GB/T 18114.5-2010 English PDFUS$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18114.5-2010: Chemical analysis methods of rare earth concentrates -- Part 5: Determination of aluminum oxide content -- Inductively coupled plasma atomic emission spectrometry Status: Valid GB/T 18114.5: Historical versions
Basic dataStandard ID: GB/T 18114.5-2010 (GB/T18114.5-2010)Description (Translated English): Chemical analysis methods of rare earth concentrates -- Part 5: Determination of aluminum oxide content -- Inductively coupled plasma atomic emission spectrometry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H14 Classification of International Standard: 77.120.99 Word Count Estimation: 6,654 Date of Issue: 1/14/2011 Date of Implementation: 11/1/2011 Regulation (derived from): Announcement of Newly Approved National Standards No. 2 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies Determination of the amount of rare earth concentrates alumina. This Standard is applicable to the determination of rare earth concentrates in the amount of alumina. Measuring range: 0. 50% ~ 8. 00%. GB/T 18114.5-2010: Chemical analysis methods of rare earth concentrates -- Part 5: Determination of aluminum oxide content -- Inductively coupled plasma atomic emission spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Chemical analysis methods of rare earth concentrates Part 5. Determination of aluminum oxide content Inductively coupled plasma atomic emission spectrometry ICS 77.120.99 H14 National Standards of People's Republic of China Methods for chemical analysis of rare earth concentrates Part 5. Determination of the amount of alumina Inductively Coupled Plasma Atomic Emission Spectrometry Part 5. Determinationofaluminumoxidecontent- Issued on. 2011-01-14 2011-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 18114 "Methods for chemical analysis of rare earth concentrates" is divided into 11 parts. --- Part 1. Determination of total rare earth oxide gravimetric method; --- Part 2. Determination of thorium oxide content; --- Part 3. Determination of calcium oxide content; --- Part 4. niobium oxide, zirconium oxide, titanium oxide content - Inductively coupled plasma atomic emission spectrometry; --- Part 5. aluminum oxide content - Inductively coupled plasma atomic emission spectrometry; --- Part 6. Determination of the amount of silica; --- Part 7. Determination of the amount of iron oxide dichromate method; --- Part 8. fifteen rare earth element oxide with components measured by inductively coupled plasma atomic emission spectrometry; --- Part 9. Determination of the amount of phosphorus pentoxide bismuth molybdenum blue spectrophotometric method; --- Part 10. Determination of moisture content - Gravimetric method; --- Part 11. Determination of the amount of fluorine EDTA titration. This is Part 5. This part of the National Standardization Technical Committee of rare earth (SAC/TC229) centralized. This section is Baotou Rare Earth Research Institute, China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting. This section was drafted by the Baotou Rare Earth Research Institute. This part of the Inner Mongolia Baotou Steel Rare Earth (Group) Hi-Tech Company, Ganzhou Qiandong Rare Earth Group Co., Ltd. participated in the drafting. The main drafters of this section. Liu Xiaojie, Li Yumei. The drafters of some of the participants. Cao Junjie, Yang Chunhong, Zhanggui Mei, Wen Bin Yao Nam Hung, FAN Jian new. Methods for chemical analysis of rare earth concentrates Part 5. Determination of the amount of alumina Inductively Coupled Plasma Atomic Emission Spectrometry1 ScopeGB/T 18114 provisions of this part of the determination of rare earth concentrates in the alumina content. This section applies to the determination of rare earth concentrates in the alumina content. Measuring range. 0.50% - 8.00%.2 principle of the methodSample with sodium hydroxide, sodium peroxide decomposition melted, remove thorium and rare earth separation of alkali, using matrix effect correction method in an acidic solution, at Argon plasma spectrometer for measuring the amount of alumina.3 Reagents3.1 sodium hydroxide. 3.2 sodium peroxide. 3.3 hydrochloride (ρ1.19g/mL). 3.4 hydrochloride (11). 3.5 standard aluminum stock solution. Weigh accurately 0.1000g high purity (purity > 99.99%), add water, 5mL and 10mL hydrochloric acid (3.3), Low heat to dissolve, removed, cooled to room temperature and transferred to 100mL volumetric flask, dilute with water to volume, and mix. This solution containing 1mL 1mg aluminum. 3.6 aluminum standard solution. accurate Pipette 5.00mL aluminum standard stock solution (3.5) in 100mL flask, add 2mL of hydrochloric acid (3.4), Dilute with water to volume, and mix. This solution 1mL containing 50μg aluminum. 3.7 Argon. [w (Ar) > 99.99%].4 Instrument4.1 Full Spectrum Direct Reading plasma emission spectrometer. 4.2 source. argon plasma light source, power is not less than 1.0kW.5 SampleThe sample size should be 5.1 to grind through the 0.074mm sieve. 5.2 The sample was 105 ℃ ~ 110 ℃ drying 2h, placed in a desiccator to cool to room temperature. Step 6 Analysis 6.1 Sample Weigh 0.5g sample (5), accurate to 0.0001g. 6.2 Determination of the number of Weigh two samples (6.1) parallel determination of the mean value. 6.3 blank test ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18114.5-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 18114.5-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18114.5-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18114.5-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 18114.5-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18114.5-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |