HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (10 Aug 2025)

GB/T 17147-2012 English PDF

US$349.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17147-2012: Measurement of audio-frequency noise voltage level in sound broadcasting
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 17147-2012English349 Add to Cart 3 days [Need to translate] Measurement of audio-frequency noise voltage level in sound broadcasting Valid GB/T 17147-2012
GB/T 17147-1997English359 Add to Cart 3 days [Need to translate] Measurement of audio-frequency noise voltage level in sound broadcasting Obsolete GB/T 17147-1997

PDF similar to GB/T 17147-2012


Basic data

Standard ID GB/T 17147-2012 (GB/T17147-2012)
Description (Translated English) Measurement of audio-frequency noise voltage level in sound broadcasting
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard M60
Classification of International Standard 33.160.01
Word Count Estimation 15,172
Older Standard (superseded by this standard) GB/T 17147-1997
Adopted Standard ITU-R BS.468-4-2002, IDT
Regulation (derived from) National Standards Bulletin No. 13 of 2012
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the sound broadcasting of audio noise level measurement method to measure the required characteristics of weighted networks, the characteristics of measuring instruments and methods of measurement. This standard applies to audio pr

Similar standards

GY/T 268.2   GY/T 220.2   GB/T 28438.2   GB/T 34999   GB/T 31001   

GB/T 17147-2012: Measurement of audio-frequency noise voltage level in sound broadcasting

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS33.160.01 M60 National Standards of People's Republic of China Replacing GB/T 17147-1997 Sound broadcasting audio noise level measurement (ITU-RBS.468-4.2002, IDT) Issued on. 2012-10-01 2012-06-29 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 Label 1 2 3 Measurement 1 4 5 measurement results presentation Fixed impedance Appendix A (normative) Weighted network implementation 6 Appendix B (normative) unweighted noise level measuring 7 References 8

Foreword

This standard rule according to GB/T 1.1-2009 given draft. This standard replaces GB/T 17147-1997 "sound broadcasting audio noise level measurements." This standard and GB/T 17147-1997 compared to the main technical changes are as follows. --- Weighted network in the frequency response 31500Hz by -47.7dB to -42.7dB (see Table 1); --- Adds a new level to achieve noise measurement weighting network circuit (see Appendix A). This standard uses the translation method is equivalent to using ITU-RBS.468-4.2002 "sound broadcasting audio noise level measurements." This standard made the following editorial changes. --- Increasing the Code chapter; --- Increased by reference. This standard was proposed by the State Administration of Radio, Film and Television. This standard by the National Film and Television Broadcasting Standardization Technical Committee (SAC/TC239) centralized. This standard was drafted. the State Administration of Radio, Film Radio and Television Planning Institute. Drafters of this standard. any instrument, Marvin, Cui Junsheng, Xiao Hui, Zhang Qian. Sound broadcasting audio noise level measurement

1 Scope

This standard specifies the sound broadcasting audio noise level measurement method for the desired weighting network features, characteristics and measurement instruments Measurement methods. This standard applies to audio production, sound recording and reproducing system and audio broadcasting system measurement noise level.

2 Code

The following codes apply to this document. dBqps Taken as a reference voltage of 0.775V RMS, quasi-peak noise meter with a weighted measure (sound program transmission weight), expressed in decibels of the absolute Voltage level. [GB/T 3383-1982,2.12]

3 Measurement Methods

3.1 weighted network Measurements should be selected in line with the requirements of this quasi-peak meter, such as the use of weighted networks, it should also be used in line with the requirements of this weighting The internet. Figure 1 shows the circuit diagram of the weighting network, Figure 2 shows the nominal frequency weighting network response curve. Table 1 shows at different frequencies Response values. Tolerance response curve and the nominal curve and weighted by the amplifier network of measuring equipment between FIG. 3, Table The last column gives 1. When used with 3.1 audio noise weighting network measurements, measuring instruments comply with 3.2 should be a quasi-peak table using any What other instruments (such as the root mean square value tables) for such measurements would cause the measured signal to noise ratio is not directly related to the use of the standard instrument characteristics The table compares the measured SNR. Instrumentation (including weighting network) at 1kHz at calibration, see 3.2.6.

1 simple form of weighting network

Component values \u200b\u200btolerance and maximum 1% tolerance (1000Hz 10000Hz in the Q value of not less than 200, to meet given in Table 1 And the difference between the response of 6300Hz at, or by changing capacitor 33.06nF more precisely adjusted through the use of active filter).
......