Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 16915.7-2017 English PDF

US$339.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 16915.7-2017: Switches for household and similar fixed electrical installations -- Part 2-6: Particular requirements for fireman switches for exterior and interior signs and luminaires
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 16915.7-2017339 Add to Cart 4 days Switches for household and similar fixed electrical installations -- Part 2-6: Particular requirements for fireman switches for exterior and interior signs and luminaires Valid

Similar standards

GB/T 42407   GB/T 20138   GB/T 5959.41   GB/T 16915.2   GB/T 16915.1   GB/T 16915.4   

Basic data

Standard ID: GB/T 16915.7-2017 (GB/T16915.7-2017)
Description (Translated English): Switches for household and similar fixed electrical installations -- Part 2-6: Particular requirements for fireman switches for exterior and interior signs and luminaires
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K60
Classification of International Standard: 29.120.40
Word Count Estimation: 17,158
Date of Issue: 2017-07-31
Date of Implementation: 2018-02-01
Quoted Standard: GB/T 16915.1-2014; GB/T 2423.55-2006; GB/T 5465.2-2008; GB/T 16927.1-2011; GB/T 20138-2006
Adopted Standard: IEC 60669-2-6-2012, MOD
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the classification requirements, marking, structural requirements, mechanical properties, electrical performance and other technical requirements for external and internal identification and lighting fire switches. This standard applies to AC, low voltage circuits with rated voltage not exceeding 440 V and rated current not exceeding 125 A for disconnecting external and internal marking and lighting (eg, neon signage). Replace paragraph 7 and note 6 with the following modifications. Meet the requirements of the fire switch for the temperature range of -25 �� ~ 70 ��.

GB/T 16915.7-2017: Switches for household and similar fixed electrical installations -- Part 2-6: Particular requirements for fireman switches for exterior and interior signs and luminaires


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Switches for household and similar fixed electrical installations.Part 2-6. Particular requirements for fireman "" s switches for exterior and interior signs and luminaires ICS 29.120.40 K60 National Standards of People's Republic of China Switches for household and similar fixed electrical installations Part 2-6. External or internal marking and lighting Use the special requirements of fire switch Part 2-6.Particularrequirementsforfireman'sswitchesforexterior (IEC 60669-2-6.2012, Switchesforhousehold and similarfixedelectrical instalations-Part 2-6.Particularrequirements-Fireman'sswitchesfor exteriorand agenciesigns andluminaires, MOD) 2017-07-31Published.2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1

4 General requirements

5 General description of the test 2 6 rating 2 7 Categories 2 8 logo 2 9 dimensional inspection 3 10 anti-shock protection 3 11 Grounding measures 3 12 terminal 3 13 Structural requirements 6 Switch mechanism 8 15 Anti-aging, protection provided by the switch housing and moisture protection 8 Insulation resistance and electrical strength 8 17 temperature rise 9 18 off capacity 9 19 Normal operation 9 20 mechanical strength 10 21 heat-resistant 22 screws, current-carrying parts and connections 10 Creepage distance, clearance and piercing sealant distance 10 24 Insulation resistance to abnormal heat, flame and tracking resistance 10 25 rust 11 Electromagnetic Compatibility (EMC) Requirements 11 Reference 13

Foreword

GB/T 16915 "Household and similar fixed electrical installations switch" is divided into the following sections. --- Part 1. General requirements; --- Part 2. Special requirements ● Part 2-1. Particular requirements for electronic switches; ● Part 2-2. Particular requirements for electromagnetic remote control switches; ● Part 2-3. Delay switch special requirements; ● Part 2-4. Particular requirements for disconnectors; Part 2-5 Switches and related accessories for residential and building electronic systems (HBES); ● Part 2-6. Particular requirements for fire protection switches for external or internal marking and lighting purposes. This section GB/T 16915 Part 2-6. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the redrafted law to amend the use of IEC 60669-2-6.2012 "Household and similar fixed electrical devices switch Part 2-6. Particular requirements for external or internal signs and lighting fire switches. " This part of IEC 60669-2-6.2012 technical differences and the reasons are as follows. --- On the normative references, this section made a technical difference with the adjustment to adapt to China's technical conditions, adjust the situation Concentration reflected in the second chapter "Normative references", the specific adjustments are as follows. ● Added GB/T 2423.55-2006 Environmental Testing for Electrical and Electronic Products Part 2 according to the reference conditions Test Eh. Hammer test (IEC 60068-2-75.1997, IDT); ● According to the reference, an increase of GB/T 5465.2-2008 graphical symbols for electrical equipment Part 2. Graphical symbols (IEC 60417DB.2007, IDT); ● Switches using GB/T 16915.1-2014 household and similar fixed electrical installations Part 1. General requirements (IEC 60669-1.2007, MOD) instead of IEC 60669-1.1998 A1.1999 A2.2006; ● Added GB/T 16927.1-2011 high-voltage test technology Part 1 according to the reference conditions. General Definitions and Tests Requirements for inspection (IEC 60060-1.2006, MOD); ● With GB/T 20138-2006 electrical equipment enclosure external mechanical impact protection class (IK code) (IEC 62262. 2002, IDT) instead of IEC 62262. This section made the following editorial changes. --- According to the relevant provisions of GB/T 1.1, in Chapter 1, "Scope" added "GB/T 16915 provisions of this part of the external and internal Ministry of identification and lighting with the fire switch classification, marking, structural requirements, mechanical properties, electrical performance and other technical requirements "; --- 8.2 added the neon sign; --- Remove some of IEC 60669-2-6.2012 applicable to other countries of the Notes, such as notes in Chapter 1 101,103,13.108 Note 101 and so on; --- Because this part of the need to be used in conjunction with GB/T 16915.1-2014, according to GB/T 16915.1-2014 table number repair The serial numbers of the tables in this part have been changed accordingly. For example, Table 2 in 12.2.1 should be changed to Table 3 and Table 20 in Chapter 23 should be changed to Table 23. This part is proposed by China Electrical Equipment Industry Association. This part of the National Electrical Accessories Standardization Technical Committee (SAC/TC67) centralized. This part of the drafting unit. China Electric Apparatus Research Institute Co., Ltd., Zhejiang Chint Construction Electric Co., Ltd., Hangzhou Hongyan Electric Co., Ltd. Company, Clipsal Industrial (Huizhou) Co., Ltd. Shenzhen Branch, Ningbo Bulls Electric Co., Wei Kai Detection Technology Co., Ltd., Beijing Branch Can Bo Electronic Technology Co., Ltd., Siemens (China) Co., Ltd. Shanghai Branch, Guangzhou Panyu Tianhong Industrial Development Co., Ltd. Division, Huizhou Electric Road Technology Co., Ltd. The main drafters of this section. Cai Jun, Liu Yuanfang, Li Hongkuang, Gong Zhilei, Ruan Liping, a high hope, Shao Jing Jiang, Charles Chappen, Richard Tat, Xu Qiang Yun, Hu Lanfang, Shen members, pro-Huang Shun, Chen Kejie. Switches for household and similar fixed electrical installations Part 2-6. External or internal marking and lighting Use the special requirements of fire switch

1 Scope

GB/T 16915.1-2014 This chapter applies as follows. Paragraph 1 and paragraph 2 should read as follows. GB/T 16915 provisions of this part of the external and internal signs and lighting fire switch classification, marking, structural requirements, mechanical Can, electrical performance and other technical requirements. This section applies to alternating current, rated voltage does not exceed 440V, rated current does not exceed 125A, used to disconnect the external and internal identification and Lighting switches (eg, neon signs) for low voltage circuits. Paragraph 7 and note 6 apply mutatis mutandis. Meet the requirements of this section of the fire switch for the temperature range of -25 ℃ ~ 70 ℃. Note 101. The fire switch is designed for overvoltage category III and is used in an environment that meets GB/T 16935.1 Environmental Pollution Degree 2.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 16915.1-2014 Household and similar fixed electrical installations - Part 1. General requirements (IEC 60669- 1.2007, MOD) This chapter applies mutatis mutandis. increase. GB/T 2423.55-2006 Environmental testing for electric and electronic products Part 2. Environmental test Eh. Hammer test (IEC 60068-2-75.1997, IDT) GB/T 5465.2-2008 Graphical symbols for electrical equipment - Part 2. Graphical symbols (IEC 60417DB.2007, IDT) GB/T 16927.1-2011 High voltage test techniques - Part 1. General definitions and test requirements (IEC 60060-1.2006, MOD) GB/T 20138-2006 Protection degree (IK code) of electrical equipment enclosure to external mechanical impact (IEC 62262.2002, IDT)

3 Terms and definitions

GB/T 16915.1-2014 defined and the following terms and definitions apply to this document. 3.101 Fire switch fireman'sswitch Switch for emergency disconnection of lighting.

4 General requirements

GB/T 16915.1-2014 of this chapter apply.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 16915.7-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 16915.7-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 16915.7-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 16915.7-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.