GB/T 21451.3-2017 English PDFUS$339.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 21451.3-2017: Petroleum and liquid petroleum products -- Measurement of level and temperature in storage tanks by automatic methods -- Part 3: Measurement of level in pressurized tanks (non-refrigerated) Status: Valid
Basic dataStandard ID: GB/T 21451.3-2017 (GB/T21451.3-2017)Description (Translated English): Petroleum and liquid petroleum products -- Measurement of level and temperature in storage tanks by automatic methods -- Part 3: Measurement of level in pressurized tanks (non-refrigerated) Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: E30 Classification of International Standard: 75.180.30 Word Count Estimation: 17,155 Date of Issue: 2017-10-14 Date of Implementation: 2018-05-01 Regulation (derived from): National Standard Announcement 2017 No. 26 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 21451.3-2017: Petroleum and liquid petroleum products -- Measurement of level and temperature in storage tanks by automatic methods -- Part 3: Measurement of level in pressurized tanks (non-refrigerated)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Petroleum and liquid petroleum products-Measurement of level and temperature in storage tanks by automatic methods-Part 3. Measurement of level in pressurized tanks (non-refrigerated) ICS 75.180.30 E30 National Standards of People's Republic of China Petroleum and liquid petroleum products Automatic measurement of liquid level and temperature in tanks Part 3. Level measurement in pressurized tanks (not frozen) Petroleumand liquidpetroleumproducts-Measurementofleveland Part 3.Measurementoflevelinpressurizedtanks (non-refrigerated) (ISO 4266-3.2002, MOD) 2017-10-14 Published 2018-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 measures 2 5 Accuracy 3 6 ALG Installation 4 7 ALG Initial Site Initial Setup and Initial Test 5 8 ALG Post-Test 11 9 Data Communication and Reception 12 Reference 13 ForewordGB/T 21451 "Petroleum and liquid petroleum products tank automatic measurement of liquid level and temperature" is divided into six parts. --- Part 1. Atmospheric pressure tank level measurement; --- Part 2. Level measurement in tanker tanks; --- Part 3. Pressure tank (non-frozen) in the liquid level measurement; --- Part 4. Atmospheric pressure tank temperature measurement; --- Part 5. Tanker tank temperature measurement; --- Part 6. Temperature measurement in pressurized tanks (not frozen). This section GB/T 21451 Part 3. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the redrafted law Modify the use of ISO 4266-3.2002 "Petroleum and liquid petroleum products tank level and temperature automatic Measurement methods - Part 3. Level measurement in pressurized tanks (not frozen) ". This part of ISO 4266-3.2002 technical differences and the reasons are as follows. --- Added at the end of 6.4.1.2, "Connect the ALG to the isolation valve through the calibration chamber (or calibration fitting), which is a good solution to the ALG Setup, inspection, and float maintenance issues. "To solve the problem of effective ALG calibration; --- Change 6.4.3.2 to "In order to avoid the influence of the interference of the bottom of the tank, near the bottom of the tank should be provided to reduce the echo or deviate from the vertical Straight reflective plate (as shown in Figure 3), or similar device or mode. Reflector can be used as a reference plate, its installation It is best to measure the distance L accurately by manual method. "In order to clarify the role of the reflector and echo with the label of Figure 3; --- Replace the 6.4.3.3 "may not need to install and maintain the isolation valve" read "may be required for the installation of maintenance for each interval From the valve "to accurately express the actual use of isolation valve; --- Delete 6.4.4, incorporate the contents of 6.2.3, the original 6.4.5 into 6.4.4, the contents of 6.2.3 rewritten to avoid the level gauge Repeat the contents of the installation location --- In the last paragraph of 7.1.1 add a paragraph. "Through the above key distance can be set or check ALG reference point to the lowest tank bottom Point or tank surface zero level. "To illustrate the purpose of key distance measurements; --- Increase "7.1.2 installation level meter reference flange relative to the lowest point of the tank tank measurement", the original 7.1.2 and 7.1.3 order Becomes 7.1.3 and 7.1.4 to address the issue of pressure gauges and inspections where critical distances are often not directly measurable; --- Added after the content of 7.1.4 "Before setting up and checking the ALG, the data on the products to be installed in the tank Pre-verification, if necessary, should be the appropriate compensation or amendment. "In order to fully express the true intention of this article; --- 7.2.2.1b) in the "reference point" to "reference plate (or under the reference point)", and a) consistent; --- In 7.2.2.2, add "b) Adjust the reading of the ALG to be consistent with the predetermined upper reference point. The adjustment shall include Compensation values or correction factors affected by medium product density and ALG drain/float. ", The original b) into c), and modify "C) Return the level sensing element to the liquid level and lift it again to the upper reference point to record the ALG reading." Place the original c) Change to "d") and "repeat a) and b) three times" in its content "to" repeat c) three times "to conform to the actual meaning of the setting; --- In 7.3.1, "--- When ALG allows, measure the reference height." To "--- When the conditions permit, the measured reference high (See 7.1.2) to verify the correspondence between the mean ALG reading and the known measured distance. ", So that the sentence is more complete clear; --- Delete 8.4 "When meeting the tolerance requirement, ALG complies with the calibration requirements and is applicable to custody transfer" 8.5 understanding of mutual relations; --- The first sentence of 8.5.4 should read "When any tolerance specified in 8.5.2 and 8.5.3 is exceeded, even if the tolerance of 8.4 is met, The accuracy of the ALG measurement system should also be challenged and may still not apply to the transfer of trade. "Echo 8.4, 8.4 and 8.5 considered as a whole. This section made the following editorial changes. --- Increase in Note 3.4, indicating the actual significance of this part of the sounding reference; --- Increase in Note 3.7, indicating the actual meaning of measuring reference points in this section; --- In 3.11 steady fluid tube, increase the note, indicating the role of steady fluid tube on the level gauge; --- 5.3 Note 3a) "Accuracy" revised "uncertainty"; --- In Figure 3 illustrates the increase under "Note. The attenuation or deflecting plate shown in this figure perpendicular to the direction of the incoming radar wave can be directly used as a reference plate However, if the deflection plate reflects the radar wave to the stability pipe by changing its angle (greater than 90 °) with the direction of incidence of the radar wave In addition, you may want to configure the baseline separately. "; --- Reference ISO 4268.2000 with our standard GB/T 8927-2008 instead; --- Reference ISO 4512-2000 with our standard GB/T 13236-2011 instead. This part of the National Petroleum Products and Lubricants Standardization Technical Committee (SAC/TC280) and co-ordinated. This section is responsible for the drafting unit. China Petroleum and Chemical Corporation Petrochemical Research Institute. This section participates in the drafting unit. China Petrochemical Co., Ltd. Zhenhai Refining and Chemical Branch, Honeywell (China) Co., Ltd., Ai Somerset Process Control Co., Ltd. Beijing Ruisai Great Wall Aviation Measurement and Control Technology Co., Ltd. The main drafters of this section .Wei Jinxiang, Sun Yan, Chen Lei, Lu Dongfeng, Wang Hongzhi, Zhang Jin wide. Petroleum and liquid petroleum products Automatic measurement of liquid level and temperature in tanks Part 3. Level measurement in pressurized tanks (not frozen)1 ScopeGB/T 21451 provisions of this part of the oil and liquid petroleum products level measurement with automatic level gauge accuracy, installation, commissioning, Calibration and inspection, and gives guidance on the use of automatic level gauges (ALGs) in the custody transfer. This section applies to the use of immersion and non-immersion automatic level gauge on the pressure tank with storage, the vapor pressure does not exceed 4MPa stone Measurement of liquid level of oil and liquid petroleum products. This section does not apply to the cave and cryogenic storage tanks used in the ALG level measurement.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. ISO .1998 (all parts) Petroleumindustry-Terminology3 Terms and definitionsISO .1998 defines the following terms and definitions apply to this document. 3.1 Anchor weight anchorweight Hanging on the guide line of the automatic level gauge test element, the guide line tensioned and straightened ballast. 3.2 Automatic level gauge automaticlevelgauge (ALG); automatictankgauge (ATG) Continuous measurement of tank level (height or height) of the instrument. 3.3 Real high dip; innage The vertical distance between the reference point and the liquid level. 3.4 Sounding reference plate dippingdatumplate Sounding reference point dippingdatumpoint Depth dip plate Just below the measurement reference point, a horizontal metal plate is provided for manually measuring the depth of the liquid to provide a fixed contact surface. Note. This section of the sounding reference plate is mainly used for automatic level gauge calibration and inspection, and vertical pressure tank may have different purposes, and generally not as a tank Yung table table zero. 3.5 Dip dipstick A graduated steel tape ruler, taut, for measuring the depth of oil or water in a tank, either directly or through space-time measurement by sounding. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 21451.3-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 21451.3-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 21451.3-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 21451.3-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |