GB/T 2099.9-2017 English PDFUS$599.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 2099.9-2017: Plugs and socket-outlets for household and similar purposes -- Part 2-9: Particular requirements for socket-outlets for information Status: Valid
Basic dataStandard ID: GB/T 2099.9-2017 (GB/T2099.9-2017)Description (Translated English): Plugs and socket-outlets for household and similar purposes -- Part 2-9: Particular requirements for socket-outlets for information Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K30 Classification of International Standard: 29.120.30 Word Count Estimation: 30,354 Date of Issue: 2017-09-29 Date of Implementation: 2017-11-01 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 2099.9-2017: Plugs and socket-outlets for household and similar purposes -- Part 2-9: Particular requirements for socket-outlets for information---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Plugs and socket-outlets for household and similar purposes-Part 2-9. Particular requirements for socket-outlets for information ICS 29.120.30 K30 National Standards of People's Republic of China Household and similar plugs and sockets Part 2-9. Particular requirements for information outlets Part 2-9.Particularrequirementsforsocket-outletsforinformation 2017-09-29 Posted 2018-04-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 General requirements 4 5 General description of the test 4 6 rating 4 7 Categories 4 8 logo 4 9 size check 5 10 terminal and terminal 5 11 fixed socket structure 7 Structure of 12 plugs and mobile sockets 13 anti-aging, provided by the protective shell and moisture 8 Insulation resistance and electrical strength 8 15 normal operation 9 16 force required to pull out the plug 9 17 flexible cable and its connection 9 Mechanical strength 11 19 heat 12 20 screws, current-carrying parts and their connections 12 21 Creepage distance, clearance and distance through sealant 12 22 Insulation resistance to abnormal heat, flame and tracking resistance 12 23 rust performance 12 EMC requirements 12 Transmission Features 13 Environmental Adaptability 20 Reliability 27 Appendix A (Normative) Test sample list required 22 References 23 Figure 1 connector derating curve 20 Figure 2 Sweep instrument to measure the device connection 20 Figure 3 equipment used to measure the reflection loss of the scanner connection 21 Figure 4 Closed-loop Probes for Shielding Fading Measurement 21 Table 1 Information Socket Type Corresponding to connect copper wire specifications 6 Table 2 threaded terminal tensile test value 6 Table 3 wire structure 6 Table 4 Surface Mount Outlets with external cable size limit 7 Table 5 Flexible Cable Fittings External Dimensions of Flexible Cables 10 Table 6 soft rope fixed components torque test value 10 Table 7 Clearances and creepage distances 12 Table 8 Network Interface Information Socket minimum return loss 13 Table 9 Network Interface Information Socket Maximum Insertion Loss 14 TABLE 10 Insertion Loss and Branch Loss Requirements for Terminal and Serial Cable Systems 14 Table 11 Network Interface Information Minimum Socket Near-End Crosstalk 15 Table 12 Network Interface Information Socket Minimal End Cross-talk Attenuation Power and 15 Table 13 Network Interface Information Socket Minimum Remote Crosstalk attenuation 16 Table 14 Network Interface Information Socket Minimal Remote Crosstalk Attenuation Power and 16 Table 15 Network Interface Information Socket Minimum Transverse Loss 17 Table 16 Maximum Class Transfer Impedance of the Shield Type Network Interface Information Socket 18 Table 17 Terminal cable TV system output flatness with the band 18 Table 18 - Termination and serial television interface information outlet outlet reflection loss requirements 19 Table 19 Terrestrial TV interface information Socket outlet attenuation requirements of 19 Table A.1 Test sample list required 22 ForewordGB/T 2099 "Household and similar plugs and sockets" is divided into the following sections. --- Part 1. General requirements --- Part 2. Special requirements ● Fuse plugs with special requirements ● appliance socket special requirements ● Converter special requirements ● Fixed non-interlocking switch socket with special requirements ● Fixed with interlock switch socket special requirements ● Extension cord socket special requirements ● Special Requirements for Safety Extra Low Voltage (SELV) Plug and Socket ● Information socket special requirements This section GB/T 2099 Part 2-9. This section drafted in accordance with GB/T 1.1-2009 given rules. This part is proposed by China Electrical Equipment Industry Association. This part of the National Electrical Accessories Standardization Technical Committee (SAC/TC67) centralized. This part