GB 6220-2023 English PDFUS$609.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 6220-2023: Respiratory protection - Air line respirator Status: Valid GB 6220: Historical versions
Basic dataStandard ID: GB 6220-2023 (GB6220-2023)Description (Translated English): Respiratory protection - Air line respirator Sector / Industry: National Standard Classification of Chinese Standard: C73 Classification of International Standard: 13.340.30 Word Count Estimation: 30,355 Date of Issue: 2023-12-28 Date of Implementation: 2025-01-01 Older Standard (superseded by this standard): GB 6220-2009 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB 6220-2023: Respiratory protection - Air line respirator---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.ICS 13:340:30 CCSC73 National Standards of People's Republic of China Replace GB 6220-2009 Respiratory protection long tube respirator Published on 2023-12-28 Implemented on 2025-01-01 State Administration for Market Regulation Released by the National Standardization Administration Committee Table of contentsPreface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Product classification and composition 4 5 Technical requirements 4 5:1 Materials 4 5:2 Structure 4 5:3 Tight-fitting mask 5 5:4 Open masks and air supply hoods 5 5:5 Additional protective functions 6 5:6 Total Leakage Rate (TIL) 6 5:7 Carbon dioxide content in inhaled gas 6 5:8 Respiratory resistance 6 5:9 Breathing tube 7 5:10 Air supply pipe 7 5:11 Connection Strength 7 5:12 Manufacturer’s Minimum Design Air Delivery Volume (MMDF) 8 5:13 Flow regulating valve 8 5:14 High and low temperature adaptability 8 5:15 Flammability of components 8 5:16 Air supply device 8 5:17 Pulmonary valve 9 5:18 Noise 9 5:19 Mobile compressed air supply system 9 5:20 Conversion device 10 5:21 Cleaning and disinfection10 5:22 Practical performance10 6 Test Method 10 6:1 Test sample 10 6:2 Test environmental conditions 11 6:3 Appearance inspection 11 6:4 Preprocessing 11 6:5 Total Leakage Rate (TIL) 11 6:6 Carbon dioxide content in inhaled gas13 6:7 Respiratory resistance13 6:8 Breathing tube 14 6:9 Air supply pipe 15 6:10 Air supply pipe pressure resistance18 6:11 Air supply volume 18 6:12 Flammability21 6:13 Air supply device 22 6:14 Noise 22 6:15 Strength of metallic and non-metallic high-voltage components23 6:16 Air consumption of low pressure warning device 23 6:17 Practical performance 23 7 logo 23 7:1 General requirements 23 7:2 Identification of air supply pipes 23 8 Information provided by the manufacturer24 Reference 25ForewordThis document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting: This document replaces GB 6220-2009 "Respiratory Protection Long Tube Respirators": Compared with GB 6220-2009, except for structural adjustments and editing In addition to sexual changes, the main technical changes are as follows: a) Changes in terms and definitions (see Chapter 3, Chapter 3 of the:2009 edition); b) Added technical requirements for open masks and air supply hoods (see 5:4); c) Added additional protective functions (see 5:5); d) Changed the technical requirements for total leakage rate (see 5:6, 5:2:2 of the:2009 edition); e) Changed the technical requirements for respiratory resistance (see 5:8, 5:2:3 of the:2009 edition); f) Added technical requirements for breathing tubes (see 5:9); g) Added technical requirements for air supply pipes (see 5:10); h) The manufacturer’s designed minimum air supply volume has been changed (see 5:12, 5:2:1 of the:2009 version); i) Added technical requirements for the flammability of components (see 5:15); j) Added technical requirements for cleaning and disinfection (see 5:21); k) Added technical requirements for practical performance (see 5:22); l) Added the test method for total leakage rate (see 6:5); m) The test method of respiratory resistance has been changed (see 6:7, 6:4 of the:2009 edition); n) Added testing methods for breathing tubes (see 6:8); o) Added test method for air supply pipe (see 6:9); p) The test method of air supply volume has been changed (see 6:11, 6:8 of the:2009 edition); q) Added test methods for component flammability (see 6:12); r) Added noise test method (see 6:14); s) Added test methods for the strength of metallic and non-metallic high-voltage components (see 6:15); t) Added practical performance test methods (see 6:17); u) Added information provided by the manufacturer (see Chapter 8): Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents: This document is proposed and managed by the Ministry of Emergency Management of the People's Republic of China: The previous versions of this document and the documents it replaces are as follows: ---First released in 1986 as GB 6220-1986, GB 6221-1986; ---The first revision was GB 6220-2009 in:2009; ---This is the second revision: Respiratory protection long tube respirator1 ScopeThis document gives the product classification and composition of long tube respirators, specifies the technical requirements and markings of long tube respirators, and describes the testing method: This document is applicable to industrial workplaces where long-tube respirators are required: This document does not apply to firefighting workplaces:2 Normative reference documentsThe contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document: GB/T 1226 General pressure gauge GB 2626-2019 Respiratory protection self-priming filter-type anti-particulate respirator GB 2811-2019 Head protection helmet GB 2890-2022 Respiratory protection self-priming filter gas mask GB/T 3609:1-2008 Occupational eye and face protection Welding protection Part 1: Welding protective equipment GB/T 3609:2-2009 Occupational eye and face protection Welding protection Part 2: Automatically darkening welding filters GB/T 3785:1 Electroacoustic sound level meter Part 1: Specifications GB/T 5099:1 Seamless steel gas cylinders Part 1: Steel cylinders with a tensile strength of less than 1100MPa after quenching and tempering GB/T 5703 Anthropometric basic items for technical design GB/T 9572 Determination of resistance and conductivity of rubber and plastic hoses and hose assemblies GB/T 12903 Personal protective equipment terminology GB 14866-2023 General technical specifications for eye and face protective equipment GB/T 16556-2007 Self-contained open circuit compressed air breathing apparatus GB/T 18664 Selection, use and maintenance of respiratory protective equipment GB/T 23465 Practical performance evaluation of respiratory protective equipment GB/T 28053 Aluminum alloy liner carbon fiber fully wrapped gas cylinder GB/T 31975 Technical requirements for compressed air for respiratory protection GB/T 32166:2-2015 Personal protective equipment Eye and face protection Occupational eye and face protection Part 2: Measurement methods GB/T 34527 Technical specifications for cylinder valves for air respirators3 Terms and definitionsThe terms and definitions defined in GB/T 12903 and the following apply to this document: 3:1 long tube respirator airlinerespirator Protective equipment that isolates the wearer's respiratory organs from the surrounding air and obtains breathable air through a long tube: ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 6220-2023_English be delivered?Answer: Upon your order, we will start to translate GB 6220-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 6220-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB 6220-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB 6220-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 6220-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |