GB/T 17764-2008: Hydrometers -- Principles of construction and adjustment
Status: Valid

GB/T 17764: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 17764-2008174 Add to Cart 3 days Hydrometers -- Principles of construction and adjustment Valid
GB/T 17764-1999239 Add to Cart 2 days Principles of construction and adjustment of glass hydrometers Obsolete

Similar standards

GB/T 18455   GB 18218   GB/T 16716.7   GB/T 45215   GB/T 45216   GB 12268   

Basic data

Standard ID: GB/T 17764-2008 (GB/T17764-2008)
Description (Translated English): Hydrometers -- Principles of construction and adjustment
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: A80
Classification of International Standard: 13.300
Word Count Estimation: 9,922
Date of Issue: 2008-09-18
Date of Implementation: 2009-09-01
Older Standard (superseded by this standard): GB/T 17764-1999
Quoted Standard: ISO 1768
Adopted Standard: ISO 387-1977, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard provides a variety of glass used to measure the density of the liquid density meter calibration structure and principles. This standard is used without a thermometer, hydrometer glass hydrometer. This standard applies to all kinds of glass used to measure the density of the liquid density meter.

GB/T 17764-2008: Hydrometers -- Principles of construction and adjustment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Hydrometers. Principles of construction and adjustment ICS 13.300 A80 National Standards of People's Republic of China GB/T 17764-2008/ISO 387. 1977 Replacing GB/T 17764-1999 Structure and principles of density meter calibration (ISO 387. 1977, IDT) Posted 2008-09-18 2009-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard corresponds to ISO 387. 1977 "--- densitometer calibration structure and principles" and ISO 387 is equivalent to the degree of consistency. This standard replaces GB/T 17764-1999 "glass hydrometers density meter structure and alignment principles." This standard compared with GB/T 17764-1999 main changes are as follows. --- This standard increased "relative density" (see 3.2) interpretation; --- The standard increase the surface tension affect the technical content of densitometer used (see Chapter 5 and Appendix A); --- This standard adds densitometer basic explanation of scale (see Appendix B). Appendix A of this standard is a normative appendix, Appendix B is an informative annex. This standard by National Instrument Standardization Technical Committee on Glass (SAC/TC178) centralized. This standard was drafted. People's Republic of China Guangdong Entry-Exit Inspection and Quarantine Bureau, China National Light Industry Product Quality Supervision and Inspection glass center. The main drafters of this standard. Song Wu Yuan, Chen Qiang, Yuan Chunmei, Xiaoda Hui, Lee Jun, ZHOU Ming-hui, Liu Jianbin, Ye Liang, Liang Meiqiong, Yueda Lei, Liu Yingfeng. This standard replaces the standards previously issued as follows. --- GB/T 17764-1999. GB/T 17764-2008/ISO 387. 1977 Structure and principles of density meter calibration

1 Scope

This standard specifies the structure and principles of calibration for various liquid glass density measurement density meter. This standard is used for the glass hydrometer density meter without a thermometer. This standard applies to all kinds of glass used to measure the density of a liquid density meter.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. ISO 1768 conventional numerical density meter --- glass volume expansion coefficient (for the development of liquid measurement table)

3 Terms and Definitions

3.1 3.1.1 scales should kilograms per cubic meter (kg/m3) in units of the indicated density (mass per unit volume). Grams per cubic centimeter (g/cm3) is One can accept the International System of Units (SI) units. NOTE. Appendix B explains the basic use density as a density meter scale advantages. 3.1.2 is not recommended for use is not based on the density scale. But allows the relative density of the water-based as scale, because it The relative density of species of scale unit widely used in national trade. 3.2 Where. ρ1 --- liquid density at a given temperature conditions T1; ρ2 --- under the conditions at a given temperature T2 density of pure water. 3.3 3.3.1 Standard reference temperature predetermined density meter should be 20 ℃. Note. Under certain environmental conditions, standard temperature densitometer can also choose 15 ℃ or 27 ℃. As tropical areas, the ambient temperature is always higher than 20 ℃, At this temperature the standard density meter is recommended to select 27 ℃. 3.3.2 The use of the relative density of the mark, by definition 3.2, the relative density of the standard reference temperature T1 and T2 should all 15.56 ℃ (60 ° F). 3.4 3.4.1 The surface tension calibration density meter, unless the requirements of high-precision, surface tension or should use a standard classification given in Appendix A Select the density meter is used. GB/T 17764-2008/ISO 387. 1977
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17764-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17764-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17764-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17764-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 17764-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17764-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.