GB/T 19792-2012: Agricultural irrigation equipment -- Water-driven chemical injector pumps
Status: Valid

GB/T 19792: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 19792-2012279 Add to Cart 3 days Agricultural irrigation equipment -- Water-driven chemical injector pumps Valid
GB/T 19792-2005479 Add to Cart 4 days Agricultural irrigation equipment -- Water-driven chemical injector pumps Obsolete

Similar standards

GB/T 24674   GB/T 25409   GB/T 21962   GB/T 45789   GB/T 19794   GB/T 19797   

Basic data

Standard ID: GB/T 19792-2012 (GB/T19792-2012)
Description (Translated English): Agricultural irrigation equipment -- Water-driven chemical injector pumps
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: B91
Classification of International Standard: 65.060.35
Word Count Estimation: 12,123
Older Standard (superseded by this standard): GB/T 19792-2005
Quoted Standard: GB/T 7306.1; GB/T 7306.2; GB/T 9112; GB/T 9113; GB/T 9114; GB/T 9115; GB/T 9116; GB/T 9117; GB/T 9118; GB/T 9119; GB/T 9120; GB/T 9121; GB/T 9122; GB/T 9123; GB/T 9124; GB/T 1724.1; GB/T 1724.2; GB/T 1724.3; GB/T 1724.4; GB/T 1724.5; GB/T 1724.6; GB/T 172
Adopted Standard: ISO 13457-2008, MOD
Regulation (derived from): National Standards Bulletin No. 41 of 2012
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies a hydrodynamic fertilizer pesticide injection pump (hereinafter referred to as hydrodynamic injection pump) structure, technical requirements and test methods. The hydrodynamic injection pump irrigation system is used to inject fer

GB/T 19792-2012: Agricultural irrigation equipment -- Water-driven chemical injector pumps

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS65.060.35 B91 National Standards of People's Republic of China Replacing GB/T 19792-2005 Agricultural irrigation equipment Hydrodynamic fertilizer - pesticide injection pump (ISO 13457.2008, MOD) Issued on. 2012-12-31 2013-07-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard rule according to GB/T 1.1-2009 given draft. This standard replaces GB/T 19792-2005 "Agricultural irrigation equipment Hydrodynamic fertilizer - pesticide injection pump." This standard compared with GB/T 19792-2005, the main technical difference except outside editorial changes as follows. --- Adjusted normative references; --- GB/T 19792-2005 7.1 provision of irrigation water and injection water temperature of 5 ℃ ~ 50 ℃, the provisions of this standard 7.1 Irrigation Water injection and water temperature of 15 ℃ ~ 35 ℃; --- Anti-leak test, the water is injected into the negative pressure applied to the pump outlet, GB/T 19792-2005 provisions 5kPa ~ 10kPa, this Standard 10kPa (see 7.5.1); --- The standard delete GB/T 19792-2005 7.2 Sampling and acceptance criteria; --- Durability by the total running time of not less than 1000h should be changed to not less than 1150h (see 8.1). This standard uses redrafted law revision adopted ISO 13457.2008 "Agricultural irrigation equipment Hydrodynamic fertilizer - pesticide injection pump" (English Version). This standard and ISO 13457.2008 for the difference. --- On normative references, this standard has been adjusted technical differences, focus adjustments are reflected in Chapter 2, the specific Adjustments as follows. ● with the GB/T 7306.1 ~ 7306.2-2000 equivalent used in place of ISO 7-1.1994; ● with non-conformance with international standards equivalent to GB/T 17241.1 ~ 17241.7-1998 replaced ISO 7005- 2. 1988; ● Increase GB/T 9112 ~ 9124 "steel pipe flanges." The standard proposed by China Machinery Industry Federation. This standard by the National Standardization Technical Committee (SAC/TC201) Agricultural machinery centralized. This standard was drafted. Technical Research Center of Fluid Machinery Engineering, Jiangsu University, Chinese Academy of Agricultural Mechanization Sciences. The main drafters of this standard. Wang Yang, Zhang Xian wins, blue only, Li, Wang Xinkun, Zhao Liwei, the Qingjiang, Chen Chao. This standard replaces the standards previously issued as follows. --- GB/T 19792-2005. Agricultural irrigation equipment Hydrodynamic fertilizer - pesticide injection pump

1 Scope

This standard specifies the hydrodynamic fertilizer - pesticide injection pump (hereinafter referred to as hydrodynamic injection pump) structure, technical requirements and test methods for the moving of the water. Injection pumps for irrigation system to inject fertilizer - pesticides and fertilizers - pesticides including liquid manure, fertilizer and acid solution composition, pesticides, Grass like soluble pesticides. This standard applies to the temperature does not exceed 50 ℃, irrigation systems and water containing commonly used type and concentration of chemical fertilizers and pesticides running Hydrodynamic injection pump. This standard does not apply to reflux preventing means, it does not apply to irrigation systems inject fertilizer - pesticides Venturi hydrodynamic devices.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 7306.1 ~ 7306.2 55 ° sealing pipe thread (GB/T 7306.1 ~ 7306.2-2000, eqvISO 7-1.1994) GB/T 9112 ~ 9124 steel pipe flanges GB/T 17241.1 ~ 17241.7 cast iron pipe flanges (GB/T 17241.1 ~ 17241.7-1998, ISO 7005-2. 1988, NEQ)

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Hydrodynamic injection pumps water-driveninjectorpump Hydrodynamic fertilizer - pesticide injection pump water-drivenchemicalinjectorpump Only rely on irrigation water energy to drive the piston, turbine and other hydraulic equipment, irrigation system to inject fertilizer - liquid pesticides acting pump. 3.2 Nominal size nominalsize Series formula used to calibrate the water is fed to a conventional digital token pump size. Note. This size is equal to the moving of the water injection pump and irrigation system threaded connection, flange or other connecting device nominal size. 3.3 Minimum Operating Pressure minimumworkingpressure Pmin When the water injection pump move declared by the manufacturer to function properly minimum hydrodynamic injection pump inlet pressure. 3.4 Maximum operating pressure maximumworkingpressure Pmax When the water injection pump move declared by the manufacturer to function properly hydrodynamic injection pump inlet maximum pressure.
......