Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 19972-2018 English PDF

US$1024.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 19972-2018: Sterilization of health care products -- Biological indicators -- Guidance for the selection, use and interpretation of results
Status: Valid

GB/T 19972: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 19972-20181024 Add to Cart 5 days Sterilization of health care products -- Biological indicators -- Guidance for the selection, use and interpretation of results Valid
GB/T 19972-2005RFQ ASK 4 days Sterilization of health care products -- Biological indicators -- Guidance for the selection, use and interpretation of results Obsolete

Similar standards

GB/T 19973.2   GB/T 19633.2   GB/T 19973.1   

Basic data

Standard ID: GB/T 19972-2018 (GB/T19972-2018)
Description (Translated English): Sterilization of health care products -- Biological indicators -- Guidance for the selection, use and interpretation of results
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: C47
Classification of International Standard: 11.080.01
Word Count Estimation: 54,545
Date of Issue: 2018-03-15
Date of Implementation: 2018-10-01
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 19972-2018: Sterilization of health care products -- Biological indicators -- Guidance for the selection, use and interpretation of results


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Sterilization of health care products--Biological indicators--Guidance for the selection, use and interpretation of results ICS 11.080.01 C47 National Standards of People's Republic of China Replace GB/T 19972-2005 Health care product sterilization biological indicator Choice, use, and results judgment guide (ISO 14161.2009, IDT) Published on.2018-03-15 2018-10-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration issued

Content

Foreword I Introduction II 1 Scope 1 2 Normative references 1 3 Terms and Definitions 2 4 General 5 5 biological indicator characteristics 6 6 supplier selection 8 7 Biological indicators in process development 9 8 Sterilization confirmed biological indicators 11 9 Biological indicators in routine monitoring 12 10 result 13 11 Application of biological indicator standards 14 12 Culture conditions 19 13 Requirements for third parties 21 14 Staff Training 21 15 Storage and management 22 16 Biological Indicator Processing 22 Appendix A (informative) Microbial inactivation mechanics and counting methods 23 Appendix B (informative) Process Challenge Device 27 Appendix C (informative) Partial negative method for determining D value 28 Appendix D (informative) Example of a transcript of a biological indicator prepared by the user 40 Appendix E (informative) Calculation of z-values 44 Appendix F (informative) Survival curve method measures D value 46 Appendix G (informative) Survival-killing response characteristics 49 Reference 50

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 19972-2005 "Guidelines for the Selection, Use and Result Judgment of Sterilized Biological Indicators for Healthcare Products". The main technical differences between this standard and GB/T 19972-2005 are as follows. --- Added "duration", "installation identification", "running identification", "performance identification", "process variable", "reference microorganism", "spore log reduction" Terms and definitions of “less value” “sterility assurance level” and “survival-kill interval” (see 3.6, 3.8, 3.11, 3.12, 3.16, 3.17, 3.19, 3.21 and 3.26); --- Added the informative appendix "calculation of z values" (see Appendix E); --- Added the informative appendix "survival curve method to measure D value" (see Appendix F); --- Added the informative appendix "Survival-killing response characteristics (see Appendix G)". This standard uses the translation method equivalent to the ISO 14161.2009 "healthcare product sterilization biological indicator selection, use and knot Judgment Guide. The documents of our country that have a consistent correspondence with the international documents referenced in this standard are as follows. ---GB 18278.1-2015 Health care products Sterilization and moist heat Part 1. Development, validation and validation of medical device sterilization processes General control requirements (ISO 17665-1.2006, IDT) ---GB 18279.1-2015 Health care products Sterilization of ethylene oxide Part 1. Development of medical device sterilization process, indeed Recognition and routine control requirements (ISO 11135-1.2007, IDT) --- GB 18281.1-2015 Sterilization of biological indicators for health care products - Part 1. General (ISO 11138-1.2006, IDT) --- GB 18281.2-2015 Sterilization of biological indicators for health care products - Part 2. Biological indications for the sterilization of ethylene oxide (ISO 11138-2.2006, IDT) --- GB 18281.3-2015 Sterilization of biological indicators for health care products - Part 3. Biological indicators for moist heat sterilization (ISO 11138-3.2006, IDT) --- GB 18281.4-2015 Sterilization of biological indicators for health care products - Part 4. Biological indicators for dry heat sterilization (ISO 11138-4.2006, IDT) --- GB 18281.5-2015 Sterilization of biological indicators for health care products - Part 5. Indicator (ISO 11138-5.2006, IDT) --- GB/T 19973.1-2015 Microwaveological methods for the sterilization of medical devices - Part 1 Ding (ISO 11737-1.2006, IDT) ---GB/T 19974-2005 Characteristics of Sterilization Factor of Healthcare Products and Setting and Confirmation of Sterilization Process of Medical Devices General requirements for general control and control (ISO 14937.2000, IDT) Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This standard was proposed by the State Food and Drug Administration. This standard is under the jurisdiction of the National Disinfection Technology and Equipment Standardization Technical Committee (SAC/TC200). This standard was drafted. Guangdong Medical Device Quality Supervision and Inspection Institute, Beijing Jikayi Technology Co., Ltd., 3M China Co., Ltd. The main drafters of this standard. Wu Weirong, Qian Yingjie, Zhang Yang, Huang Jingxiong. The previous versions of the standards replaced by this standard are. ---GB/T 19972-2005.

Introduction

This standard provides guidance on the selection, use, and determination of biological indicators when applied to the development, validation, and monitoring of sterilization processes. The procedures described in this standard are of a general nature and are not themselves a comprehensive development, validation and monitoring process for the sterilization of healthcare products. sequence. The purpose of this standard is not to force the use of biological indicators in a process, but to correctly select them if biological indicators are used. Choose and use guidelines to avoid misleading results. In this standard, users can obtain biological indicator selection guides for specific sterilization processes and key parameters, and use the health correctly. A guide to objects. The user should select a biological indicator that is appropriate for the particular sterilization process they employ. Biological indications due to large differences in sterilization processes It is difficult for the manufacturer to anticipate all possible uses of the product, so the manufacturer can only identify its biological indicator for a particular use. For mining The specific sterilization process used should be properly selected, used, recycled, and judged by the user. Conditions for storage and transport of biological indicators prior to use, use of biological indicators or sterilizer process parameters may be indicative of biological indicators Adverse effects, in addition to the culture techniques used after exposure to the process, including culture temperature, media type, manufacturer and specific batches may also It is the measured resistance associated with recovery and growth. Therefore, it should be stored and used in accordance with the recommendations of the biomarker manufacturer. After sterilization, Biological indicators should be aseptically transferred (if applicable) and cultured as specified by the biomarker manufacturer. It should be noted that the biological indicator is not intended to indicate that the sterilized item is indeed sterile. But to test a known sterilization process and The effectiveness of the sterilization equipment used, which is based on the principle of assessing microbial lethality at a sterility assurance level. This Class studies should be conducted by trained and appropriate personnel. Health care product sterilization biological indicator Choice, use, and results judgment guide

1 Scope

This standard provides for the selection, use, and judgment of biological indicators when applied to the development, validation, and routine monitoring of sterilization processes. guide. This standard applies to biological indicators of existing national standards. Note 1. See ISO 11138 for an example. Note 2. The general information provided in this standard also applies to processes and biological indicators not mentioned in the current national standards. Such as new and developing sterilization process. This standard does not consider processes that physically remove microorganisms only, such as filtration. This standard does not apply to the use of various combination processes, such as washing and sterilizing or pipe flushing and steaming. This standard does not apply to liquid sterilization processes.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 24628-2009 Sterilization biological and chemical indicator test equipment for healthcare products (ISO 18472.2006, IDT) ISO 11135-1 Sterilization of ethylene oxide for health care products - Part 1. Development, validation and routine Control requirements (Sterilizationofhealthcareproducts-Ethyleneoxide-Part 1. Requirements fordevelop- Ment,validationandroutinecontrolofasterilizationprocessformedicaldevices) ISO 11138-1.2006 Medicinal products - Sterilization of biological indicators - Part 1 products-Biologicalindicators-Part 1.Generalrequirements) ISO 11138-2 Sterilization of biological indicators for health care products - Part 2. Biological indicators for the sterilization of ethylene oxide (Sterili- zationofhealthcareproducts-Biologicalindicators-Part 2.Biologicalindicatorsforethyleneoxide Sterilizationprocesses) ISO 11138-3 Sterilization of biological indicators for health care products - Part 3 ofhealthcareproducts-Biologicalindicators-Part 3.Biologicalindicatorsformoistheatsterilization Processes) Biomedical products - Sterilization of biological indicators - Part 4. Sterilization for dry heat sterilization ofhealthcareproducts-Biologicalindicators-Part 4.Biologicalindicatorsfordryheatsterilization Processes) Biomedical products - Sterilization of biological indicators - Part 5. Biological indicators for steril (Sterilizationofhealthcareproducts-Biologicalindicators-Part 5. Biologicalindicatorsforlow-tem- Peraturesteamandformaldehydesterilizationprocesses) ISO 11737-1 Methods of sterilizing microbiology of medical devices - Part 1 (Sterilizationofmedicaldevices-Microbiologicalmethods-Part 1.Determinationofapopulationof Microorganisms products) ISO 14937 Characteristics of Sterilization Factors for Healthcare Products and Development, Validation and Routine Control of Medical Device Sterilization Processes General requirements (Sterilizationofhealthcareproducts-Generalrequirementsfor characterizationofasterili- Zingagentandthedevelopment,validationandroutinecontrolofasterilizationprocessformedicalde- Vices) ISO 17665-1 Sterilization of moisturizing products for health care products - Part 1. Development, validation and routine control Requirements (Sterilization of health care products - Moistheat-Part 1. Requirements for the development, Validationandroutinecontrolofasterilizationprocessformedicaldevices)

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Accreditation accreditation Formally indicate that the conformity assessment body has a third-party certificate for the ability to perform specific conformity assessment work. Note 1. See ISO /IEC 17011 [3]. Note 2. Accreditation itself does not confirm that the laboratory has the qualification to approve a product, but when the approval and certification authority decides whether to adopt a specific laboratory When it comes to data about its own activities, recognition is related to this. 3.2 Aseptic technique aseptictechnique To rule out the conditions and methods used for microbial contamination. 3.3 Bioburden The total number of viable microorganisms on the surface and/or inside of a product and/or sterile barrier system. [ISO /T S11139, Definition 2.2] 3.4 Biological indicator biologicalindicator; BI A test system containing viable microorganisms with defined resistance to a defined sterilization process. [ISO /T S11139, Definition 2.3] 3.5 D value Dvalue D10 value D10value The time or dose required to inactivate 90% of the total number of test microorganisms under specified conditions. [ISO /T S11139, definition 2.11] 3.6 Duration holdingtime During a sterilization phase, the sterilization variables in the sterilizer and all locations within the load are maintained within the specified limits. 3.7 Bacteria carrier inoculatedcarrier A vector that has been stained with the indicated number of test microorganisms. Note 1. See ISO 11138-1. Note 2. The test microorganism is a microorganism used for the production of the carrier for the infection. 3.8 Installation identification instalationqualification; IQ The process of obtaining evidence and documenting evidence that the equipment has been provided and installed as required by the technical specifications. [ISO /T S11139, definition 2.22] 3.9 Inoculation A specified number of specific microbial entities are added to the interior or surface of the article. 3.10 Log reduction value logreduction; LR The decrease in the number of viable microorganisms is expressed in units of lg. 3.11 Operational authentication operationalqualification; OQ Obtain evidence and document the process of proving that the installed equipment is in the intended range when the equipment is used in accordance with the equipment operating procedures Running inside. [ISO /T S11139, definition 2.27] 3.12 Performance qualification performancequalification; PQ Obtain evidence and document the process of proving that equipment that has been installed and operated according to the operating procedures will continue to be stable according to predetermined criteria Produce products that meet the requirements of product specifications. [ISO /T S11139, definition 2.30] 3.13 Process challenge device processchalengedevice; PCD A device that constitutes a specific resistance to the sterilization process and is used to evaluate the effectiveness of the sterilization process. [ISO /T S11139, definition 2.33] 3.14 Process challenge site processchalengelocation; PCL It is possible to simulate a sterilization factor in a "most unfavorable state" position in a batch of items to be sterilized. 3.15 Process parameter processparameter The specified value of the process variable. Note. The specified values for the sterilization process include process parameters and their tolerances. [ISO /T S11139, definition 2.34] 3.16 Process variable processvariable Conditions within the scope of the sterilization process can change the effectiveness of the sterilization. Examples. time, temperature, pressure, concentration, humidity, wavelength. [ISO /T S11139, definition 2.35] 3.17 Reference microorganism referencemicroorganism A microbial strain obtained by a recognized strain collection institution. [ISO /T S11139, definition 2.39] 3.18 Resistance meter Test equipment designed to produce a combination of physical and/or chemical variables during the sterilization process. Note 1. According to ISO 11138-1, definition 3.15 and GB/T 24628-2009, definition 3.11. Note 2. The biometric indicator resistance tester (BIER) is also referred to. 3.19 Spore log reduction value spore-log-reduction; SLR The logarithm of the initial number of spores, N0, minus the logarithm of the final number of spores, NF. 3.20 Sterile sterile No living microorganisms. [ISO /T S11139, definition 2.43] 3.21 Sterility assurance level sterilityassurancelevel; SAL The probability of a single living microorganism present on the product after sterilization. Note. The term “SAL” is expressed in terms of magnitude and is usually 10-6 or 10-3. When applying this magnitude to the sterility assurance level, the 10-6 SAL has a lower The value thus provides a greater level of sterility assurance than the 10-3 SAL. [ISO /T S11139, definition 2.46] 3.22 Sterilization sterilization A confirmed process for making the product free of viable microorganisms. Note. During sterilization, the nature of microbial inactivation is exponential; thus the survival of microorganisms on a single product can be expressed in terms of probability. although This probability can be reduced to very low, but it is impossible to drop to zero, see "Aseptic Assurance Level". [ISO /T S11139, definition 2.47] 3.23 Sterilization cycle development sterilizationcycledevelopment The process of determining the appropriate process parameters such that a known product or class of products achieves the desired ratings and label claims. 3.24 Sterilization cycle confirmation sterilizationcyclevalidation Used to obtain, document, and describe results documenting procedures and to establish a sustainable production of products that meet expected technical specifications. process. 3.25 Supplier supplier The organization or individual that provided the product. Examples. Manufacturers, wholesalers, retailers of products, or providers of vendors, services, or information. Note 1. The supplier can be internal or external to the organization. Note 2. The supplier sometimes becomes a “contractor” in the case of a contract. [ISO 9000, Definition 3.3.6] 3.26 Survival-killing interval survival-kilwindow When sterilized under the specified conditions, the biological indicator transitions from all living microorganisms (survival time) to all killed microorganisms (killing) The degree of exposure of the time). [ISO 11138-1, definition 3.18] 3.27 Third party thirdparty An individual or institution that is recognized as independent of the parties involved in the issues involved. Note 1. See ISO /IEC Guide 2 [1]. Note 2. The parties concerned are usually the supplier (first party) and the demander (second party). 3.28 User user Individuals and institutions that use biological indicators for their intended use. Note 1. See ISO 9000 [4]. Note 2. The customer is the customer of the product provided by the supplier. In the case of the contract, the user may be referred to as the “buyer”. The user can be a customer, a consignee or a buyer. user It can be internal or external to the organization and represents the “second party”. 3.29 z value zvalue The value of the exposure temperature required to vary the value of D by an order of magnitude during thermal sterilization. Note. See ISO 11138-3 and ISO 11138-4.

4 General

4.1 This standard provides guidance on biological indicators, which are generally applicable to any sterilization process, including those not specified in the relevant standards. New sterilization process. 4.2 The use of biological indicators is usually in the program documentation and/or instructions. Note. The use of quality management systems such as ISO 13485 [7] generally meets the requirements of this clause. 4.3 Biological indicators should generally be combined with physical and/or chemical measurements to demonstrate the effectiveness of the sterilization process. When in the process of sterilization Physical and/or chemical variables are outside the specified limits, and the cause of the sterilizer's inability to obtain its process parameters should be evaluated and the problem Corrected. Systems and/or procedures should be established......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19972-2018_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19972-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19972-2018_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19972-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 19972-2018?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19972-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.