GB/T 18294.5-2010 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18294.5-2010: Technical identification methods for fire -- Part 5: Gas chromatography-mass spectrometry analysis Status: Valid
Basic dataStandard ID: GB/T 18294.5-2010 (GB/T18294.5-2010)Description (Translated English): Technical identification methods for fire -- Part 5: Gas chromatography-mass spectrometry analysis Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C82 Classification of International Standard: 13.220.01 Word Count Estimation: 7,782 Date of Issue: 2011-01-14 Date of Implementation: 2011-06-01 Quoted Standard: GB/T 19267.7; GB/T 20162 Regulation (derived from): Announcement of Newly Approved National Standards No. 2 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 18294.5-2010: Technical identification methods for fire -- Part 5: Gas chromatography-mass spectrometry analysis---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Technical identdication methods for fire.Part 5. Gas chromatography-mass spectrometry analysis ICS 13.220.01 C82 National Standards of People's Republic of China Fire technology identification method Part 5. Gas chromatography - mass spectrometry Part 5. Gaschromatography-massspectrometryanalysis 2011-01-14 release 2011-06-01 Implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released ForewordGB/T 18294 "fire technology identification method" is divided into six parts. - Part 1. Ultraviolet spectroscopy; - Part 2. Thin layer chromatography; - Part 3. Gas Chromatography; - Part 4. High performance liquid chromatography; - Part 5. Gas chromatography - mass spectrometry; Part 6. Infrared spectroscopy. This part is part 5 of GB/T 18294. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part is made by the Ministry of Public Security of the People's Republic of China. This section is headed by the National Fire Safety Standardization Technical Committee Fire Investigation Subcommittee (SAC/TC113/SC11). This part of the drafting unit. Ministry of Public Security Tianjin Fire Research Institute. The main drafters of this section. Tian Guihua, Lu Zhibao, Deng Zhenyu, Liang Guofu, Geng Huimin. Fire technology identification method Part 5. Gas chromatography - mass spectrometry1 ScopeThis part of GB/T 18294 specifies the terms and definitions of gas chromatography-mass spectrometry (GC-MS) in fire technology identification. Test equipment, test conditions and test methods. This part applies to gasoline, kerosene, diesel, paint thinner and other fire scene common flammable liquid and its combustion residue identification.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 19267.7 Physical and chemical testing of microchemical evidence for criminal technology - Part 7. Gas chromatography - mass spectrometry GB/T .20162 Fire technology identification material extraction method3 terms and definitionsGB/T 19267.7 and GB/T .20162 and the following terms and definitions apply to this document. 3.1 Total ion chromatogram total ionchromatogram In the chromatographic conditions under which the flammable liquid is passed through a capillary column, the total ion current of each component obtained by mass spectrometry The intensity varies with the scan time. 3.2 Extraction of ion - flow chromatograms extractedionchromatogram A map of the characteristic ion peaks of the flammable liquid selected from the total ion chromatogram.4 test principleAfter the laboratory pretreatment to be analyzed samples, injected into the gas chromatography-mass spectrometry instrument, after a pair of analytical samples with good Good separation of the capillary column into the mass spectrum, the total ion chromatogram, using the total ion chromatogram and extraction of ion current chromatography The characteristic of the flammable liquid is determined qualitatively by distinguishing the characteristic peaks.5 test equipment5.1 Gas Chromatography - Mass Spectrometer A combination of a capillary chromatograph that separates flammable liquids and a mass spectrometer that identifies flammable liquids. 5.2 syringes 5.2.1 Liquid syringe. Volume injector in the range of 0.1 μL to 10.0 μL. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18294.5-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 18294.5-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18294.5-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18294.5-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |