Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 10256-2013 English PDF

US$329.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 10256-2013: Radioactivity meter
Status: Valid

GB/T 10256: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 10256-2013329 Add to Cart 3 days Radioactivity meter Valid
GB/T 10256-1997639 Add to Cart 5 days Radioactivity meter Obsolete
GB/T 10256-1988RFQ ASK 3 days Activity meter Obsolete

Similar standards

GB/T 13286   NB/T 20318   GB/T 24247   GB/T 10259   GB/T 10255   GB/T 15476   

Basic data

Standard ID: GB/T 10256-2013 (GB/T10256-2013)
Description (Translated English): Radioactivity meter
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: F87
Classification of International Standard: 17.240
Word Count Estimation: 14,162
Older Standard (superseded by this standard): GB/T 10256-1997
Quoted Standard: GB 4075-2009; GB/T 8993-1998; GB/T 10257-2001; GB 11806-2004; GB/T 19661.1-2005; EJ/T 1059-1998; JJG 377-1998
Regulation (derived from): National Standards Bulletin 2013 No. 2
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the radioactive Activity Meter (hereinafter referred to as Activity Meter) technical requirements, test methods, inspection rules, marking, packaging, transportation, storage, accompanying documents and daily inspection requirement

GB/T 10256-2013: Radioactivity meter

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Radioactivity meter ICS 17.240 F87 National Standards of People's Republic of China Replacing GB/T 10256-1997 Radioactivity meter Issued on. 2013-02-07 2013-07-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 10256-1997 "radioactivity meter" and GB/T 10256-1997 compared to the main changes are as follows. --- Normative references have been deleted standard abolished, updated version of the standard reference, an increase of EJ/T 1059 and other lead Standard; --- Rated conditions of use in increasing the DC power requirements (see 5.1); --- Removed 113mIn other nuclei, increased 18F, 11C, 13N and other nuclides (see 4.2); --- Revised requirements relative intrinsic error performance requirements (see 4.2); --- Affect the amount of change in Table 3, Table 4 and 4.6 into one table a comprehensive description of the changes affect the amount requested, the instrument temperature, humidity According to the internal temperature of the test requirements GB/T 8993-1998 standard laboratory equipment in the humidity has been revised (see 4.3); --- Specifies the sources and methods of measurement based on the upper limit of the evaluation activity meter measuring range (see 5.8); --- Provides DC power supply activity meter electrical safety requirements (see 4.4.1); --- Specifies the energy range used for the measurement of the amount of radionuclides requirements (see 5.4); --- Source oversight requirements moved to Chapter 7 (see 7.6); --- Delivery inspection inspection rules in the measurement limit modify elected to do, others do not check the original entries to choose to do the project (see Table 6). The standard proposed by China National Nuclear Corporation. This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) centralized. This standard was drafted. nuclear (Beijing) Nuclear Instrument Factory. The main drafters of this standard. Yangbin Hua, Yang Suhua, Zhu Zhihong, Ning Xiaoyong. Radioactivity meter

1 Scope

This standard specifies the radioactivity meter (hereinafter referred to as activity meter) technical requirements, test methods, inspection rules, marking, packaging, transportation, Storage, requires accompanying documents and routine inspections. This standard applies to the well-type ionization chamber of the pneumatic detectors activity meter.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 4075-2009 Sealed radioactive sources - General requirements and classification GB/T 8993-1998 nuclear instruments - Environmental conditions and testing procedures GB/T 10257-2001 nuclear instruments and nuclear radiation detectors Quality inspection rule GB 11806-2004 safe transport of radioactive materials regulations GB/T 19661.1-2005 nuclear instrumentation General requirements for safety EJ/T 1059-1998 nuclear instrumentation packaging General technical requirements JJG377-1998 radioactivity meter

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 For measuring the activity of radioactive sources and equipped with a device indicating or recording instruments. 3.2 Well type ionization chamber wel-typeionizationchamber Within for nearly 4π solid angle range measurement radiator radioactivity ionization chamber. In the center of the ionization chamber has a cylindrical Well, the source under test is placed in the well. 4. Technical Requirements 4.1 appearance and mechanical properties Appearance and mechanical properties of the activity meter should meet the following requirements. a) activity meter of the surface coating should be smooth and firm, there should be no rust, cracks, spalling and other defects; b) writing on the nameplate and the panel should be clear; c) control mechanism should be flexible, reliable fastening parts should be no loose. 4.2 Performance Characteristics Activity meter according to the performance characteristics are divided into grade Ⅰ and Ⅱ grade, performance characteristics at reference conditions shown in Table 1.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 10256-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 10256-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 10256-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 10256-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 10256-2013?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10256-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.