Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 20147.3-2023 English PDF

US$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 20147.3-2023: Colorimetry - Part 3: CIE tristimulus values
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 20147.3-2023189 Add to Cart 3 days Colorimetry - Part 3: CIE tristimulus values Valid

Similar standards

GB/T 39021   GB/T 35626   GB/T 3978   GB/Z 45268   GB/T 20150   GB/T 20147.4   

Basic data

Standard ID: GB/T 20147.3-2023 (GB/T20147.3-2023)
Description (Translated English): Colorimetry - Part 3: CIE tristimulus values
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K70
Classification of International Standard: 17.180.20
Word Count Estimation: 10,110
Date of Issue: 2023-08-06
Date of Implementation: 2024-03-01
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 20147.3-2023: Colorimetry - Part 3: CIE tristimulus values

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 17.180.20 CCSK70 National Standards of People's Republic of China Colorimetry Part 3.CIE Tristimulus Values (ISO /CIE11664-3.2019,MOD) Published on 2023-08-06 2024-03-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee

Table of contents

PrefaceⅠ Introduction II 1 Scope 1 2 Normative reference documents 1 3 Terms and Definitions 1 4 symbols 1 5 Standard Method 2 6 Simplified method 4 7 Supplementary processing of input data 5 8 chromaticity coordinates 6 9 Numerical Program 6 10 Results Report 6 Reference 7

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document is Part 3 of GB/T 20147 "Colorimetry". GB/T 20147 has published the following parts. ---Part 3.CIE tristimulus value; ---Part 4.CIE1976L*a*b* color space. This document is modified to adopt ISO /CIE11664-3.2019 "Colorimetry Part 3.CIE Tristimulus Values". The technical differences between this document and ISO /CIE11664-3.2019 and their reasons are as follows. ---Added the description of the scope of application (see Chapter 1); ---Replaced CIES017 with normatively quoted GB/T 2900.65 to adapt to my country's technical conditions and increase operability (see Chapter 3); ---Note 1 in 6.2 is changed to the main text to comply with the writing rules of our country's standards (see 6.2); ---Note 1 in 7.2 is changed to the main text to comply with the writing rules of our country's standards (see 7.2). The following editorial changes have been made to this document. ---Change the title of Chapter 4 "Symbols and Abbreviations" to "Symbols". Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document is proposed by China Light Industry Federation. This document is under the jurisdiction of the National Lighting Appliances Standardization Technical Committee (SAC/TC224). This document was drafted by. Zhejiang University, Shenzhen Baoan District New Display Industry Technology Promotion Center, Guangzhou Mingdao Culture Technology Group Co., Ltd., Foshan Electrical and Lighting Co., Ltd., Zhongshan Songwei Lighting and Electrical Co., Ltd., Binzhou University, Fudan University, Shenzhen Municipal Yangguang Electronics Co., Ltd., Beijing Electric Light Source Research Institute Co., Ltd., Fujian Institute of Engineering, Wuhan University, China Metrology Research Institute, China Illuminating Society, Communications and Signal Research Institute of China Academy of Railway Sciences Group Co., Ltd., and Wuxi Institute. The main drafters of this document. Ye Wei, Zeng Xiaolan, Chen Hao, Yu Shaotao, Xie Wei, Xu Haisong, Zhang Fuzheng, Lin Yandan, Qin Shengyan, Zhang Bo, Du Feng, Liu Qiang, Zhao Weiqiang, Bi Xiaoman, Li Toyota, Huang Sungang.

Introduction

Color stimuli with different spectral distributions may appear the same. An important function of colorimetry is to use a given set of colors The color matching function determines which stimuli look similar to a given observer. This is achieved by calculating tristimulus values for each stimulus. Equality of the three stimulus values indicates equal color appearance under the same illumination and observation conditions. This document is based on CIE’s long-term analysis of tristimulus values. Definitely recommended. According to the characteristics of different workplaces, GB/T 20147 is planned to be divided into the following six parts. ---Part 1.CIE standard colorimetric observer. The purpose is to specify two sets of color matching functions in colorimetry. ---Part 2.CIE standard lighting body. The purpose is to specify two standard illuminants in colorimetry. ---Part 3.CIE tristimulus value. The purpose is to specify a method for calculating the tristimulus value of a color stimulus of known spectral distribution. ---Part 4.CIE1976L*a*b* color space. The purpose is to specify the calculation of CIE1976L*a*b* color space coordinates method and two methods for calculating Euclidean color difference in this space. ---Part 5.CIE1976L*u*v* color space and u', v' uniform chromaticity scale diagram. The purpose is to specify the calculation CIE1976 L*u*v* color space coordinate method, two methods for calculating Euclidean color difference in this space, and calculating u', v' uniformity Method for chromaticity scale diagram coordinates. ---Part 6.CIEDE2000 color difference formula. The purpose is to specify the method for calculating color difference based on the CIEDE2000 color difference formula. Colorimetry Part 3.CIE Tristimulus Values

1 Scope

This document specifies methods for calculating tristimulus values for color stimuli of known spectral distribution that can be produced by self-illuminating light sources or Produced by reflective or transmissive objects. This document specifies the color stimulus function at least within the wavelength range of 380nm~780nm with a measurement interval not exceeding 5nm. Tabulate. For wavelength measurement ranges less than 380nm~780nm, it is recommended to use the extrapolation method. This document gives a standard method for summation at intervals of 1 nm in the wavelength range from 360nm to 830nm. to bigger Wavelength spacing (up to 5nm) and shorter wavelength ranges (as short as 380nm~780nm) define alternative simplified methods. only at Use alternative methods only where appropriate and after the user has reviewed the impact on the final result. This document applies to colorimetric calculations, colorimetric measurement instrument design, manufacturing and colorimetric measurement related application fields. This document can be used in conjunction with the CIE1931 standard colorimeter observer or the CIE1964 standard colorimeter observer.

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document. GB/T 2900.65 Electrical terminology lighting [GB/T 2900.65-2004, IEC 60050(845).1987, MOD] ISO /CIE11664-1 Colorimetry Part 1.CIE standard colorimetry observer (Colorimetry-Part 1.CIEstandard

3 Terms and definitions

The terms and definitions defined in GB/T 2900.65 apply to this document.

4 symbols

The following symbols apply to this document. k,k10 normalization constant Km Maximum spectral photovisual efficacy of radiation in CIE standard physical photometry system Maximum spectral optical performance of radiation when Km,10 V10(λ) function is used in photometry R(λ) spectral reflection factor S(λ) Relative spectral distribution of illuminant V(λ) Spectral optical efficiency function in CIE standard physical photometry system V10(λ) y10(λ) function is the spectral optical efficiency function when used in photometry Wx(λ),Wy(λ),Wz(λ) precomputed weights for tristimulus value integration using CIE1931 standard colorimetric observers function Wx,10(λ),Wy,10(λ),Wz,10(λ) Precomputed weights for tristimulus value integration by CIE1964 standard colorimetric observer
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 20147.3-2023_English be delivered?

Answer: Upon your order, we will start to translate GB/T 20147.3-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 20147.3-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 20147.3-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.