Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 11007-2008 English PDF

US$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 11007-2008: Test method of electrolytic conductivity analyzers
Status: Valid

GB/T 11007: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 11007-2008259 Add to Cart 3 days Test method of electrolytic conductivity analyzers Valid
GB/T 11007-1989439 Add to Cart 4 days Test method of electric conductivity analyzers Obsolete

Similar standards

GB/T 12519   GB/T 25929   GB/T 25930   GB/T 17365   GB/T 21638   GB/T 15074   

Basic data

Standard ID: GB/T 11007-2008 (GB/T11007-2008)
Description (Translated English): Test method of electrolytic conductivity analyzers
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: N53
Classification of International Standard: 71.040.01
Word Count Estimation: 11,153
Date of Issue: 2008-06-30
Date of Implementation: 2009-01-01
Older Standard (superseded by this standard): GB/T 11007-1989
Quoted Standard: GB/T 11606; JB/T 8277; JB/T 8278
Regulation (derived from): Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the conductivity meter pilot projects and methods. This standard applies to the determination of the conductivity of the electrolyte solution instruments, including sensors and electronic units.

GB/T 11007-2008: Test method of electrolytic conductivity analyzers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method of electrolytic conductivity analyzers ICS 71.040.01 N53 National Standards of People's Republic of China Replacing GB/T 11007-1989 Conductivity Meter Test Method Posted 2008-06-30 2009-01-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard replaces GB/T 11007-1989 "Conductivity Meter Test Method." This standard is the technical content and the main difference between the original criteria are as follows. --- Reference standards are using the latest version; --- Table 1 Reference conditions according to GB/T 11606 modified. Wherein. the ambient temperature by the "(25 ± 2) ℃" to "(23 ± 2) ℃"; Atmospheric pressure from "Pending" to "(86 ~ 106) kPa"; increase Table 1 Note 1, 2; --- According conductivity meter display case, original standard conductance (symbol G) were changed to electric conductivity (symbol κ); --- Figure 1, the original standard temperature increase measured with analog devices (resistance box); --- Original standard "basic error" was changed to "inherent error"; --- According to the current display of conductivity meter, conductivity measurement range to make the appropriate changes, see Table 3; --- Cleaned before testing the conductivity cell from the conductivity of deionized water was "not larger than 0.2 × 10-6S · cm-1" to "no more than 1 × 10-6S · cm-1 "; --- Table 3, the original standard conductivity range of the standard solution does not have the number corresponding relationship, now changed to two tables (Tables 3 and 4); --- 5.3.2 basic error in the original standard test method for supporting an increase in the Standard Test Method for unknown cell constant and temperature increases error; --- Original standard 5.3.9 Temperature compensation error from the operability has been modified; instead the temperature coefficient of the temperature coefficient compensation error Indication Error number representation; --- Original standard 5.3.10 constant compensator error indication error switch cell constant representation; --- Cancel the original standard safety test methods damp pretreatment; --- Cancel the original standard tables 5.4.3 dielectric strength test 4. The standard proposed by China Machinery Industry Federation. The standard measurement and control of the instruments Standardization Technical Committee Technical Committee under the jurisdiction of the national industrial processes. This standard is drafted by. Shanghai Precision & Scientific Instrument Co., Ltd. The main drafters of this standard. Wang Qiaomei, Gu Minjie, Kim Chun law. This standard superseded standard previously issued as follows. --- GB/T 11007-1989. Conductivity Meter Test Method

1 Scope

This standard specifies the conductivity meter test items and methods. This standard applies to the determination of the electrolyte solution conductivity instrument, including sensors and an electronic unit (hereinafter referred to as the instrument).

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 11606 analytical instruments environmental test methods JB/T 8277 conductivity meter with calibration solution preparation JB/T 8278 Conductivity Meter test solution of sodium chloride solution preparation method

3 influence quantity

3.1 Reference conditions Reference conditions are shown in Table 1. Table 1 Reference conditions No. influence quantity reference value or tolerance range Unit Unit An ambient temperature of 23 ℃ ± 2 ℃ 2 ~ 75% relative humidity 45 - - 3 atmospheric pressure 86 ~ 106 kPa - - 4 air flow 0 ~ 0.2 m/s - - 5 no direct exposure to solar radiation - - - 6 harmful gases is negligible - - - 7 dust negligible - - - 8 AC supply voltage 220 V ± 2.2 V 9 AC power frequency 50 Hz ± 0.5 Hz 10 AC power supply distortion β = 0 - β = 0.05 - 11 external electromagnetic interference should be avoided - - - 12 mechanical vibration is negligible - - - 13 job positions by the product specification - ± 1 ° 14 ventilated - - - Note 1. The relative humidity, atmospheric pressure, any value in this range. 3.2 rated operating range Rated operating range shown in Table 2.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 11007-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 11007-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 11007-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 11007-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 11007-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11007-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.