GB/T 18859-2016: Enclosed low-voltage switchgear and controlgear assemblies -- Guide for testing under conditions of arcing due to internal fault
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 18859-2016354 Add to Cart 3 days Enclosed low-voltage switchgear and controlgear assemblies -- Guide for testing under conditions of arcing due to internal fault Valid

Similar standards

GB/T 20936.4   CNCA C03-01   DL/T 259   

Basic data

Standard ID: GB/T 18859-2016 (GB/T18859-2016)
Description (Translated English): Enclosed low-voltage switchgear and controlgear assemblies -- Guide for testing under conditions of arcing due to internal fault
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K36
Classification of International Standard: 29.130.20
Word Count Estimation: 18,178
Date of Issue: 2016-12-13
Date of Implementation: 2017-07-01
Older Standard (superseded by this standard): GB/Z 18859-2002
Regulation (derived from): National Standard Announcement No.101 of 2016
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 18859-2016: Enclosed low-voltage switchgear and controlgear assemblies -- Guide for testing under conditions of arcing due to internal fault


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Enclosed low-voltage switchgear and controlgear assemblies - Guide for testing under conditions of arcing due to internal fault ICS 29.130.20 K36 National Standards of People's Republic of China Replace GB /Z18859-2002 Closed low voltage switchgear and control equipment In the case of an internal fault caused by an arc Test Guidance (IEC /T R61641..2014, IDT) 2016-12-13 released 2017-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB /Z18859-2002 "closed low-voltage switchgear and control equipment in the internal fault caused by arc Under the test guidelines ". This standard compared with GB /Z18859-2002, the main technical changes are as follows. --- to increase the concept of arc ignition protection zone, all the independent selection of live conductor to make the entire set of equipment into an arc Fire protection zone (see 3.9). - increase the use of arc level to define the different forms of protection of the arc failure. (1) personnel protection; (2) part of the complete set of equipment damage; For the limited use of complete sets of equipment (see 4.1). --- increase the case of arc failure, the complete set of equipment to provide two levels of personnel protection. (1) installed in the skilled technical staff can be close to the area (2) Complete sets of equipment installed in the general accessible area (see 4.2). - Increased arc ignited protection zone with minimum performance requirements (see Chapter 6). The use of this standard is equivalent to the use of IEC /T R61641..2014 "closed low-voltage switchgear and control equipment in the internal Test Guidance for Faults in the Case of Faults ". This standard has made the following editorial changes. --- Change IEC 60529 in 6.1, 6.3, 8.7 to IEC 60529. 1989, consistent with Chapter 2. This standard is proposed by China Electrical Equipment Industry Association. This standard by the National Low Voltage Switchgear and Control Equipment Standardization Technical Committee (SAC/TC266) centralized. The drafting unit of this standard. Tianjin Electric Science Research Institute Co., Ltd., Tianjin days of electronic control Power Distribution Co., Ltd., Sichuan Electric Co., Ltd., National Electric Power Distribution Equipment Quality Supervision and Inspection Center (Tianjin days of electronic control equipment Testing Co., Ltd.), Zhejiang Qunli Electric Co., Ltd., Zhejiang Three chen Electric Co., Ltd., Hangzhou Xin Mei complete sets of electrical manufacturing Co., Ltd., China Quality Certification Center, Chengdu Branch Star Power Electric Co., Ltd., Ningxia Li Cheng Electric Group Co., Ltd., Shanghai Jing Road Electric Co., Ltd. The main drafters of this standard. Zhang Lei, Liu Jie, Jia Lun, Jia Zhilei, Zhang Jing, Wang Binglin, Li Xiaojun, Chen Jian, Zhong Qiang, Niu Guangjun, Hu Wenying, Luo Julong, Zhang Jianguang. This standard was first released in January.2002, this time for the first revision. Closed low voltage switchgear and control equipment In the case of an internal fault caused by an arc Test Guidance

1 Scope

This standard gives guidance on the test methods of the complete set of equipment due to internal faults in the air caused by the arc. The purpose of this test is to assess the limitations of the complete set of equipment caused by the internal arc failure caused by personal injury, complete sets of equipment damage risk and continue to make With the ability to apply. The test procedure provided by this standard applies only to. --- Closed, floor-standing or wall-mounted low pressure in line with GB 7251.12 (complete sets of power switch and control equipment PSC complete sets of equipment) Complete sets of switchgear and control equipment. Note. This standard may be used as a reference document for other product arc fault tests, but taking into account the characteristics of other complete sets of equipment or products, the test procedure and Acceptance criteria. --- The door and cover of the complete set of equipment are closed and properly secured. This standard may be used as a guide when an agreement is reached between the user and the manufacturer in a different or worse case. The test procedure given in this standard should consider. --- the role of the cover, the door above the internal pressure over the impact; The thermal effect of the arc or arc root acting on the shell and the thermal effect of the injected hot and luminous particles. The test procedure given in this standard does not include. - other effects that can pose a hazard, such as toxic gases and noise; --- maintenance work, open the door or similar situation; --- close to the top and bottom of the complete set of equipment. The test is a voluntary test conducted by the manufacturer.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB 7251.1-2013 Low voltage switchgear and controlgear - Part 1. General (IEC 61439-1..2011, IDT) GB 7251.12-2013 Low-voltage switchgear and controlgear - Part 2. Complete sets of power switches and control equipment (IEC 61439-2..2011, IDT) IEC 60529. 1989 Enclosure protection class (IP code) [Degreesofprotectionprovidedbyenclosures (IPCode)] IEC 60529. 1989/AMD1..1999 IEC 60529. 1989/AMD2..2013

3 terms and definitions

GB 7251.12 Definitions and the following terms and definitions apply to this document.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 18859-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 18859-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 18859-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 18859-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.