of the drafting unit. China Electric Apparatus Research Institute Co., Ltd., Hangzhou Hongyan Electric Co., Ltd., Ningbo Bulls Electric Co., Ltd., Zhejiang Chint Building Electric Co., Ltd., Schneider Electric (China) Co., Ltd. Shenzhen Branch, Matsushita Information Instruments (Shanghai) Co., Ltd., Huizhou Hongfeng Industrial Co., Ltd., Wei Kai Detection Technology Co., Ltd., Beijing Branch to Bo Electronic Technology Co., Ltd., Siemens (in Ltd.) Shanghai Branch, Beijing ABB Low Voltage Electric Co., Ltd., Flying Eagle Electric Group Co., Ltd., Yuehua Holding Group Co., Ltd. Division, Zhejiang East Cape Electronic Technology Co., Ltd., Nanping, Fujian Nanfu Battery Co., Ltd., Guangzhou Panyu Tianhong Industrial Development Co., Ltd., Neos Electrical (Jiaxing) Co., Ltd., Shantou City Jiancheng Hardware Plastic Co., Ltd., Shenzhen Jiesheng Technology Co., Ltd., Shenzhen times pass detection of shares Co., Ltd., Ningbo Branch IC Design Center Co., Ltd.. The main drafters of this section. Cai Jun, Wang Fengqin, Ruan Liping, Lin Zhongjie, Gong Zhilei, Yan Jingjing, Ho even, Li Qin, Shao Jing Jiang, Chappen Show, Miao Cancan, Zheng Wei, Wang Sheng, Jiang Qiang, Lin Wende, Li Tatin, Jiang Jiulong, Xin Ruijian, Zhang Weijia, Zhao Xingmao, Huang Chao, Shen members, Ye Haifeng, Huang Shun pro, Chen Kejie, Luo Shiming, Zhang Lirong. Household and similar plugs and sockets Part 2-9. Particular requirements for information outlets1 ScopeThis section GB/T 2099 specifies the signs for household and similar use of information outlets, anti-shock protection, structure, electrical performance, machine Mechanical performance and other technical requirements. This section applies to indoor or outdoor use, domestic and similar purposes, for connecting the Internet and the transmission of information fixed socket or Mobile sockets. The information outlet is suitable for use in the following ambient temperatures, typically not exceeding 40 ° C but not exceeding 35 ° C over a period of 24 hours, The lower limit of ambient air temperature is -5 ° C. Note. At present, this section of the information socket for telephone interface information outlet, network interface information outlet and TV interface information outlet, other information outlet (Eg, audio interface information outlet) is under consideration.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. Plugs and socket outlets for household and similar use - Part 1. General requirements GB 4943.1 Information technology equipment safety Part 1. General requirements GB/T 5095.2-1997 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 2. General inspection, electrical Continuity and contact resistance test, insulation test and voltage stress test GB/T 5095.3-1997 Electromechanical components for electronic equipment Basic test procedures and measurement methods Part 3 Current carrying capacity test GB/T 5095.5-1997 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 5 Impact test (from From pieces), static load test (fixed components), life test and overload test GB/T 5095.7-1997 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 7. Mechanical operation test Inspection and sealing test GB/T 5465.2 Graphical symbols for electrical equipment - Part 2. Graphical symbols GB/T 11016 (all parts) Plastic insulated and rubber insulated telephone cords (all parts) GB/T 11313.2-2007 RF connectors Part 2 .9.52 RF coaxial connector sub-specification GB/T 11318.1-1996 cable television and sound signal distribution system equipment and components - Part 1. General specification GB/T 11318.12-1996 cable television and sound signal distribution system equipment and components - Part 12. System output through Use specifications GB/T 15157.7 Printed board connectors with frequencies below 3 MHz - Part 7. Qualitative evaluation with universal mating characteristics 8-bit fixed and free connector detail specification GB/T 16935.1 Insulation coordination of equipment in low-voltage systems - Part 1. Principles, requirements and tests GB/T 17194-1997 Electrical conduit Electrical installation of the catheter outer diameter and catheter and accessories thread GB/T 18015.3 digital communications for twisted pair or twisted multi-core symmetrical cables Part 3. Wiring cabling work area specification GB/T 18290.3-2000 Solderless connections - Part 3. Contactable solderable insulation displacement connections - General requirements Test methods and Use guidelines ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 2099.9-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 2099.9-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 2099.9-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 2099.9-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |