GB/T 18044-2008 English PDFUS$294.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18044-2008: Carpets -- Assessment of static electrical propensity -- Walking test Status: Valid GB/T 18044: Historical versions
Basic dataStandard ID: GB/T 18044-2008 (GB/T18044-2008)Description (Translated English): Carpets -- Assessment of static electrical propensity -- Walking test Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: W56 Classification of International Standard: 59.080.60 Word Count Estimation: 15,179 Date of Issue: 2008-12-30 Date of Implementation: 2009-09-01 Older Standard (superseded by this standard): GB/T 18044-2000 Quoted Standard: GB/T 6031-1998; ISO 1957; ISO 2424; ISO 9407-1991; GB/T 1410; ASTM D 394-1959 Adopted Standard: ISO 6356-2000, IDT Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the conditions under surveillance habits of various types of carpet static evaluation approach. Because of the potential generated with humidity, sole material, walking walking walking carpet surface and varies in different ways to change the results of this test result does not necessarily reflect the circumstances carpet laying the scene, but it can be for different types of performance blanket provides control and comparison. In the case needs to be graded or controversial, controlled conditions specified in this standard measurement procedures can be specified in the relevant grading criteria or controversial under mutually agreed controlled conditions measured. There may be circumstances need to be measured in the absence of control conditions appear in the laying of floor coverings such as field measurements. Adopt this standard require the use of equipment for the measurement principle, can wear shoes prescribed standard measurements, or use of the site as required wearing shoes relevant measure. GB/T 18044-2008: Carpets -- Assessment of static electrical propensity -- Walking test---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Carpets. Assessment of static electrical propensity. Walking test ICS 59.080.60 W56 National Standards of People's Republic of China GB/T 18044-2008/ISO 6356.2000 Replacing GB/T 18044-2000 Carpet Assessment of static electrical propensity - Walking test (ISO 6356.2000, Textilefloorcoverings- Assessmentofstaticelectricalpropensity-Walkingtest, IDT) Posted 2008-12-30 2009-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard is equivalent to international standards ISO 6356.2000 "textile floor coverings - Assessment of static electrical propensity - Walking test." The standard on the technical content of ISO 6356.2000 are identical, only made a small editorial changes as follows. --- Press Our carpet series standard naming convention, change the standard name, with "carpet" instead of "textile floor coverings"; --- "This International Standard" be replaced by "this standard"; "." --- With a decimal point instead of a comma as the decimal point, ""; --- Remove the preface of international standards, increase the standard of this preface. This standard replaces GB/T 18044-2000 "carpet-static performance evaluation Analogue walking test methods." The main difference compared with the standard GB/T 18044-2000 as follows. --- By the simulation method to the direct use of human walking method; --- Former method costs less time, while consuming and human walking on very stringent test conditions control. The Standard Appendix A, Appendix B, Appendix C, Appendix D and Appendix E are normative appendix. The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee carpet. This standard is drafted by. China Arts and Crafts Association of Professional Committee of the carpet. Participate in drafting unit. Tianjin Oriental Sapphire carpet research center. The main drafters. Zhang Yufen, Liu Chao, Chen Guisheng. GB/T 18044-2008/ISO 6356.2000 Carpet Assessment of static electrical propensity - Walking test1 ScopeThis standard specifies the conditions under the supervision of the various types of carpet electrostatic method of evaluating habits. Because of the potential generated with the wet Degree, sole material, travel blanket and walking people walking in different ways and change, the results of this study do not necessarily reflect the results to Situation blanket laying the scene, but it does provide controls and compare the performance of different types of carpet surface. In the case of the need for classification or disputed, as specified in this standard measurement procedure can be regulated by the relevant grading standards Given control conditions or under controversial conditions mutually agreed control measure. There may be no need to be measured under controlled conditions Amount, for example, in laying of floor coverings field measurements. Adopting the standards set forth in the equipment used to measure the principle can Wearing shoes under the standard measurement, use of the site or wearing shoes under the relevant measure.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 6031-1998 vulcanized rubber or thermoplastic rubber hardness measurement (idt ISO 48.1994) ISO 1957 Textile floor coverings mechanism for intercepting physical testing of sampling and sample ISO 2424 Textile floor coverings Glossary ISO 9407.1991 shoe size to determine the size and sign Mondopoint system Determination of volume resistivity and surface resistivity GB/T 1410 solid insulating material (GB/T 1410-2006, IEC 60093. 1980, IDT) Standard Test Method for wear-resistant rubber compound 1959. ASTMD3943 Terms and DefinitionsISO 2424 to determine the terms and definitions apply to this standard. Principle 4 When a person. Carpet a) on the subject; b) wearing the standards required by the shoe; c) in accordance with the way of walking; d) is monitored under atmospheric conditions; When walking, with respect to the earth potential (0 potential) potential difference at this time is generated is measured, and in order to evaluate the use of people in This process of carpet will produce shock due to static charge caused discomfort risk.5 device5.1 grounded metal plate Size of at least 2000mm × 1000mm. Warning. Use a metal plate on the ground floor or the entire floor is a metal plate in the lab, once access to the power Power lines would constitute disasters. It is recommended to protect against ground fault circuit interrupter devices are equipped with all of the power applied. GB/T 18044-2008/ISO 6356.2000 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18044-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 18044-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18044-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18044-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 18044-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18044-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |