Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 17466.24-2017 English PDF

US$559.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17466.24-2017: Boxes and enclosures for electrical accessories for household and similar fixed electrical installations -- Part 24: Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment
Status: Valid

GB/T 17466.24: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 17466.24-2017559 Add to Cart 5 days Boxes and enclosures for electrical accessories for household and similar fixed electrical installations -- Part 24: Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment Valid
GB 17466.24-2008879 Add to Cart 4 days [GB/T 17466.24-2008] Boxes and enclosures for electrical accessories for household and similar fixed electrical installations -- Part 24: Particular requirements for enclosures for housing protective devices and similar power consuming devices Obsolete

Similar standards

GB/T 4343.2   GB/T 3883.311   JB/T 10772   GB/T 17466.22   GB/T 17466.23   GB/T 17466.21   

Basic data

Standard ID: GB/T 17466.24-2017 (GB/T17466.24-2017)
Description (Translated English): Boxes and enclosures for electrical accessories for household and similar fixed electrical installations -- Part 24: Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K65
Classification of International Standard: 29.120.10
Word Count Estimation: 28,247
Date of Issue: 2017-07-31
Date of Implementation: 2018-02-01
Older Standard (superseded by this standard): GB/T 17466.24-2008
Quoted Standard: GB/T 5465.2-2008; GB/T 10963.1; GB/T 16916.21; GB/T 16917.21; GB/T 17466.1-2008; GB/T 20138
Adopted Standard: IEC 60670-24-2011, MOD
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the housing protection devices and other power supply electrical appliances shell logo, anti-electric shock protection, structural requirements, mechanical properties, electrical performance and other technical requirements. This standard applies to residential and similar electrical installations with residential protection devices and other power supplies, which are expected to use a rated voltage of not more than 440 V, input total load current not exceeding 125 A, maximum power consumption during normal use The capacity is stated by the manufacturer. These housings are intended to be installed in places where non-professionals can access, and electrical equipment intended for their combination is installed on site by a specialist (installer). They are expected to be installed at expected short-circuit currents of no more than 10 kA

GB/T 17466.24-2017: Boxes and enclosures for electrical accessories for household and similar fixed electrical installations -- Part 24: Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 24. Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment ICS 29.120.10 K65 National Standards of People's Republic of China Replacing GB/T 17466.24-2008 Household and similar fixed electrical installations Accessories Mounting Boxes and Enclosures Part 24. Residential Protection devices and other power consumption appliances shell special requirements fixedelectricalinstalations-Part 24.Particularrequirementsforenclosuresfor (IEC 60670-24.2011, MOD) 2017-07-31Published.2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 General Requirements 2 5 General description of the test 2 6 rating 3 7 Categories 3 8 logo 3 9 size 4 10 anti-shock protection 4 11 Grounding measures 5 Structure 12 13 anti-aging, anti-solid foreign body into and prevent harmful water 5 Insulation resistance and electrical strength 6 15 Mechanical strength 6 16 heat 6 17 Creepage distance, clearance and distance through sealant 6 18 Insulation material resistance to abnormal heat, flame-retardant 7 19 resistance to tracking 7 20 Corrosion resistance 7 21 electromagnetic compatibility 7 Appendix AA (informative) Instructions and calculations provided by the manufacturer to the operator on how to assemble the accessories in the GP enclosure 15 Appendix BB (informative) Instructions and calculation examples provided by the manufacturer to the operator on how to assemble accessories in the PD housing 22 References 24

Foreword

GB/T 17466 "Household and similar fixed electrical installations electrical enclosure and mounting box" is divided into the following sections. --- Part 1. General requirements; --- Part 2. Special requirements. ● Part 21. Particular requirements for mounting boxes and enclosures for suspension devices; ● Part 22. Particular requirements for junction boxes and enclosures; ● Part 23. Particular requirements for surface mount boxes and enclosures; ● Part 24. Particular requirements for enclosures for residential protective devices and other power consuming appliances. This section GB/T 17466 Part 24. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB/T 17466.24-2008 "Household and similar fixed electrical installations electrical accessories mounting box and housing Part 24. Particular requirements for housings for residential protective devices and similar power supply devices ". This section compared with GB/T 17466.24-2008, the main technical changes are as follows. --- In accordance with IEC 60670-24.2011 standard name changes, the standard name from the "household and similar fixed electrical installations Electrical Accessories Mounting Boxes and Enclosures Part 24. Particular Requirements for Enclosures for Residential Protective Appliances and Similar Power Consumption Devices Seek to be amended to "Household and similar fixed electrical installations electrical enclosures Installation boxes and enclosures Part 24. Residential protection Particular requirements for housings for appliances and other power consuming appliances "; --- Chapter 1 added does not apply to GB/T 7251 standard low-voltage switchgear and control equipment, nor does it apply to Inlet port panel that is or is not part of the power distribution box; --- According to China's supply voltage level, the expected use of the rated voltage in Chapter 1 from not more than 400V to not more than 440V; --- Chapter 2 added four normative references GB/T 10963.1, GB/T 16916.21, GB/T 16917.21, GB/T 20138; --- Chapter 3 increased the definition of 3.101,3.102,3.103,3.104, revised 3.106 "rated current" definition; --- Removed 7.101.1 "According to the fire-resistant insulating materials (Chapter 18)" category, an increase of 7.101 "empty shell", 7.102 "basic Shell "classification; --- 8.1 added d) neutral dedicated terminal, f) connected to the protective conductor ground terminal, o) the classification of the housing based on the logo requirements; --- 8.101 added according to the type of different manuals and/or documents required shell data; --- Increased 12.102; --- 13.2 Replenishment of the IP code with the lid closed; --- Chapter 101 adds a common shell (GP shell) requirements; --- Added Chapter 102; --- Modify the appendix AA entitled "Manufacturers provide instructions to the operator how to assemble the accessories in the GP housing and calculation of example"; --- Added Appendix BB. This section uses the redrafted law to amend the use of IEC 60670-24.2011 "Household and similar fixed electrical installations electrical accessories Enclosures and enclosures - Part 24. Particular requirements for enclosures for residential protective devices and other power consuming appliances ". This part of IEC 60670-24.2011 technical differences and the reasons are as follows. --- On the normative references, this section made a technical difference with the adjustment to adapt to China's technical conditions, adjust the situation Concentration reflected in the second chapter "Normative references", the specific adjustments are as follows. ● Graphical symbols for electrical equipment using GB/T 5465.2-2008 Part 2. Graphical symbols (IEC 60417DB. 2007, IDT) instead of IEC 60417; ● With GB/T 10963.1 electrical accessories for household and similar places overcurrent protection circuit breaker Part 1. For the exchange Flow circuit breaker (GB/T 10963.1-2005, IEC 60898-1.2002, IDT) instead of IEC 60898-1; ● With GB/T 16916.21 household and similar purposes without overcurrent protection residual current operated circuit breakers (RCCB) Part 21. General rules Applicability to RCCBs whose operating function is independent of supply voltage (GB/T 16916.21- 2008, IEC 61008-2-1.1990, IDT) instead of IEC 61008-2-1; ● With GB/T 16917.21 household and similar purposes with overcurrent protection residual current operated circuit breaker (RCBO) Section 21. General rules Applicability of RCBOs whose operating function is independent of supply voltage (GB/T 16917.21- 2008, IEC 61009-2-1.1991, IDT) instead of IEC 61009-2-1; ● with GB/T 20138 electrical equipment enclosure external mechanical impact protection class (IK code) (GB/T 20138- 2006, IEC 62262.2002, IDT) instead of IEC 62262; --- For product use ambient temperature, IEC 60670-24.2011 Chapter 1 states that "after the installation, in line with the shell of this section, Suitable for usually not more than 25 ℃, occasionally 35 ℃. "Taking into account the geographical location of our country, the actual natural climate ring The distribution of ambient temperature, the south of the Yangtze River in the sub-humid tropics and humid areas of the annual average temperature and maximum temperature is higher, wet Degree is bigger. Therefore, this part of the ambient temperature was revised as "suitable for usually not exceeding 35 ℃, and occasionally will reach 40 ℃"; --- According to China's supply voltage level, the expected use of the first chapter of the rated voltage from not more than 400V to not more than 440V. This section made the following editorial changes. --- According to the relevant provisions of GB/T 1.1, in Chapter 1 "Scope" added "GB/T 17466 provisions of this part of the residential protection Devices and other power consumption appliances shell markings, anti-shock protection, structural requirements, mechanical properties, electrical properties and other technologies Claim. "; --- Remove some of IEC 60670-24.2011 applicable to other countries of the Notes, such as Chapter 1 Note 2, Note 3; Note 1 in Table 1, Note 102; Note for 13.2; Note for Note 12.101; Note for Note 13.2. This part is proposed by China Electrical Equipment Industry Association. This part of the National Electrical Accessories Standardization Technical Committee (SAC/TC67) centralized. This part of the drafting unit. China Electric Apparatus Research Institute Co., Ltd., Legrand Low Voltage (Wuxi) Co., Ltd., Zhejiang Hengtai Electrical Limited, Flying Eagle Electric Group Co., Ltd., Yuehua Holdings Group Co., Ltd., Weikai Testing Technology Co., Ltd., Ningbo Aike Lighting Co., Ltd. Limited, Naisi Electric (Jiaxing) Co., Ltd., Guangzhou Panyu Tianhong Industrial Development Co., Ltd. The main drafters of this section. Cai Jun, Liu Bo, Fu Kai, Zhou Yi, Zheng Wei, Wang Sheng, Jiang Jiulong, Guo Xiaoying, Shi Jiejun, Li Jingsong, Luo Shiming, Zhang Lirong. This part replaces the standards previously issued as. --- GB/T 17466.24-2008. Household and similar fixed electrical installations Accessories Mounting Boxes and Enclosures Part 24. Residential Protection devices and other power consumption appliances shell special requirements

1 Scope

GB/T 17466.1-2008 This clause is replaced by the following. GB/T 17466 provisions of this part of the housing protection devices and other power consumption appliances shell markings, protection against electric shock, the structure to Seeking, mechanical performance, electrical performance and other technical requirements. This section applies to household and similar fixed electrical installations of residential protection devices and other power consumption appliances, the expected amount of use Constant voltage does not exceed 440V, the total input current does not exceed 125A, the maximum power consumption in normal use by the manufacturer. These housings are intended to be installed in places accessible to non-professionals and the electrical equipment intended to be combined with them is supplied by a professional (installer Staff) installed on site. They are expected to be installed where the expected short-circuit current does not exceed 10kA unless they have a cut-off current not exceeding the 17kA limit Current protection equipment. After installation, housings in accordance with this standard are suitable for applications where the temperature does not normally exceed 35 ° C and occasionally reach 40 ° C. Within 24 hours, the maximum 40 ℃ and the lowest -5 ℃ ambient temperature used. Integral with electrical components and provide protection against external influences (eg mechanical impact, solid foreign matter or water ingress) Enclosure, should be in line with the relevant standards of enclosure protection. This section does not apply to GB/T 7251 as defined in the low-voltage switchgear and control equipment, nor is it or not power distribution Part of the inlet box panel. Note Inlet port panels are a set of modules consisting of a panel or enclosure with instrumentation and/or primary access. Inlet panel to meet their needs Standard or local supplier requirements.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 5465.2-2008 Graphical symbols for electrical equipment - Part 2. Graphical symbols (IEC 60417DB.2007, IDT) GB/T 10963.1 Electrical Accessories Overcurrent protective circuit breakers for household and similar places - Part 1. Circuit breakers for communication (GB/T 10963.1-2005, IEC 60898-1.2002, IDT) GB/T 16916.21 household and similar purposes without overcurrent protection residual current operated circuit breaker (RCCB) Part 21 General rules Applicability of RCCBs with independent operating voltage and supply voltage (IEC 61008-2-1). 1990, IDT) Residual current operated circuit breakers (RCBO) with overcurrent protection for household and similar purposes - Part 21. GB/T 16917.21. General rules Applicability of RCBOs independent of operating voltage and supply voltage (GB/T 16917.21-2008, IEC 61009-2-1.1991, IDT) GB/T 17466.1-2008 Household and similar fixed electrical installations Electrical Accessories Mounting box and housing Part 1. General
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17466.24-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17466.24-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17466.24-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17466.24-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 17466.24-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17466.24-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.