GB/T 18175-2014 English PDFUS$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18175-2014: Determination of corrosion inhibition performance of water treatment agents -- Rotation specimen method Status: Valid GB/T 18175: Historical versions
Basic dataStandard ID: GB/T 18175-2014 (GB/T18175-2014)Description (Translated English): Determination of corrosion inhibition performance of water treatment agents -- Rotation specimen method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G76 Classification of International Standard: 71.040.40 Word Count Estimation: 8,828 Date of Issue: 7/8/2014 Date of Implementation: 12/1/2014 Older Standard (superseded by this standard): GB/T 18175-2000 Quoted Standard: GB/T603; GB/T 6682-2008; GB/T 15742; HG/T 3523 Adopted Standard: ASTM G31-1972(2004) Regulation (derived from): 2014 National Standards Bulletin No. 18 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the determination of corrosion inhibition performance of water treatment agents - Rotation specimen method with laboratory methods. This standard applies to the determination of the water treatment agent corrosion properties. GB/T 18175-2014: Determination of corrosion inhibition performance of water treatment agents -- Rotation specimen method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of corrosion inhibition performance of water treatment agents-Rotation specimen method ICS 71.040.40 G76 National Standards of People's Republic of China Replacing GB/T 18175-2000 Determination of corrosion inhibition performance of water treatment agents - Rotation specimen method Issued on. 2014-07-08 2014-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 18175-2000 "Determination of corrosion inhibition performance of water treatment agents - Rotation specimen method" and GB/T 18175-2000 Compared to the main technical changes are as follows. --- Test device from the water bath temperature control range "30 ℃ ~ 60 ℃" changed to "25 ℃ ~ 60 ℃", and added water bath circulating pump Bath temperature uniformity (see Chapter 5, 2000 edition 5.1); --- Rotary shaft by the speed accuracy ± 3% increased to ± 2% (see Chapter 5, 2000 edition 5.1); --- Test device continuous operation cycle from "200h above" was changed to "168h above" (see Chapter 5, 2000 edition 5.1); --- By the test solution temperature "can also be selected according to the actual needs of other temperature" to "or use within 25 ℃ ~ 60 ℃ temperature range of other Test solution temperature "(see 61, 2000 version 6.1.); --- Specimen from the lower end of the outlet point increase, "the specimen should not have bubble adhesion" requirements (see 66, 2000 version 6.7.); --- The number of parallel tests conducted by "For each test condition, should have the same test piece 4 ~ 6 parallel test" to "same entity Test conditions should be not less than three groups "(see 67, 2000 version 6.8.); --- Test period increased "or may need to make their own determination test cycle" (see 68, 2000 version 6.9.); --- Removed "according to test requirements, the choice of pre-film specimen can also be used without pre-film specimen" (2000 version 6.10); --- Pickling time the specimen processed by the "3min ~ 5min" to "about 30s" (see 79, 2000 version 7.8.); --- Remove the corrosion rate conversion table (the 2000 edition of Appendix B). The standard reference ASTMG31-1972 (2004) "laboratory corrosion test of metal impregnation" establishment. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee chemical water treatment chemicals Technical Committee (SAC/TC63/SC5) centralized. This standard is drafted by. Hao bright Chemical Research and Design Institute Co., Ltd. Nanjing Gyosui, Guangzhou City Special Order Pressure Equipment Inspection and Research Institute, Shanghai Future Enterprises Limited, Nalco (China) Environmental Technology Services Ltd., Shandong Taihe Water Treatment Ltd., China Petroleum and Chemical Corporation Beijing hospital north of Yanshan Branch, CNOOC Tianjin Chemical Research & Design Institute, Jiangsu Ke Lien Water purification Technology Co., Ltd., Shenzhen Industry Co., Ltd. Run water. The main drafters of this standard. Guoxi Min, Abolished, Chen Wei, Yang Lin, Wanghui Qi, Zhou Guoping, Liu Qiang, Li and students, Li Lin, Chi bow set. This standard replaces the standards previously issued as follows. --- GB/T 18175-2000. Determination of corrosion inhibition performance of water treatment agents - Rotation specimen method WARNING. Strong acids are used in this standard, alkali corrosive, should be used to avoid inhalation or contact with the skin. Splashed on him immediately with Plenty of water, seek immediate medical attention should be serious.1 ScopeThis standard specifies the determination of corrosion inhibition performance of water treatment agents - Rotation specimen method with laboratory methods. This standard applies to the determination of the water treatment agent corrosion properties.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 603 chemical reagent in test methods - Preparations with Laboratory use specifications and test methods GB/T 6682-2008 Analysis GB/T 15724 laboratory glassware beaker HG/T 3523 standard chemical treatment of cooling water corrosion test piece technical conditions3 Method summaryCorrosion Test Method for Rotation specimen is given under laboratory conditions, the mass loss of the test piece to calculate the corrosion rate and corrosion rate assessment Inhibition performance of water treatment agents.4 Reagents and materials4.1 standard reagents and water, unless otherwise specified, use only analytical reagent and in line with GB/T 6682-2008 in three water Provisions. 4.2 Test preparations and products required, did not indicate when the other requirements, according to GB /603 provisions of the preparation T. 4.3 acetone. 4.4 ethanol. 4.5 hydrochloric acid solution. 14. 4.6 Sodium hydroxide solution. 60g/L. 4.7 pickling solution. 1000mL hydrochloric acid solution was added 8g hexamethylenetetramine, dissolve and mix. Suitable for carbon steel test pieces. 4.8 Specimen. comply with HG/T 3523's.5 instruments and equipmentTest device (see Figure 1) shall meet the following requirements. --- Water bath temperature control range is 25 ℃ ~ 60 ℃, an accuracy of ± 1.0 ℃, water bath, hot water circulating through the pump, so water bath temperatures are First, the maximum temperature not more than 1.0 ℃; ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18175-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 18175-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18175-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18175-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 18175-2014?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18175-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |