Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 17680.12-2008 English PDF

US$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17680.12-2008: Criteria for emergency planning and preparedness for nuclear power plants -- Part 12: Planning, development, conduct and evaluation of nuclear emergency drills and exercises
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 17680.12-2008399 Add to Cart 3 days Criteria for emergency planning and preparedness for nuclear power plants -- Part 12: Planning, development, conduct and evaluation of nuclear emergency drills and exercises Valid

Similar standards

GB 39220   GB/T 17680.11   GB/T 17680.1   GB/T 17680.5   

Basic data

Standard ID: GB/T 17680.12-2008 (GB/T17680.12-2008)
Description (Translated English): Criteria for emergency planning and preparedness for nuclear power plants -- Part 12: Planning, development, conduct and evaluation of nuclear emergency drills and exercises
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: F77
Classification of International Standard: 27.120.20
Word Count Estimation: 17,136
Date of Issue: 2008-03-24
Date of Implementation: 2008-11-01
Quoted Standard: Announcement of Newly Approved National Standards No. 5, 2008 (No. 118 overall)
Adopted Standard: ANSI/ANS-3.8.7-1998, NEQ
Regulation (derived from): Announcement of Newly Approved National Standards No. 5, 2008 (No. 118 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the nuclear power plant emergency drills and exercises planning, preparation, implementation, and evaluation criteria, Unless otherwise stated herein, this section provides guidelines also apply to the various exercises and exercises. This section applies to the nuclear power plant operating unit nuclear emergency response organizations (hereinafter referred to as on-site emergency organization) emergency exercises and drills, nuclear power seat of the provincial nuclear emergency response organizations (hereinafter referred to as off-site emergency organizations) emergency exercises and drills may refer to.

GB/T 17680.12-2008: Criteria for emergency planning and preparedness for nuclear power plants -- Part 12: Planning, development, conduct and evaluation of nuclear emergency drills and exercises



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Criteria for emergency planning and preparedness for nuclear power plants Part 12. Planning, development, conduct and evaluation of nuclear emergency drills and exercises ICS 27.120.20 F77 National Standards of People's Republic of China Nuclear power plant emergency planning and preparedness for Part 12. Nuclear emergency exercises and drills Planning, preparation, implementation and evaluation Posted 2008-03-24 2008-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Plan 2 4.1 General Requirements 2 4.2 exercise class 3 Frequency of 4.3 exercise 3 4.4 Exercise 3 5 Prepare 5 5.1 Exercise of Management 5 5.2 training supervisor and the assessor of claim 6 5.3 timing and coordination 6 OK 7 5.4 Resources 5.5 Scenario 7 5.6 Exercise or exercise manual 9 Example 9 6 6.1 Introduction 9 Exercise 6.2 10 place in advance 6.3 Data provided 10 6.4 Monitoring and practice exercises 10 7 Assessment 11 7.1 General 11 Develop assessment criteria 7.2 11 7.3 Questions and discussion 11 Collect 12 7.4 files 7.5 Evaluation and Assessment Report 12 7.6 Summary Report 12 7.7 Corrective Action 12

Foreword

Currently, GB/T 17680 "nuclear power plant emergency planning and preparedness for" 12 divided into the following sections. --- Part 1. Fallen emergency planning zone; --- Part 2. Off-site emergency functions and organization; --- Part 3. Off-site emergency facilities functions and features; --- Part 4. off-site emergency planning and implementing procedures; --- Part 5. Keep off-site emergency response capacity; --- Part 6. site emergency response functions and organizations; --- Part 7. facility site emergency functions and features; --- Part 8. site emergency planning and implementing procedures; --- Part 9. Maintain site emergency response capabilities; --- Part 10. Nuclear power plant operating units for emergency radiological field monitoring, sampling and analysis criteria; --- Part 11. Off-site radiological assessment for emergency response time; --- Part 12. Nuclear emergency exercises and drills of planning, preparation, implementation and evaluation. This section is GB/T Part 1,217,680, which corresponds to American National Standard ANSI/ANS-3.8.7.1998 "Nuclear Emergency ahead Exercises and exercise planning, preparation, implementation and evaluation criteria. " This portion of the American National Standard ANSI/ANS-3.8.7.1998 unanimously The degree of non-equivalent. This part of the plan for the nuclear power plant emergency exercises and drills in preparation, implementation and evaluation provides detailed technical guidelines, there is a national Off laws, regulations and national standards GB/T 17680.5 "to maintain nuclear power plant emergency planning and preparedness for off-site emergency response capacity" And GB/T 17680.9 "to maintain nuclear power plant emergency planning and preparedness for emergency response capacity of the venue," added the technical. This part is proposed by the China National Nuclear Corporation. This part of the National Standardization Technical Committee centralized nuclear energy. This section was drafted by. Institute of Nuclear Industry Standardization. The main drafters of this section. Zhuo Feng official, Chen Zhu Zhou. Nuclear power plant emergency planning and preparedness for Part 12. Nuclear emergency exercises and drills Planning, preparation, implementation and evaluation

1 Scope

GB/T 17680 provisions of this part of the nuclear emergency exercises and drills planned nuclear power plant, preparation, implementation and evaluation criteria; in addition to special Do not explain those outside the guidelines set forth in this section applies to both exercise and practice. Nuclear power plants; This section applies to a nuclear power plant operating organization Nuclear Emergency Organization (hereinafter referred to as site emergency organization) emergency exercises and drills Local provincial nuclear emergency organization (hereinafter referred to as off-site emergency response organizations) emergency exercises and drills can be implemented by reference.

2 Normative references

The following documents contain provisions which, through reference GB/T 17680 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. Keeping GB/T 17680.5-1999 nuclear power plant emergency planning and preparedness for off-site emergency response capacity Keeping GB/T 17680.9-2003 nuclear power plant emergency planning and preparedness for emergency response capacity venue

3 Terms and Definitions

The following terms and definitions apply GB/T 17680 in this section. 3.1 Organized training or exercise to maintain or evaluate emergency response personnel to perform the skills and capabilities of a particular emergency response functions carried out Make. Exercise is usually divided into training exercises and evaluation exercises (also called single exercise) categories. 3.2 To test the effectiveness of contingency planning, emergency preparedness perfection, emergency response capacity and adaptability emergency personnel carried synergy Practice a simulated emergency response; it involves depending on the content and scope can be divided into individual exercise (evaluation exercises), Comprehensive Combined exercises and joint exercises; this section "exercise" mainly refers to Integrated exercises and joint exercises. 3.3 All or parts departments or units inside or outside the organization's collaborative emergency exercises conducted in accordance with a predetermined scenario exercises to check Comprehensive responsiveness test, evaluation of the emergency organizations. 3.4 Inside and outside the organization in accordance with the unified emergency exercise scenario, organized jointly exercise all or part of its departments or units carried out,
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17680.12-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17680.12-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17680.12-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17680.12-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.