Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 22382-2017: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above Status: Valid GB/T 22382: Historical versions
Basic dataStandard ID: GB/T 22382-2017 (GB/T22382-2017)Description (Translated English): Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K43 Classification of International Standard: 29.130.10 Word Count Estimation: 22,280 Date of Issue: 2017-07-12 Date of Implementation: 2018-02-01 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 22382-2017: Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above ICS 29.130.10 K43 National Standards of People's Republic of China Replace GB/T 22382-2008 Rated voltage 72.5kV and above gas insulated metal The direct connection between the enclosed switchgear and the power transformer (IEC 62271-211..2014, High-voltageswitchgearandcontrolgear-Part 211. Directconnectionbetweenpowertransformersandgas-insulated metal-enclosedswitchgearforratedvoltagesabove52kV, MOD) 2017-07-12 release.2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface III 1 Overview 1 1.1 Scope 1 1.2 Normative references 1 2 normal and special conditions of use 1 3 Terms and definitions 1 4 rated 3 4.1 Overview 3 4.2 Rated voltage (Ur) 3 4.3 Rated insulation level 3 4.4 Rated frequency (fr) 3 4.5 Rated current (Ir) and temperature rise 3 4.6 Rated short time withstand current (Ik) and rated heat short current (Ith) 3 4.7 Rated peak withstand current (Ip) and rated dynamic current (Id) 3 4.8 Rated short-circuit duration (tk) and rated duration (tth) 4 4.9 Rated filling pressure for insulating gas (pre) 4 Design and Structure 5.1 Overview 4 5.2 Pressure tolerance requirements 4 5.3 Gas and vacuum seal 4 5.4 Mechanisms acting on the connection interface 4 5.5 Mechanical force acting on the casing flange 5 5.6 Horizontal and vertical displacement 5 5.7 vibration 6 5.8 Standard dimensions and tolerances 6 6 type test 6 6.1 Overview 6 6.2 Insulation test 7 6.3 Cantilever load tolerance test 7 6.4 Gas Seal Test 7 7 factory test 7 7.1 Overview 7 7.2 External pressure test of casing 8 7.3 Seal test 8 8 Selection of guidelines 8 9 Information provided with inquiries, tenders and orders Code of transportation, storage, installation, operation and maintenance 11 security 8 Impact of the product on the environment Appendix A (Normative Appendix) Supplier Boundary 15 Figure 1 Typical connection between gas-insulated metal-enclosed switchgear and power transformer 9 Figure 2 Typical dimensions for a direct connection between a gas-insulated metal-enclosed switchgear and a power transformer 10 Figure 3 Typical connection of a three-phase power transformer with a single-phase gas-insulated metal-enclosed switchgear transformer Tolerance 12 Figure 4 Typical connection of three-phase power transformers with three-phase gas-insulated metal-enclosed switchgear Transformer Tolerances 13 Table 1 Moment and force acting on casing flange and transformer 5 Table 2 Standard size 11 Table 3 Typical connection of a three-phase power transformer with a single-phase gas-insulated metal-enclosed switchgear transformer Tolerance 14 Table 4 Typical connection of three-phase power transformers with three-phase gas-insulated metal-enclosed switchgear Transformer Tolerances 14 Table A.1 The boundaries of the supplier (see Figure 1) ForewordThis standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 22382-2008 "Rated voltage 72.5kV and above Gas-insulated metal-enclosed switchgear and power transformer Direct connection between devices, "compared with GB/T 22382-2008, the main technical changes are as follows. --- the range of "three-phase direct connection" and "transformer"; - terms and definitions increase the "insulation connection" and "Platts density"; - rated "rated frequency fr", "rated heat short-time current Ith", "rated dynamic current" and "rated duration" Between tth "; - "gas and vacuum seals" and "horizontal and vertical displacements" are added to the design and construction; - "Standard size and special requirements" in the design and structure to "Standard size and tolerances"; --- type test to increase the "three-phase shell transformer connection insulation test" and "gas seal test"; - an increase in the "impact of products on the environment" chapter; --- Table 1 adds the "rated voltage 800kV" role in the casing flange and the transformer torque and force on the relevant parameters; - Table 2 adds the relevant parameters for the rated lightning impulse withstand voltage (peak) 800kV standard size. This standard uses the re-drafting method to modify IEC 62271-211..2014 "High Voltage Switchgear and Controlgear Part 211. Amount Fixed voltage above 52kV gas insulated metal-enclosed switch equipment and power transformer direct connection between the ". The technical differences between this standard and IEC 62271-211..2014 are as follows. --- on the normative reference documents, this standard has made a technical differences in the adjustment to meet China's technical conditions, adjust the situation The situation is reflected in the 1.2 "normative reference document", the specific adjustments are as follows. Replace IEC 60076 (see 6.1, A.1) with GB/T 1094 with an international standard; Replace IEC 60050-471..2007 (see 3.1/3.2) with GB/T 2900.8-2009 equivalent to the international standard; • Replace the IEC 60137Ed.6.0 with the modified GB/T 4109-2008 with international standard (see Chapter 4, 5.4, 5.5, Chapter 9); Replace IEC 62271-203 (see 4.3, 4.5, 5.2, 5.3) with GB/T 7674-2008 with an international standard; • Replace IEC 62271-1..2007 with GB/T 11022-2011 with international standard modification (see Chapter 2, Chapter 3, Chapter 4, Chapter 6, Chapter 7, Chapter 10, Chapter 11, Chapter 12); Replace IEC 62271-2..2003 (see 5.4) with GB 13540-2009 with international standard modification; --- According to the actual situation of China's power grid, remove the IEC 62271-211..2014 rated frequency of 60Hz of the relevant content (see 1.1); --- Remove the rated voltage value independent of our grid, according to the voltage listed in GB/T 11022-2011. But right 1100kV of this connection device, because the relevant requirements are not yet clear, so this part of the standard temporary vacancy (see 4.2); - "The values and characteristics of the non-linear resistor shall be determined by the switchgear manufacturer" in Chapter 5 of IEC 62271-211..2014 To go because it can not be determined unilaterally by the switchgear manufacturer; --- IEC 62271-211..2014 Figure 2 in the size, shape and position tolerance, the reference method according to China's mechanical drawing standards were modified. In order to ensure the sealing performance, the surface roughness of the sealing surface in the figure is changed from Ra to --- Based on IEC 62271-211..2014, the contents of the table in Figure 2, according to China's relevant standards, the table of the rated lightning shock Withstand voltage (peak) specifically as follows. rated voltage 72.5kV when the 325kV, 380kV; rated voltage 126kV For the 550kV; rated voltage 252kV when the 1050kV; rated voltage 363kV when the 1175kV; rated voltage 550kV when the 1550kV; rated voltage 800kV 2100kV. And the size of the table according to our mechanical drawing The standard note was modified. Compared with IEC 62271-211..2014, this standard has been modified as follows. - change the rated voltage in the heading IEC 62271-211..2014 from "above 52kV" to "72.5kV and above"; - move the 5.1 "supplier boundary" of IEC 62271-211..2014 to Appendix A of this standard; - move the standard size and tolerances of Chapter 8 of IEC 62271-211..2014 to 5.8 of this standard; Figure 1 Split the cost of Figure 1 and Table A.1, Figure 2, Figure 3 and Figure 4 split the cost of the standard of IEC 62271-211..2014 Figure 2, Figure 3 and Figure 4 and Table 2, Table 3 and Table 4. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This standard is proposed by China Electrical Equipment Industry Association. This standard by the National High Voltage Switchgear Standardization Technical Committee (SAC/TC65) centralized. The drafting unit. New Northeast Electric Group High Voltage Switchgear Co., Ltd., Xi'an High Voltage Electric Appliance Research Institute Co., Ltd., Xi'an West Electric switch Electric Co., Ltd., Xi'an West high-voltage switch limited liability company, the machinery industry high-voltage electrical equipment quality testing center, special power Shenyang Electric Technology Research Institute Co., Ltd., Beijing North Electric Co., Ltd., TBEA Shanghai High Voltage Switch Co., Ltd., ABB (China) Co., Ltd., Sunrise Group Co., Ltd., Xiamen ABB High Voltage Switchgear Co., Ltd., Zhejiang Switchgear Co., Ltd., Zhejiang Electric Manufacturing Co., Ltd., Pinggao Group Co., Ltd., Shandong Taikai High Voltage Switchgear Co., Ltd., Yihe Electric Group Co., Ltd. Haisi source high voltage switchgear. The main drafters of this standard. Wu Wenhai, Zhang Meng, Tian Enwen, Chen Guoshun, Zhang Shi, Meng Di, Dai Chuanling, Yuan Fuxing, Zhang Jinbo, Li Qiang, HOU Ping-yin, WANG Chuan-qing, YANG Zhen-jie, ZHANG Shu, YIN Hong-yan, SUN Rong-chun, WANG Song, FAN Jian-rong, LIN Ai-min, GAO Er-ping, ZHOU Qing- Yan Guanxing, Wang Xiangke, Wang Jiancheng, Kong Xiangchong, Yuan Zhibing. This standard replaced the previous version of the standard release. --- GB/T 22382-2008. Rated voltage 72.5kV and above gas insulated metal The direct connection between the enclosed switchgear and the power transformer1 Overview1.1 Scope This standard specifies the rated voltage of 72.5kV and above, rated frequency of 50Hz gas-insulated metal-enclosed switchgear and power The direct connection between the transformer using the conditions of use, rating, design and structure, test, with the inquiry, tender and order to provide information, shipped Transportation, storage, installation, operation and maintenance of the rules, the impact of the product on the environment, the supply side of the boundaries. This standard applies to the rated voltage of 72.5kV and above the gas-insulated metal-enclosed switchgear (GIS) and the power transformer between the single Phase and three-phase direct connection, the purpose is to establish the transformer connection of electrical and mechanical interchangeability and supply boundaries. One end of the direct connection is immersed in the transformer oil or insulating gas and the other end is immersed in the insulating gas of the switchgear. Transformers can be divided into single-phase closed single-phase transformer, with three transformer casing of the three single-phase closed or three-phase closed Arrangement of three-phase transformers. This standard meets GB/T 7674-2008 gas insulated metal enclosed switchgear, GB 1094 series power transformer and GB/T 4109 fully submerged casing requirements. In order to facilitate the use of this standard, the term "switchgear" means "gas insulated metal-enclosed switchgear". 1.2 Normative references The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 1094 (all parts) Power transformers [IEC 60076 (all parts)] Electrotechnical terms Insulators (IEC 60050-471..2007, IDT) GB/T 2900.8-2009 GB/T 4109-2008 Insulated bushings with AC voltages higher than 1000V (IEC 60137Ed.6.0, MOD) GB/T 7674-2008 Gas-insulated metal-enclosed switchgear with rated voltages up to and including 72.5 kV (IEC 62271-203..2003, MOD) GB/T 11022-2011 Common technical requirements for high voltage switchgear and control equipment (IEC 62271-1..2007, MOD) GB/T 13540-2009 Seismic requirements for high voltage switchgear and control equipment (IEC 62271-2..2003, MOD) IEC 61936-1..2007 Power units with alternating voltages above 1000V - Part 1. Generic rules (Powerinstalations exceeding1kVa.c.-Part 1. Commonrules2 normal and special conditions of useChapter 2 of GB/T 11022-2011 applies.3 terms and definitionsGB/T 2900.8-2009 and GB/T 11022-2011 and the following terms and definitions apply to this document. For the sake of convenience Use, the following repeated lists some terms and definitions. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 22382-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 22382-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 22382-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 22382-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 22382-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 22382-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |