillary flow characteristics of refrigerant. But come The result does not represent the actual flow characteristics of refrigerant in the refrigeration cycle. The standard deviation is not specified capillary diameter tolerances and nitrogen flow requirements, it is recommended that the test results are given acceptable deviation range.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. JJG272-2007 aneroid barometer Aneroid and verification procedures JJG614-2004 second-class standard mercury barometer test procedures

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 In the refrigeration system for adjusting the refrigerant flow and completion of a small-diameter tube throttling process between the condenser and the evaporator, and through Often the inner diameter as small as 0.50mmID. 3.2 Volume flow, the unit in liters per second (L/s) represented, equivalent to a predetermined pressure at the inlet and outlet pressure is standard atmospheric pressure Mass flow of dry nitrogen (101.325 KPa .. absolute pressure) is used. Means a conventional method 4 Test apparatus according to the conventional method of FIG. 1 is arranged. Means are described with the basic measuring instrument (e.g., a thermometer, a pressure gauge), e.g. There are more sophisticated instruments to meet this standard requires the measurement accuracy, can be used. The basic components of the device comprises. a) Dry nitrogen gas supply means (1), providing a minimum pressure of 850 kPa gauge pressure, the maximum temperature of the dew point of -32 ℃ dry nitrogen; b) a filter (2), for removing solid and liquid impurities may be ignored in the nitrogen gas supply line; c) pressure regulator (3) for causing any test pressure within 15kPa ~ 700kPa gauge pressure ranges remain stable during the test Set (± 5% or ± 7kPa even smaller); d) thermostat coil (4) (if necessary), to maintain the same test sample into the ambient temperature and nitrogen means, it should be 20 ℃ ± 3 ℃; e) temperature measuring means (5) with an accuracy of ± 0.3 ℃, should be installed to ensure the temperature sensing device is immersed in a nitrogen stream, to accurately measure the flow Temperature nitrogen; f) pressure measuring instruments (6), the maximum range for the gauge pressure 175kPa, accuracy is ± 0.7kPa or less; g) pressure measuring instruments (7), the measurement of the degree of 2kPa or less, the measurement range of the gauge pressure 175kPa ~ 700kPa; h) sealing means (8) for the test sample (9) is connected to a nitrogen gas stream, the connection should not be increased fluid resistance;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 23683-2009_English be delivered?

Answer: Upon your order, we will start to translate GB/T 23683-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 23683-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 23683-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.