Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 20013.4-2010 English PDF

US$114.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 20013.4-2010: Nuclear medicine instrumentation -- Routine tests -- Part 4: Radionuclide calibrator
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 20013.4-2010114 Add to Cart 3 days Nuclear medicine instrumentation -- Routine tests -- Part 4: Radionuclide calibrator Valid

Similar standards

GB/T 13797   GB/T 20013.3   GB 9706.5   GB/T 19042.6   GB/T 19042.5   

Basic data

Standard ID: GB/T 20013.4-2010 (GB/T20013.4-2010)
Description (Translated English): Nuclear medicine instrumentation -- Routine tests -- Part 4: Radionuclide calibrator
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: C43
Classification of International Standard: 11.040.50
Word Count Estimation: 6,636
Date of Issue: 2010-09-02
Date of Implementation: 2011-02-01
Quoted Standard: GB/T 17857-1999; GB/T 20013.1-2005; IEC 61145-1992; IEC 61303-1994
Adopted Standard: IEC/TR 61948-4-2006, IDT
Regulation (derived from): National Standard Approval Announcement 2010 No.4 (Total No.159)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard applies to radionuclide calibrator routine tests. The device uses the well-type blending chamber (directly connected to a suitable electronic circuit (1EC 61145)) and direct reading in units of activity. IEC 61303 and IEC 61145 describes the determination of the required performance parameters and rules approach. These methods are mainly designed for the acceptance test.

GB/T 20013.4-2010: Nuclear medicine instrumentation -- Routine tests -- Part 4: Radionuclide calibrator


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Nuclear medicine instrumentation.Routine tests.Part 4. Radionuclide calibrator ICS 11.040.50 C43 National Standards of People's Republic of China Routine practice of nuclear medicine instruments Part 4. radionuclide calibrator Part 4. Radionuclidecalibrator (IEC /T R61948-4..2006, IDT) 2010-09-02 release 2011-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released

Foreword

GB/T .20013 "nuclear medicine instrument routine test" is divided into four parts. - Part 1. Radiation counting system; Part 2. Scintillating cameras and single photon emission computed tomography devices; - Part 3. positron emission tomography; Part 4. Radionuclide Calibrator. This part is part 4 of GB/T .20013. This part is equivalent to the use of IEC /T R61948-4..2006 "Nuclear medicine instrument routine test Part 4. Radionuclide Calibrator" (English version). For ease of use, this section makes the following editorial changes. - the preamble and introduction to the deletion of international standards; - the origin of each term is removed in Chapter 3; - In Chapter 2, "normative reference documents", according to the requirements of GB/T 1.1 increased the guide; - For other international standards cited in the standard, if this has been converted to our standard, this part replaces the corresponding international with the national standard number Standard; --- the abolition of the international standard "term index"; --- with decimal point "." Instead of decimal point ",". This part is made by the State Food and Drug Administration. This part is headed by the National Standardization Technical Committee for Medical Electrical Appliances (SAC/TC10). This part of the drafting unit. Beijing Medical Device Testing Institute. The main drafters of this part. Chen Jing, Wang Peichen, Song Lianyou, Zhang Xin. Routine practice of nuclear medicine instruments Part 4. radionuclide calibrator

1 scope and purpose

This part of GB/T .20013 includes routine testing of radionuclide calibrators used in nuclear medicine. The device uses well type ionization (Directly connected to an appropriate electronic circuit (IEC 61145)) and read directly in units of activity. IEC 61303 and IEC 61145 describes the requirements and specifications for determining performance parameters. These methods are primarily designed for acceptance testing.

2 normative reference documents

The terms of this document are the terms of this part through the reference in this part of ISO /Any reference to the date of the text , All subsequent amendments (excluding corrigenda) or revisions do not apply to this part, however, encouragement under this section The parties to the agreement study whether the latest version of these documents can be used. For undated references, the latest edition of this document applies section. GB/T 17857-1999 Medical radiology terminology (Radiation therapy, nuclear medicine and radiation dosimetry equipment) (eqvIEC 60788. 1984) GB/T .20013.1-2005 Routine test for nuclear medicine instruments - Part 1. Radiation counting system (IEC 61948-1..2001, IDT) IEC 61145..1992 Calibration and use of ionization chamber systems for the measurement of radionuclides IEC 61303..1994 Medical electrical equipment - Radioactive nuclide calibrators - Specific methods for describing performance

3 terms and definitions

GB/T 17857-1999, IEC 61303..1994 and IEC 61145..1992 and the following terms and definitions apply to This part of GB/T .20013. 3.1 Acceptance test acceptancetest As required by the user or user representative, by determining the appropriate performance parameters to determine the instrument to meet the seller's statement Technical parameters of the test. Note. Acceptance tests should be carried out at the appropriate time after installation and after completion of major services. During the acceptance test or the acceptance test has just been completed, Test data are compared with subsequent routine test data. 3.2 Routine test routinetest The test of the device or its parts at a specified time interval is repeated to determine and record the document relative to the reference data The change of the initial state. Note. Routine tests can be done by the user using simple methods and equipment. 3.3 Ionization chamber test source ionizationchambertestsource A radioactive source used to determine the long - term stability of an ionization chamber. The half-life of the source should be greater than 5a, except for the major radionuclides, other radioactive The effect of nuclide content should be as small as possible, that is, within 5a, the indication given by the test device is the same as the primary radionuclide half-life correction Between the deviation of not more than 0.5%. Note. The ionization chamber test source is used to test the function of the radionuclide calibrator under specified conditions.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 20013.4-2010_English be delivered?

Answer: Upon your order, we will start to translate GB/T 20013.4-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 20013.4-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 20013.4-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.