Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 13917.3-2009 English PDF

US$149.00 · In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 13917.3-2009: Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration -- Part 3: Smoke generator and smoke tablet
Status: Valid

GB/T 13917.3: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 13917.3-2009149 Add to Cart 2 days Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration -- Part 3: Smoke generator and smoke tablet Valid
GB 13917.3-1992199 Add to Cart 2 days Efficacy test methods of public health insecticides for pesticids registration. Method of laboratory efficacy test for smoke and smoke tablet Obsolete

Similar standards

GB/T 13917.10   GB/T 13917.6   GB/T 13917.4   GB/T 13917.7   GB/T 13917.8   GB/T 13917.5   

Basic data

Standard ID: GB/T 13917.3-2009 (GB/T13917.3-2009)
Description (Translated English): Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration -- Part 3: Smoke generator and smoke tablet
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: B17
Classification of International Standard: 65.100
Word Count Estimation: 5,584
Date of Issue: 2009-03-27
Date of Implementation: 2009-10-01
Older Standard (superseded by this standard): GB 13917.3-1992; GB/T 17322.3-1998
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the Efficacy test methods and evaluation criteria smoke and tobacco tablets. This section applies to tobacco smoke and pieces of health at the time of the pest mosquito pesticide registration, flies, cockroaches carried the smoke treatment efficacy test and evaluation.

GB/T 13917.3-2009: Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration -- Part 3: Smoke generator and smoke tablet


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration - Part 3.Smoke generator and smoke tablet ICS 65.100 B17 National Standards of People's Republic of China GB/T 13917.3-2009 Replace GB 13917.3-1992, GB/T 17322.3-1998 Sanitary Insecticides for Pesticide Registration Laboratory efficacy test and evaluation Part 3.Smoke agent and smoke tablets 2009-03-27 released 2009-10-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Issued by the National Standardization Administration of China

Foreword

GB/T 13917 "Indoor Efficacy Test and Evaluation of Hygienic Pesticides for Pesticide Registration" is divided into 10 parts. ---Part 1.Propellant; ---Part 2.Aerosol; ---Part 3.Smoke agent and smoke tablets; ---Part 4.Mosquito coil; ---Part 5.Electric mosquito coils; ---Part 6.Electric mosquito coil liquid; ---Part 7.Bait; ---Part 8.Powders and pens; ---Part 9.Repellent; ---Part 10.Simulate the scene. This part is Part 3 of GB/T 13917. This part replaces GB 13917.3-1992 "Indoor efficacy test methods for pesticides registered sanitary pesticides, small aerosols and smoke tablets Method for Measuring Indoor Efficacy of Pesticides" and GB/T 17322.3-1998 "Evaluation of Indoor Efficacy of Pesticide Registered Sanitary Insecticides for Small Cigarettes Fog." Compared with GB 13917.3-1992 and GB/T 17322.3-1998, the main changes of this part are as follows. ---Combine GB 13917.3-1992 and GB/T 17322.3-1998, so that the method and evaluation can be in the same standard Reflect, the application is more convenient; ---Revision of the regulations on standard test insects. adopt laboratory-raised standard test insects of sensitive strains; ---Modified and clarified the age of the tested insects; ---Modified the number of test mosquitoes; ---It is no longer required to establish a blank control test; ---Added the evaluation criteria for smoke slices; ---Standardize the way of expression in the standard; ---Added specific requirements for test results and test report compilation. This part was proposed by the Ministry of Agriculture of the People's Republic of China. This part is under the jurisdiction of the Pesticide Inspection Institute of the Ministry of Agriculture. Drafting organizations of this section. Pesticide Inspection Institute of the Ministry of Agriculture, Jilin Provincial Center for Disease Control and Prevention, Tianjin Municipal Center for Disease Control and Prevention, Guangdong Province Centers for Disease Control and Prevention. The main drafters of this section. Lin Lifeng, Wang Xiaojun, Zhang Jintong, Xin Zheng, Sun Chenxi, Wu Shixiong, Peng Bo. The previous editions of the standards replaced by this part are as follows. ---GB 13917.3-1992; ---GB/T 17322.3-1998. GB/T 13917.3-2009 Sanitary Insecticides for Pesticide Registration Laboratory efficacy test and evaluation Part 3.Smoke agent and smoke tablets

1 Scope

This part of GB/T 13917 specifies the indoor efficacy test methods and evaluation criteria for smoke agents and smoke tablets. This section is applicable to the determination and evaluation of the efficacy of smoke treatment of smoke agents and smoke chips against hygienic pests, mosquitoes, flies, and cockroaches during pesticide registration.

2 Test materials

Standard test insects of sensitive strains raised in the laboratory. 2.1 Mosquitoes Area), female adults that did not suck blood on the 3rd to 5th day after emergence. 2.2 Flies 2.3 Cockroach

3 Equipment

3.1 Square box device (Figure 1) The glass square box (B) is placed on the bracket (E). Inside the square box is a tray (A) for placing smoke agent or smoke slices. At any lower corner of one side There is a small door (C), there is a worm hole (F) above this side, which can be plugged tightly with a rubber plug, and the other side is the whole door (D). When testing, the whole Devices should be sealed GB/T 13917.3-2009 3.2 Mosquito suction tube. 3.3 Stopwatch. 3.4 Counter.

4 Test method

4.1 Test conditions Humidity (26±1)℃; Relative temperature. 60%±10%. 4.2 Test procedure A square box device (3.1) is used. Release the test insects (50 houseflies, or 50 mosquitoes, or 30 cockroaches) from the wormhole into the square box and plug it Put wormholes. According to the recommended amount of the drug to be tested, calculate the amount of drug required for the test. According to the method recommended in the instructions for use, after the application is completed within 3.1, immediately That is to close the door of the box, it should be sealed and timed. Mosquitoes and flies record the number of test insects knocked down at regular intervals. 30min, will be knocked down mosquitoes, flies or all Move cockroaches to a clean insect cage (mosquitoes and flies that have not been knocked down will not be recovered, and counted as live insects), and standard rearing should be restored (mosquitoes and flies should use 5% sugar water) Feeding with soaked cotton balls, cockroaches should be fed with mixed feed block and soaked cotton balls). Check the number of dead insects at 24h (72h for cockroaches). Test should be set Repeat three times or more. At the end of each test, the test device should be cleaned.

5 Calculation

Calculate the KT50 and virulence regression equation by repeating the test data according to the linear weighted regression method. According to formula (1), calculate the death of 24h (72h of cockroach). The death rate, the result is rounded to 2 decimal places. P=KN ×100 (1) Where. P---mortality rate, %; K---indicating the number of dead insects, the unit is only; N---indicates the total number of insects processed, the unit is only.

6 Evaluation

According to the indoor KT50, 24h (cockroach 72h) mortality rate for efficacy evaluation, the specific evaluation indicators are shown in Table 1. The efficacy results are divided into two grades. A and B. When the two indicators of KT50 and mortality are not in the same grade, they are graded according to the mortality. A product that fails to meet the B-level standard is a substandard product.

7 Results and report compilation

Perform analysis and evaluation based on the statistical results, write a formal test report, and list the original data. GB/T 13917.3-2009
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 13917.3-2009_English be delivered?

Answer: Upon your order, we will start to translate GB/T 13917.3-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 13917.3-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 13917.3-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 13917.3-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13917.3-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.