Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 13539.5-2020 English PDF

US$944.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 13539.5-2020: Low-voltage fuses - Part 5: Guidance for the application of low-voltage fuses
Status: Valid

GB/T 13539.5: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 13539.5-2020944 Add to Cart 5 days Low-voltage fuses - Part 5: Guidance for the application of low-voltage fuses Valid
GB/T 13539.5-2013RFQ ASK 3 days Low-voltage fuses -- Part 5: Guidance for the application of low-voltage fuses Obsolete
GB/T 13539.5-1999RFQ ASK 8 days Low-voltage fuses. Part 3: Supplementary requirements for fuses for use by unskilled person (fuses for mainly for household and similar apllication) Examples of standardized fuses Obsolete

Similar standards

GB 14048.1   GB 13140.1   GB 13140.4   GB/T 13539.7   GB/T 13539.6   GB/T 13539.3   

Basic data

Standard ID: GB/T 13539.5-2020 (GB/T13539.5-2020)
Description (Translated English): Low-voltage fuses - Part 5: Guidance for the application of low-voltage fuses
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K30
Classification of International Standard: 29.120.50
Word Count Estimation: 50,523
Date of Issue: 2020-11-19
Date of Implementation: 2021-06-01
Older Standard (superseded by this standard): GB/T 13539.5-2013
Regulation (derived from): National Standard Announcement No. 26 of 2020
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 13539.5-2020: Low-voltage fuses - Part 5: Guidance for the application of low-voltage fuses

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Low-voltage fuses Part 5: Application guide for low-voltage fuses) ICS 29:120:50 K30 National Standards of People's Republic of China Replace GB/T 13539:5-2013 Low voltage fuse Part 5: Application Guide for Low Voltage Fuse (IEC /T R60269-5:2014, IDT) 2020-11-19 released 2021-06-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee

Table of contents

Preface Ⅲ Introduction Ⅴ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Advantages of fuse 3 5 Structure and action of the fuse 4 6 Fuse combination appliances 9 7 Selection and marking of fuse 11 8 Wire protection 12 9 Selectivity to protect electrical appliances 15 10 Short circuit protection 20 11 Protection of power factor compensation capacitor 21 12 Transformer protection 22 13 Motor circuit protection 23 14 Circuit breaker protection in AC and DC circuits 25 15 Protection of semiconductor equipment in DC and AC circuits 26 16 Fuse in the housing 27 17 DC applications 27 18 Automatic cut-off of electrical shock protection for building installations 29 19 Photovoltaic (PV) system protection 31 20 Wind power system protection 33 Appendix A (informative appendix) Coordination between fuse and contactor/motor starter 34 References 43

Foreword

GB/T 13539 "Low Voltage Fuse" consists of the following parts: ---Part 1: Basic requirements; ---Part 2: Supplementary requirements for fuses used by full-time personnel (mainly used in industrial fuses) standardized fuse system Examples A to K; ---Part 3: Supplementary requirements for fuses used by unskilled personnel (mainly used for household and similar purposes) standardization Examples of fuse systems A to F; ---Part 4: Supplementary requirements for fuse-links for the protection of semiconductor equipment; ---Part 5: Application guide for low-voltage fuses; ---Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic systems: This part is Part 5 of GB/T 13539: This section was drafted in accordance with the rules given in GB/T 1:1-2009: This part replaces GB/T 13539:5-2013 "Low-Voltage Fuses Part 5: Application Guide for Low-Voltage Fuses", and Compared with GB/T 13539:5-2013, the main technical changes are as follows: ---Added new definitions "single breakpoint" and "double breakpoint", as well as the symbols of combination appliances with these two forms (see 3:4:1, 3:5:1, Chapter 6); ---Added the two advantages of "high level of energy efficiency" and "excellent personnel and equipment protection to prevent arc flash" (see Chapter 4); ---Added 5:3:4 "Fuse link pre-arc time-current characteristics" (see 5:3:4); ---Added 5:3:5 "fuse action at altitudes higher than:2000m" (see 5:3:5); ---The maximum working voltage value of the AC fuse link at the rated voltage of 1000V has been increased (see Table 4); --- Added Table 5 "Typical Working Voltage Ratings of DC Fuse Links" (see Chapter 7); ---Added the use categories gU, gK and gPV and the corresponding wire protection selection method, and introduced in the gG fuse selection method Enter the formula "It≤1:45IZ" and Figure 6 "Current used for fuse link selection" (see Chapter 8); ---Added the power factor compensation with a rated voltage of 1kV in Table 6 "Selection of Fuse for Power Factor Compensation Capacitor Protection" Capacitor selection parameters for 1500V fuse (see Chapter 11); ---Increase the limit requirement for the intersection current Ico in the selection method of the fuse link for motor circuit protection, that is, lower than the contactor and overload The electric withstand current of the relay contacts (see 13:4); ---Added supplementary information for part of the range of fuse-links and full range of fuse-links used to protect semiconductor equipment, including the protection of rectifiers The introduction of protective aR fuse, the action requirements of gR and gS fuse, and the addition of fuse for DC circuit semiconductor equipment The selection method (Chapter 15); ---Added an overview of DC power supplies in DC applications (see 17:1); --- Added Chapter 19 "Photovoltaic (PV) System Protection" (see Chapter 19); --- Added Chapter 20 "Wind Power System Protection" (see Chapter 20): The translation method used in this part is equivalent to the IEC /T R60269-5:2014 ``Low-Voltage Fuse Part 5: Application Guidelines for Low-Voltage Fuse south": The Chinese documents that have a consistent correspondence with the international documents cited in this section are as follows: ---GB/T 2900 (all parts) Electrical terminology [IEC 60050 (all parts)] ---GB/T 13539:1-2015 Low-voltage fuses Part 1: Basic requirements (IEC 60269-1:2009, IDT) ---GB/T 13539:2-2015 Low-voltage fuses Part 2: Supplementary requirements for fuses used by full-time personnel (mainly used Industrial fuse) Examples of standardized fuse systems A to K (IEC 60269-2:2013, IDT); ---GB/T 13539:3-2017 Low-voltage fuses Part 3: Supplementary requirements for fuses used by unskilled personnel (mainly (Fuses for household and similar purposes) Examples of standardized fuse systems A to F (IEC 60269-3:2013, IDT); ---GB/T 13539:4-2016 Low-voltage fuses Part 4: Supplementary requirements for fuse-links for the protection of semiconductor equipment (IEC 60269-4:2012, IDT); ---GB/T 13539:6-2013 Low-voltage fuses Part 6: Supplementary requirements for fuse-links for solar photovoltaic system protection (IEC 60269-6:2010, IDT); ---GB/T 14048:3-2017 Low-voltage switchgear and control equipment Part 3: Switches, isolators, disconnectors and fuses Combination appliance (IEC 60947-3:2015, IDT); ---GB/T 14048:4-2010 Low-voltage switchgear and control equipment Part 4-1: Contactors and motor starters Electric contactors and motor starters (including motor protectors) (IEC 60947-4-1:2009, MOD); ---GB/T 16895:6-2014 Low-voltage electrical installations Part 5-52: Selection of electrical equipment and installation of wiring systems (IEC 60364-5-52:2009, IDT); ---GB/T 17950-2000 Semiconductor converter Part 6: Use a fuse to protect the semiconductor converter from overcurrent Application Guidelines (IEC /T R60146-6:1992, IDT): This section has made the following editorial changes: ---Add a note in 5:3:4 to facilitate the understanding of the standard; ---Change I2 in 8:2 and Figure 6 to It, and "1:15IZ" at the right arrow in Figure 6 "Current for fuse link selection" to "1:45IZ", add a note explaining "For fuses, the agreed tripping current is called the agreed fusing current": This part was proposed by China Electrical Equipment Industry Association: This part is under the jurisdiction of the National Fuse Standardization Technical Committee (SAC/TC340): Drafting organizations of this section: Shanghai Electrical Apparatus Research Institute, Hollyland (Xiamen) Circuit Protection Technology Co:, Ltd:, Xi'an Zhongrong Electric Co:, Ltd: Co:, Ltd:, Zhejiang Chint Electric Co:, Ltd:, Wenzhou Sanshi Electric Co:, Ltd: The main drafters of this section: Li Hui, Lin Wenyuan, Shi Xiaoguang, Bian Xinbin, Huang Xuxiong: The previous versions of the standards replaced by this part are as follows: ---GB/T 13539:5-2013:

Introduction

Fuses protect all types of equipment and switchgear from overcurrent: Overcurrent may cause the following hazards: --- Thermal damage to wires or bus bars; ---Metal vaporization; ---Gas ionization; ---Arc, fire, explosion; ---Insulation damage: In addition to personal injury, shutdowns caused by overcurrent and repairs to damaged equipment may cause huge economic losses: Nowadays, the fuse is a universal overcurrent protection electrical appliance: In terms of eliminating or suppressing the effects of overcurrent, fuses provide a very Economical and effective solution: Low voltage fuse Part 5: Application Guide for Low Voltage Fuse

1 Scope

This part of GB/T 13539 is used to guide the application of low-voltage fuses: The standard describes how current-limiting fuses can be conveniently used for protection: Protect modern complex and sensitive electrical and electronic equipment: This part is applicable to the AC to the IEC 60269 series designed and manufactured Low voltage fuse of 1000V, DC to 1500V: This section provides important technical arguments and information on fuse applications:

2 Normative references

The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article Pieces: For undated references, the latest version (including all amendments) applies to this document: GB/T 16895:5-2012 Low-voltage electrical installations Part 4-43: Safety protection overcurrent protection (IEC 60364-4-43: 2008, IDT) GB/T 16895:21-2011 Low-voltage electrical installations Part 4-41: Safety protection and electric shock protection (IEC 60364-4-41: 2005, IDT) GB /Z 25842:1-2010 Low-voltage switchgear and control equipment overcurrent protective electrical appliances-Part 1: Application of short-circuit rating (IEC /T R61912-1:2007, IDT) IEC 60050 (all parts) International Electrotechnical Vocabulary (InternationalElectrotechnicalVocabulary) IEC /T R60146-6 Semiconductor converter Part 6: Use of fuses to protect semiconductor converters against overcurrent applications Then (Semiconductorconvertors-Part 6: Application guide for the protection of semiconductor convertorsagainstovercurrentbyfuses) IEC 60269 (all parts) Low-voltage fuses IEC 60269-1:2006 Low-voltage fuses-Part 1: Basic requirements (Low-voltagefuses-Part 1: Generalre- quirements) IEC 60269-2 Low-voltage fuses Part 2: Supplementary requirements for fuses used by full-time personnel (mainly used for industrial fuses) ) Standardized fuse system examples A to K (Low-voltagefuses-Part 2:Supplementaryrequirementsfor fusesforusebyauthorizedpersons(fusesmainlyforindustrialapplication)-Examplesofstandardized systemsoffusesAtoK] IEC 60269-3 Low-voltage fuses Part 3: Supplementary requirements for fuses used by unskilled personnel (mainly used for household and Similar purpose fuses) Examples of standardized fuse systems A to F (Low-voltagefuses-Part 3:Supplementaryrequire- mentsforfusesforusebyunskiledpersons(fusesmainlyforhouseholdorsimilarapplications)-Ex- amplesofstandardizedsystemsoffusesAtoF] IEC 60269-4:2009 Low-voltage fuses Part 4: Supplementary requirements for fuse-links for the protection of semiconductor equipment (Low-voltage fuses-Part 4:Supplementaryrequirementsforfuse-linksfortheprotectionofsemiconductordevices) IEC 60269-6 Low-voltage fuses Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic systems (Low-voltage fuses-Part 6:Supplementaryrequirementsforfuse-linksfortheprotectionofsolarphotovoltaicener- gysystems) IEC 60364-5-52 Low-voltage electrical installations Part 5-52: Selection and installation of electrical equipment wiring system (Low-voltage
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 13539.5-2020_English be delivered?

Answer: Upon your order, we will start to translate GB/T 13539.5-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 13539.5-2020_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 13539.5-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 13539.5-2020?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13539.5-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.