Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 18136-2008 English PDF

US$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 18136-2008: AC high voltage electrostatic shielding clothing and test procedure
Status: Valid

GB/T 18136: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 18136-2008399 Add to Cart 3 days AC high voltage electrostatic shielding clothing and test procedure Valid
GB 18136-2000359 Add to Cart 3 days Laser guards Obsolete

Similar standards

GB 14866   GB 20653   GB/T 20097   GB 39800.10   GB 39800.11   GB 31420   

Basic data

Standard ID: GB/T 18136-2008 (GB/T18136-2008)
Description (Translated English): AC high voltage electrostatic shielding clothing and test procedure
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: C73
Classification of International Standard: 13.340.10
Word Count Estimation: 17,117
Date of Issue: 2008-09-24
Date of Implementation: 2009-08-01
Older Standard (superseded by this standard): GB 18136-2000
Quoted Standard: GB/T 1335.1; GB/T 6568; GB/T 14286
Regulation (derived from): National Standard Approval Announcement 2008 No.16 (Total No.129)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the technical requirements for the exchange of high-voltage electrostatic protective clothing, test methods and inspection rules. This standard applies to the rated voltage of 110 (66) kV ~ 750kV AC transmission line and substation inspection and ground operations personnel wearing protective clothing AC high voltage static electricity. Made according to the standard AC voltage electrostatic protective clothing may not be used, such as potential shielding clothing to use.

GB/T 18136-2008: AC high voltage electrostatic shielding clothing and test procedure

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
AC high voltage electrostatic shielding clothing and test procedure ICS 13.340.10 C73 National Standards of People's Republic of China Replacing GB 18136-2000 AC high voltage electrostatic protective clothing and test methods Posted 2008-09-24 2009-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 technical requirements 5 Test Method 2 10 6 Inspection Rules 7 type of clothes 11 8 Marking and packaging 11

Foreword

This standard replaces GB 18136-2000 "high voltage electrostatic protective clothing and test methods." This standard and GB 18136-2000 major changes and additions compared to the following. --- This standard modifies the scope of the original standard for the exchange of 10kV ~ 500kV, modified to apply to 110 (66) kV ~ 750kV; --- This standard increases the technical requirements for the exchange of 750kV voltage level of electrostatic protective clothing. The standard proposed by China Electricity Council. This standard by the National Standardization Technical Committee work and live under the jurisdiction responsible for the interpretation. This standard is mainly drafted by. State Grid Wuhan High Voltage Research Institute, Changsha Electric Power Bureau. The main drafters of this standard. Hu Yi, Shao Guiwei, Burke cold, Zhang Lihua, Yi-hui, Wang Linong, Liu Kai, Xu Ying. This standard replaces the standards previously issued as follows. --- GB 18136-2000. AC high voltage electrostatic protective clothing and test methods

1 Scope

This standard specifies the technical requirements for the exchange of high-voltage electrostatic protective clothing, test methods and inspection rules. This standard applies to the rated voltage of 110 (66) kV ~ 750kV AC transmission line and substation inspection and ground operations personnel AC high voltage electrostatic wear protective clothing. Made according to the standard AC high voltage static electricity may not be as protective clothing and other apparel potential shield.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 1335.1 and type of clothes man GB/T 6568 live working shielded Clothing (GB/T 6568-2008, IEC 60895.2002, MOD) GB/T 14286 live working tools and equipment term (GB/T 14286-2008, IEC 60743.2001, MOD)

3 Terms and Definitions

In addition to the terms GB/T 14286 provisions, the following terms and definitions apply to this standard. 3.1 With a conductive material and textile fibers blended woven into a cloth made of clothing in order to effectively protect the lines and substations for inspection and ground Industry personnel from the effects of high voltage alternating field. AC high voltage static set of protective clothing includes. shirt, pants, hat, gloves and shoes. 3.2 Used in line with GB/T 6568 in Technical indicators shield made of cloth tape (width 15mm double), set in sewing clothing, pants, hats, gloves On to make an electrical connection ministries. 4. Technical Requirements 4.1 clothing 4.1.1 Resistance clothing Cloth resistance shall not exceed 300Ω. 4.1.2 cloth shielding effectiveness AC high voltage electrostatic shielding effectiveness of protective clothing for different voltage levels should meet the requirements of Table 1. Table 1 shielding effectiveness for different voltage levels AC high voltage electrostatic protective clothing Apply voltage grade shielding effectiveness 500kV and below ≥28dB 750kV ≥30dB
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 18136-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 18136-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 18136-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 18136-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 18136-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18136-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.