GB/T 1660-2008 English PDFUS$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 1660-2008: Determining the kinematic viscosity of plasticizers Status: Valid GB/T 1660: Historical versions
Basic dataStandard ID: GB/T 1660-2008 (GB/T1660-2008)Description (Translated English): Determining the kinematic viscosity of plasticizers Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G70 Classification of International Standard: 71.100; 83.040.30 Word Count Estimation: 11,187 Date of Issue: 2008-06-18 Date of Implementation: 2009-02-01 Older Standard (superseded by this standard): GB/T 1660-1982; GB/T 1661-1982 Quoted Standard: GB/T 265; GB/T 266; GB/T 514; GB 1922-2006 Regulation (derived from): National Standard Approval Announcement 2008 No.10 (Total No.123) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard applies to the kinematic viscosity measured at 1 cps to 15, 000 cps viscosity liquid plasticizer movement. When a viscosity greater than 15, 000 cps, 's products should be used viscometer 5. 0mm or 6. 0mm diameter. B method for the determination of kinematic viscosity of liquid plasticizer kinematic viscosity of 10, 000 cps or less. GB/T 1660-2008: Determining the kinematic viscosity of plasticizers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Determinating the kincmatic viscosity of plasticizers ICS 71.100; 83.040.30 G70 National Standards of People's Republic of China Replacing GB/T 1660 ~ 1661-1982 Determination of kinematic viscosity plasticizer Posted 2008-06-18 2009-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard replaces GB/T 1660-1982 "Determination of kinematic viscosity of plasticizers (product's method)" and GB/T 1661-1982 "plasticizer transport Determination of dynamic viscosity (Engler method). " This standard and GB/T 1660-1982 and GB/T 1661-1982 no technical difference. Appendix A of this standard is an informative annex. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee rubber chemical additives and rubber Technical Committee. This standard is drafted by. Shanxi Institute of Chemical Engineering. The main drafters of this standard. Anfang, Zhang Yulan. This standard replaces the standards previously issued as follows. --- GB/T 1660-1979, GB/T 1660-1982. --- GB/T 1661-1979, GB/T 1661-1982. Determination of kinematic viscosity plasticizer1 ScopeThis standard applies to Method A ~ 1 cps measured kinematic viscosity of the liquid plasticizer PCT kinematic viscosity 15,000 poise, when the viscosity is greater than When 15,000 cps, should be used in product's viscometer 5.0mm or 6.0mm diameter. B method is suitable for the kinematic viscosity of 10,000 centipoise Determination of kinematic viscosity of liquid plasticizer poise or less.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 265 Petroleum products - Determination of kinematic viscosity and calculation of dynamic viscosity GB/T 266 Petroleum products Engler viscometry GB/T 514 Petroleum products test glass liquid thermometer technical conditions GB 1922-2006 oil paints and cleaning solvents3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 At the same temperature, dynamic viscosity of the liquid and its specific density, called kinematic viscosity. Units of poise or centipoise or cP represented by Poise. 3.2 At a predetermined temperature, the outflow from the Engler viscometer 200mL required time (s) with the same volume of distilled water at 20 ℃ flowing Engler viscometer The time required (s) ratio, called the Engler viscosity. The unit as a condition of use oE expressed.4 Reagents and solutions4.1 solvent oil (in line with GB 1922-2006). 4.2 petroleum ether [8032-32-4]. 4.3 ethanol [67-17-5]. 4.4 ether [60-29-7]. 4.5 Determination of the viscosity before the plasticizer must be viscometer with a solvent oil, light petroleum ether or gasoline washed with ether, if there is dirt viscometer, Then carefully washed with chromic acid lotion, etc., distilled water or ethanol, then placed in a drying oven or hot air filtered through cotton dry. 4.6 Use Load plasticized product's viscosity meter (see Figure 1) the determination of kinematic viscosity, the inner diameter to meet the requirements of clean and dry capillary viscometer Agent. The hose before loading on the support tube 6, and stick a finger tube spout body B, while an inverted viscometer. The tube was then inserted into the body 4 Container containing the sample, in which case the use of rubber ball, water pump or other vacuum sucked liquid marking b, taking care not to make the tube body 4, Expansion of parts 2 and 3 of the liquid air bubbles or cracks, when the liquid level reaches marking b, instituted viscometer from the container and quickly returned to normal status. While the excess sample tube barrel end of the outer wall 4 of the stained cleaned it off and remove the hose sleeve in the tube body 4 from the manifold 6. 4.7 will be equipped with viscometer immersed in a sample ready in advance of the thermostat, and the viscometer with clips fixed on the bracket in a fixed position When set product's capillary viscometer must be expandable portion 3 is immersed half. Another use a thermometer to clamp fixed, the mercury should position the ball Set close to the central point of the capillary 1 level, it is best to make a thermometer temperature scale located on the thermostat level 20mm. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 1660-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 1660-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 1660-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 1660-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 1660-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 1660-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |