GB/T 10209.4-2010 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10209.4-2010: Determination of monoammonium phosphate and diammonium phosphate -- Part 4: Particle size Status: Valid GB/T 10209.4: Historical versions
Basic dataStandard ID: GB/T 10209.4-2010 (GB/T10209.4-2010)Description (Translated English): Determination of monoammonium phosphate and diammonium phosphate -- Part 4: Particle size Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G20 Classification of International Standard: 65.080 Word Count Estimation: 7,798 Date of Issue: 2010-06-30 Date of Implementation: 2011-01-01 Older Standard (superseded by this standard): GB/T 10209.4-2001 Quoted Standard: GB/T 6003.1-1997 Regulation (derived from): National Standard Approval Announcement 2010 No.2 (Total No.157) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the determination of the title granular monoammonium sieving, DAP granularity. DAP particle size determination, This section applies to a variety of craft production along granular monoammonium phosphate. GB/T 10209.4-2010: Determination of monoammonium phosphate and diammonium phosphate -- Part 4: Particle size---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of monoammonium phosphate and diammonium phoshpate Part 4. Particle size ICS 65.080 G20 National Standards of People's Republic of China Replacing GB/T 10209.4-2001 MAP, DAP measurement method Part 4. size Part 4. Particlesize Issued on. 2010-06-30 2011-01-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 10209 "monoammonium phosphate, diammonium phosphate determination method" is divided into four parts. --- Part 1. total nitrogen content; --- Part 2. phosphorus content; --- Part 3. Water; --- Part 4. granularity. This section is GB/T Part of 410,209. This Part replaces GB/T 10209.4-2001 "monoammonium phosphate, diammonium phosphate particle size determination." The main difference between this version and the previous version is. according to the new requirements of the standard format has been rewritten. This part is proposed by the China Petroleum and Chemical Industry Association. This part of the National Standardization Technical Committee and soil conditioners Fertilizers (SAC/TC105) centralized. This section drafted by. National Fertilizer Quality Supervision and Inspection Center (Shanghai), Liuguo Chemical Corporation. The main drafters of this section. Zhou Yongming, yellow front, business according to Cong Mu Yongfeng, Yang. This section first published in 1988 (GB/T 10211-1988), 2001 on the first amendment. MAP, DAP measurement method Part 4. size1 ScopeThis section provides GB/T 10209.4 measured by sieving granular monoammonium phosphate, diammonium phosphate particle size. This section applies to a variety of granular MAP production process, diammonium phosphate particle size measurement.2 Normative referencesThe following documents contain provisions which, through reference GB/T 10209 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 6003.1-1997 woven wire mesh test sieve (eqv ISO 3310-1.1990) Principle 3 By sieving granular monoammonium phosphate, diammonium phosphate into different particle diameters, weighing, calculate the mass fraction.4 Instrument4.1 laboratory equipment generally; 4.2 Balance. a sense of the amount of 0.5g; 4.3 test sieve (GB/T 6003.1-1997R40/3 series). a pore diameter of 1.00mm, 4.00mm sieve set, with cover and sieve Chassis; 4.4 sieve shaker.5 StepsBy 1.00mm and 4.00mm sieve apertures sequentially folded by the first, laboratory sample weighed about 200g, accurate to 0.5g, Pore \u200b\u200bsize is placed on the 4.00mm sieve, sieve cover lid placed on the sieve shaker, clamping, vibration 5min, the chassis and 4.00mm aperture sieve Weighing on the sample, caught in the meshes of the particles does not pass through the sieve meter. NOTE. If there is no vibration sieve, vibrating sieve can be used manually, but using a sieve shaker arbitration.6 expression analysisSize (w), to a particle size 1.00mm ~ 4.00mm particulate quality of the sample mass fraction, expressed in%, according to equation (1) Calculated. w = m1-m2m1 × 100 (1) Where. Value m1 --- sample mass, in grams (g); m2 --- 4.00mm aperture sieve and sample the quality of the chassis and, in grams (g). Calculation result to one decimal place. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10209.4-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 10209.4-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 10209.4-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10209.4-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 10209.4-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10209.4-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |