Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 18575-2017 English PDF

US$168.00 ยท In stock
Delivery: <= 1 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 18575-2017: Shaking table test method for seismic performance of curtain wall
Status: Valid

GB/T 18575: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 18575-2017168 Add to Cart 1 days Shaking table test method for seismic performance of curtain wall Valid
GB/T 18575-2001159 Add to Cart 2 days Shaking table test method of earthquake resistant performance for building curtain wall Obsolete

Similar standards

GB/T 17742   DB/T 60   GB 50191   GB 17741   GB 55021   

Basic data

Standard ID: GB/T 18575-2017 (GB/T18575-2017)
Description (Translated English): Shaking table test method for seismic performance of curtain wall
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: P15
Classification of International Standard: 91.120.25
Word Count Estimation: 10,15
Date of Issue: 2017-10-14
Date of Implementation: 2018-09-01
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 18575-2017: Shaking table test method for seismic performance of curtain wall

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Shaking table test method for seismic performance of curtain wall ICS 91.120.25 P15 National Standards of People's Republic of China Replacing GB/T 18575-2001 Shake - wall seismic performance test method 2017-10-14 Published 2018-09-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 18575-2001 "shakedown test method for building curtain wall seismic performance," compared with GB/T 18575-2001 The main technical changes are as follows. --- Added analog seismic wave selection method and test report page style (see Appendix A and Appendix B); --- Supplemented curtain wall engineering test requirements, acceleration sensor measuring point layout requirements (see 4.4,5.1.2); --- Modify and adjust the standard of the main testing methods (see Chapter 5,.2001 edition Chapter 4). This standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This standard by the National Building Curtain wall Standardization Technical Committee (SAC/TC448) centralized. This standard is drafted by China Construction Metal Structure Association, China Academy of Building Research, Tongji University. Participated in the drafting of this standard. Guangdong Academy of Building Research Group Co., Ltd., Henan Institute of Building Research Limited Division, China Building Materials Inspection and Certification Group Co., Ltd., Shenyang Yuanda Aluminum Engineering Co., Ltd., Jiang Qinghai curtain wall systems engineering (Wuhan) have Co., Ltd., Shenzhen Fangda Jianke Group Co., Ltd., Shanghai Jianke Inspection Co., Ltd., Shanghai Construction Engineering Consulting Co., Ltd., deep Shenzhen Sanxin Technology Development Co., Ltd., Guangdong Jian Long Hardware Products Co., Ltd., Hui Fish (Taicang) Construction Anchor Bolts Co., Ltd., Hebei Olympic Run Shunda Window Industry Co., Ltd., River to create Group Co., Ltd. Dingtai Heng (Beijing) Building Materials Co., Ltd. The main drafters of this standard. Huangpi, Jiang Ren, Lu Wensheng, Huang Xiaokun, Li Qingxiang, Qian Wei, Liu Haibo, Yu Hua, Jiang Qinghai, Wen Lin, Xu Qin, Xi Shifang, Wang Feiyong, Du Wanming, Zhao Lin, Wei He Dong, Huang Zhangzhi, Huang Zheng. This standard replaces the standards previously issued as. --- GB/T 18575-2001. Shake - wall seismic performance test method

1 Scope

This standard specifies the terms and definitions shale test method of seismic performance of building walls, test requirements, test procedures, test data Reason and test report. This standard applies to the use of simulated seismic shaking table on the building curtain wall specimen dynamic response test to check, verify, evaluate the construction Building curtain wall seismic performance.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 21086 building walls GB 50011 Code for seismic design of buildings JGJ/T 101 Building seismic test code

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Building curtain wall simulation earthquake shaking table test earthquakesimulationshakingtabletestforcurtainwal Through the entry of the table shaking table seismic waves and artificial seismic waves, the simulation of the test objects (including building curtain wall full-scale test pieces and Its installation with a simulation test frame) role of the seismic test. 3.2 Seismic performance of building curtain walls seismicperformanceofcurtainwal Under the action of the prescribed earthquake, the performance of the curtain wall against earthquake action usually includes the carrying capacity of the curtain wall, deformation capacity and damage mode. 3.3 Displacement angle between story walls storydriftangleofcurtainwal The ratio of the horizontal displacement difference between the measuring points at the top and the bottom of the curtain wall specimen to the spacing between the measuring points.

4 test requirements

4.1 Shaker 4.1.1 Shaking table should be consistent with the provisions of JGJ/T 101, should be used with iterative correction function of low frequency large displacement numerical control analog seismic vibration Moving platform. 4.1.2 Shaker table size and space should be able to meet the simulation test frame and curtain wall specimen installation requirements. 4.1.3 Shaking Table Top load and anti-overturning ability should meet the test requirements.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 18575-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 18575-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically in 24 hours. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 18575-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 18575-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 18575-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18575-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.