Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 15041-2008 English PDF

US$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 15041-2008: High pressure short arc xenon lamps
Status: Valid

GB/T 15041: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 15041-2008419 Add to Cart 3 days High pressure short arc xenon lamps Valid
GB/T 15041-1994759 Add to Cart 5 days High pressure xenon short arc lamps Obsolete

Similar standards

GB/T 43017   GB/T 19258.1   GB 19258   GB/T 15040   GB/T 15039   GB/T 15043   

Basic data

Standard ID: GB/T 15041-2008 (GB/T15041-2008)
Description (Translated English): High pressure short arc xenon lamps
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K71
Classification of International Standard: 29.140.30
Word Count Estimation: 18,142
Date of Issue: 2008-12-30
Date of Implementation: 2009-09-01
Older Standard (superseded by this standard): GB/T 15041-1994
Quoted Standard: GB/T 191; GB/T 2423.6; GB/T 2423.8; GB/T 2423.10; GB 2797; GB/T 2829; GB/T 2900.65
Regulation (derived from): Announcement of Newly Approved National Standards No. 25 of 2008 (total 138)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the high-pressure short-arc xenon lamp (hereinafter referred to as light) model, the main dimensions, technical requirements, test methods, inspection rules, marking, packaging, transport and storage. This standard applies to 50W ~ 10000W DC high voltage short-arc xenon lamp.

GB/T 15041-2008: High pressure short arc xenon lamps

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
High pressure short arc xenon lamps ICS 29.140.30 K71 National Standards of People's Republic of China Replacing GB/T 15041-1994 High pressure xenon short arc lamp Posted 2008-12-30 2009-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Classification and Nomenclature 2 5 Technical requirements 5 6 Test methods 6 7 Inspection rules 9 8 signs, packaging, transportation and storage 10 Appendix A (normative) high-pressure xenon short arc lamp with a lamp 11 Appendix B (normative) high-pressure short-arc xenon lamp trigger 13

Foreword

This standard replaces GB/T 15041-1994 "high-pressure short-arc xenon lamp." This standard compared with GB/T 15041-1994, the main differences are as follows. --- Original standard Chapter 1 Subject Matter and Scope changed; --- Revised criteria added terms and definitions; 3.1 --- original standard lamp model name has changed; --- Original standard 3.2 in Figs. 1-1 to 1-12 and in Table 1 has been amended accordingly; --- 4.2 in Table 2 of the original standard has been amended accordingly; --- Original standard lamp in Appendix A "PSFCXd1-d2" to "SFCXd1-d2" and "PSFad1-d2" to "SFad1-d2"; --- Original Standard Appendix B, Table B1 in a no-load voltage omitted. The Standard Annexes A and B are normative appendix. The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee of electrical lighting (SAC/TC224) centralized. This standard was drafted. Changzhou Yuyu electro-optical devices Ltd., Beijing Institute of electric light. The main drafters of this standard. Xuqin Yu, Jiang Yongping, Zhao Xiurong. This standard replaces the standards previously issued as follows. --- GB/T 15041-1994. High pressure xenon short arc lamp

1 Scope

This standard specifies the high-pressure short-arc xenon lamp (hereinafter referred to as lamp) model, the main dimensions, technical requirements, test methods, inspection rules, marking Chi, packaging, transport and storage. This standard applies to 50W ~ 10000W DC high voltage xenon short-arc lamp.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 191 Packaging - Pictorial signs (GB/T 191-2008, ISO 780.1997, MOD) GB/T 2423.6 Environmental testing for electric and electronic products Part 2. Test methods - Test Eb and guidance. Bump (GB/T 2423.6-1995, idt IEC 60068-2-29. 1987) GB/T 2423.8 Environmental testing for electric and electronic products Part 2. Test methods Test Ed. Free fall (GB/T 2423.8- 1995, idt IEC 60068-2-32.1990) GB/T 2423.10 Environmental testing for electric and electronic products Part 2. Test methods - Test Fc and guidance. Vibration (sinusoidal) (GB/T 2423.10-1995, idt IEC 60068-2-6. 1982) General technical conditions GB 2797 cap GB/T 2829 Periodic inspection Sampling procedures and tables (suitable for process stability test) GB/T 2900.65 Electrotechnical terminology Lighting (GB/T 2900.65-2004, IEC 60050 (845). 1987, MOD)

3 Terms and Definitions

GB/T 2900.65, and established the following terms and definitions apply to this standard. 3.1 Lamp ignition to 10h flux value measured. 3.2 Quality Grading pilot light flux is lowered to three products limit ignition time at 70%. 3.3 That was all the arithmetic mean of the test lamp life. When the pilot light to ignite the average life expectancy of 150% should be considered the life of the lamp test is completed. Individual life of the lamp shall be not less than 50% of the average life. 3.4 Lamp cathode terminal cap from the nose to the tip of the cathode.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15041-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15041-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15041-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15041-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15041-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15041-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.