GB/T 13882-2023 English PDFUS$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 13882-2023: Determination of iodine in feeds Status: Valid GB/T 13882: Historical versions
Basic dataStandard ID: GB/T 13882-2023 (GB/T13882-2023)Description (Translated English): Determination of iodine in feeds Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: B46 Classification of International Standard: 65.120 Word Count Estimation: 10,118 Date of Issue: 2023-08-06 Date of Implementation: 2024-03-01 Older Standard (superseded by this standard): GB/T 13882-2010 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 13882-2023: Determination of iodine in feeds---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.ICS 65.120 CCSB46 National Standards of People's Republic of China Replace GB/T 13882-2010 Determination of iodine in feed Published on 2023-08-06 2024-03-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee ForewordThis document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document replaces GB/T 13882-2010 "Determination of iodine in feed - Ferric thiocyanate-nitrite catalytic kinetic method" and is consistent with Compared with GB/T 13882-2010, in addition to structural adjustments and editorial changes, the main technical changes are as follows. a) Increased the quantitative limit of the iron thiocyanate-nitrite catalytic kinetic method (see Chapter 1); b) Added inductively coupled plasma mass spectrometry (see Chapter 4); c) The preparation method of iodine standard working solution has been changed (see 5.2.10, 4.10 of the.2010 edition); d) Changed the dry ashing method (see 5.5.1, 7.1.1 of the.2010 version); e) Deleted the wet method (see 7.1.2 of the.2010 version); f) The drawing of the iodine standard working curve has been changed (see 5.5.2.1, 7.2.1 of the.2010 version); g) Changed precision (see 5.7, Chapter 9 of the.2010 edition). Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document is proposed and coordinated by the National Feed Industry Standardization Technical Committee (SAC/TC76). This document was drafted by. Guofang Wuhan Scientific Research and Design Institute Co., Ltd., Sichuan Well Testing Technology Co., Ltd., Hubei Provincial Animal Science and Technology Co., Ltd. Institute of Drug Control, Sichuan Provincial Grain Quality Monitoring Center, Chengdu Shuxing Feed Co., Ltd. The main drafters of this document. Zhang Fengping, Huang Changjun, Liu Jun, Qian Fang, Li Fang, Liu Xiaomin, Zhang Yanhong, Li Dexiang, Wang Jun, Yang Jun, Li Guiyou, Wang Boyuan, Du Yan. The previous versions of this document and the documents it replaces are as follows. ---First published as GB/T 13882-1992 in.1991, revised for the first time in.2002, and revised for the second time in.2010; ---This is the third revision. Determination of iodine in feed1 ScopeThis document describes methods for the inductively coupled plasma mass spectrometry and ferric thiocyanate-nitrite catalytic kinetic determination of iodine in feed. This document is applicable to the determination of iodine in compound feeds, concentrated feeds, concentrate supplements, additive premixed feeds and feed raw materials. The detection limit of the inductively coupled plasma mass spectrometry method in this document is 0.05 mg/kg, and the quantitation limit is 0.10 mg/kg. Ferric thiocyanate-nitrite The detection limit of the catalytic kinetic method is 0.10mg/kg, and the quantification limit is 0.20mg/kg.2 Normative reference documentsThe contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document. GB/T 6682 Specifications and test methods for water used in analytical laboratories GB/T 20195 Preparation of animal feed samples3 Terms and definitionsThere are no terms or definitions to be defined in this document. 4 Inductively coupled plasma mass spectrometry (arbitration method) 4.1 Principle The iodine in the sample is extracted with tetramethylammonium hydroxide (TMAH) solution, and measured with an inductively coupled plasma mass spectrometer. Qualification of mass number 127 (mass-to-charge ratio, m/z) is carried out based on the intensity ratio of the mass spectrum signals of iodine element and internal standard element being proportional to the concentration of iodine element. Quantitatively, determine the iodine content in the sample. 4.2 Reagents or materials Unless otherwise specified, use only high-grade pure reagents. 4.2.1 Water. GB/T 6682, Level 1. 4.2.2 Extraction solution. Measure.200mL of 25% TMAH solution, dilute with water, adjust the volume to 500mL, and mix well. 4.2.3 Dilute the solution. Pipette 5mL of 25% TMAH solution, dilute with water, adjust the volume to 500mL, and mix well. 4.2.4 Iodine standard stock solution (1mg/mL). Weigh potassium iodate (KIO3, CAS No.. 7758- 05-6, reference reagent) 0.1685g, or weigh potassium iodide (KI, CAS No.. 7681-11-0, reference reagent) dried in a silica gel desiccator for 24 hours. 0.1308g, dissolve in water, transfer to 100mL brown volumetric flask, dilute to volume with water, mix well. Store in brown bottle, 2℃~8℃ Save, valid for 3 months. Or purchase certified reference materials. 4.2.5 Iodine standard intermediate solution I (10μg/mL). Accurately transfer 1mL of iodine standard stock solution (4.2.4) into a 100mL brown volumetric flask , dilute the solution (4.2.3) to volume, and mix evenly. Ready for immediate use. 4.2.6 Iodine standard intermediate solution II (100ng/mL). Accurately transfer 1mL of iodine standard intermediate solution I (4.2.5) into 100mL brown volume ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 13882-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 13882-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 13882-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 13882-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 13882-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13882-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |