GB/T 11844-2015 English PDFUS$239.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 11844-2015: Determination of fluorine and chlorine in uranium dioxide powder and pellets -- Pyrohydrolysis ion-selective electrode method Status: Valid GB/T 11844: Historical versions
Basic dataStandard ID: GB/T 11844-2015 (GB/T11844-2015)Description (Translated English): Determination of fluorine and chlorine in uranium dioxide powder and pellets -- Pyrohydrolysis ion-selective electrode method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F46 Classification of International Standard: 27.120.30 Word Count Estimation: 11,170 Date of Issue: 2015-07-03 Date of Implementation: 2016-02-01 Older Standard (superseded by this standard): GB/T 11844-1989; GB/T 13369-1992 Adopted Standard: ISO 22875-2008, MOD Regulation (derived from): National Standard Announcement 2015 No.22 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies the determination of uranium dioxide powders and pellets by fluorine, chlorine feed method, reagents, instruments and equipment, sample analysis step, the results of calculation and precision of the method. This Standard applies dioxide powder and fluorine, chlorine measurement of uranium pellets, when said sample in the range of 0.5 g ~ 5.0g, fluorine measurement range of 1 ��g/g ~ 400 ��g/g, chlorine measurement range of 2 ��g/g ~ 200 ��g/g. Present in the absorbing solution impurity ions Al (3+) is not greater than 16 ��g, Ca (2+) is not greater than 10��g, Fe (3+) is not greater than 10 ��g, Mg (2+) at not more than 22 ��g of fluorine Determination of no effect. GB/T 11844-2015: Determination of fluorine and chlorine in uranium dioxide powder and pellets -- Pyrohydrolysis ion-selective electrode method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of fluorine and chlorine in uranium dioxide powder and pellets. Pyrohydrolysis ion-selective electrode method ICS 27.120.30 F46 National Standards of People's Republic of China Replacing GB 11844-1989, GB/T 13369-1992 Determination of uranium dioxide powder and pellets by fluorine, chlorine High temperature hydrolysis - ion selective electrode method (ISO 22875.2008, Nuclearenergy-Determinationofchlorineand fluorineinuraniumdioxidepowderandsinteredpelets, MOD) Issued on. 2015-07-03 2016-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB 11844-1989 "uranium dioxide powder and pellets - Determination of fluorine high temperature hydrolysis - ion selective electrode method" and GB/T 13369-1992 "uranium dioxide powder and pellets - Determination of chlorine in high temperature hydrolysis - ion selective electrode method" and GB 11844- 1989 and GB/T 13369-1992, compared the main technical changes are as follows. --- Modify the sample size and measurement range; --- Modify the standard curve drawing content; --- Modified high temperature hydrolysis process parameters; --- Modify the GB 11844-1989 and GB/T 13369-1992 precision. This standard uses redrafted Law Amendment uses ISO 22875.2008 "Nuclear testing uranium dioxide powder and sintered pellets of CFCs set". This standard and ISO 22875.2008, compared with more adjustment in the structure, listed in Appendix A of this standard and ISO 22875.2008 The reg number control list. This standard and ISO 22875.2008 technical differences exist compared to the terms of these differences has been involved through its outer margin bits Opposing vertical single line (︱) were marked, Appendix B gives a list of corresponding technical differences and their causes. This standard and ISO 22875.2008 compared also made the following editorial changes. --- Change in name; --- Increase the informative Appendix C. The standard proposed by China National Nuclear Corporation. This standard by the National Standardization Technical Committee on Nuclear Energy (SAC/TC58) centralized. This standard was drafted. China Jianzhong Nuclear Fuel Limited. The main drafters of this standard. Song Lijuan, Xu Jianping, Zhang Shihong, summer rainbow. This standard replaces the standards previously issued as follows. --- GB 11844-1989; --- GB/T 13369-1992. Determination of uranium dioxide powder and pellets by fluorine, chlorine High temperature hydrolysis - ion selective electrode method1 ScopeThis standard specifies the determination of uranium dioxide powders and pellets by fluorine, chlorine feed method, reagents, instruments and equipment, sample analysis step junction If the calculation and precision of the method. This standard applies dioxide powder and fluorine, chlorine measured uranium pellets that when a sample in the range of 0.5g ~ 5.0g, the measurement range of the fluorine 1μg/g ~ 400μg/g, chlorine measurement range 2μg/g ~ 200μg/g. The absorbing solution in the presence of impurity ions Al3 not more than 16μg, Ca2 no more than 10μg, Fe3 not more than 10μg, when Mg2 not more than 22μg, does not affect the determination of fluoride.2 Method summarySample in a quartz reactor tube 900 ℃ ~ 1000 ℃, the pass into the air stream containing water vapor at high temperature hydrolysis, fluorine, chlorine, fluorine, respectively Hydrogen, hydrogen chloride forms evaporate and is absorbing buffer solution, ion selective electrode with fluoride, chloride ion selective electrode.3 ReagentsUnless otherwise indicated, all using the national standard or professional standard, superior grade pure reagents, analysis of water should comply with the electrical conductivity (25 ℃) is not greater than 0.10mS/m. 3.1 buffer solution Weigh 0.50g of potassium acetate (CH3COOK) (AR) in 100mL beaker, dissolved in water, glacial acetic acid was added 0.25mL (CH3COOH, the density of 1.05g/cm3), in its entirety was transferred to a 1L volumetric flask and dilute to the mark, shake, stored in polyethylene bottles Standby. 3.2 fluorine standard solutions, 1000μg/mL Weigh 2.2101g by sodium fluoride (NaF) drying 2h under 105 ℃ ~ 110 ℃, dissolved in a little water and transferred to a 1L volumetric flask Diluted with water to the mark, shake, stored in a polyethylene bottle aside. Or the use of certified reference materials. 3.3 fluorine standard solutions, 50μg/mL (3.2) standard solution was diluted with a fluorine. 3.4 chlorine standard solution, 1000μg/mL Weigh 1.6485g burning after 400 ℃ ~ 450 ℃ to constant weight of sodium chloride (NaCl), dissolved in a little water and transferred to a 1L volumetric flask Diluted with water to the mark, shake, stored in a polyethylene bottle aside. Or the use of certified reference materials. 3.5 chlorine standard solution, 50μg/mL (3.4) with diluted chlorine standard solution. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 11844-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 11844-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 11844-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 11844-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 11844-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11844-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |