GB 50370-2005 PDF EnglishUS$85.00 · In stock · Download in 9 seconds
GB 50370-2005: Code for design of gas fire extinguishing systems Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
GB 50370-2005: Code for design of gas fire extinguishing systems---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB50370-2005NATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA Code for Design of Gas Fire Extinguishing Systems Date of issuing. March 2, 2006 Date of enforcement. May 1, 2006 Jointly issued by. Ministry of Construction of the People's Republic of China General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China PrefaceAccording to the requirement of "Notice on Promulgation of '"Plan for Preparation and Modification of National Standards for Project Construction 2001 ~2002" Document JB [2002] No.26 the \;linistry of Construction of PRC. this Standard is prepared by Tianjin Fire Research Institute of .V1inistry of Public Security, jointly by other relevant units. During the preparation. the editorial group carried out thorough and in-depth investigation and research. carefully summarized achievements of scientific research in the researching. production. design and application and the practical experience of the engineering about the gas fire extinguishing systems in our country, referred to the relevant international standards and the ones of developed countries such as America. Japan and Germany, and employed the fundamental experiments and the experimental research on engineering applications. After extensive opinions have been obtained from departments and units of design, scientific research. manufacturing, construction, universities and colleges, and supervision on fire fighting, the Standard is finalized by relevant depaiiments, under the review of expe1is. This Standard consists of 6 chapters and 7 appendixes, in which the main contents are. general, terms and symbols, design requirements, system components. operation and controL and safety requirements. Those clauses in block are mandatory clauses, which must be forced strictly. The Ministry of Construction will be responsible for the management and explanation on the mandatory clauses. The Ministry of Public Security will be responsible for the specific management. Tianjin Fire Research Institute of Ministry of Public Security will be responsible for the explanation on the detailed technical contents. During the implementation. the users of this Standard are kindly required to summarize experience and collect materials, and send any suggestion or comment in this regard to Tianjin Fire Research Institute of Ministry of Public Security (Address. 110 South Road of Weijin of Nankai District Tianjin. Post Code. 300381) at any time for reference in future revision. Chief editorial units. paiiicipating editorial units and major drafters of this Standard. Chief editorial units. Tianjin Fire Research Institute of Ministry of Public Security Participating editorial units. National Quality Supervision & Testing Center on Fixed Fire Extinguishing Systems and Fire-Retarding Components Beijing Urban Engineering Design & Research Institute China Academy of Railway Sciences Shenzhen International Safety Technology Co., Ltd. China Mobile Communications Corporation Shanxi General Fire Brigade of Public Security Fire Administration of Shenzhen Public Security Bureau Guangdong Shengjie Fire Protection Group Zhejiang Lantian Environmental Protection Hi-Tech Co., Ltd. Hangzhou New Epoch Fire Protection Science and Technology Co., Ltd. Xi'an Jianrui Chemical Industry Co., Ltd.Table of ContentsGeneral ... J 7 Terms and Symbols ... 2 2.1 Terms ... 2 2.2 Symbols ... 3 3 De.s ign Require1r·1e.nts ... 6 3. ! Ge neral Provis ions ... 6 3.2 System Set-up ... 7 3.3 Extinguishing Systen1s of Hepta-Fluoropropane ... 8 3.4 IG541 Mixed Gas Fire-Extinguishing System ... 13 3.5 Pre-engineered Syste m of Condensed Fire-Extinguishing Aerosol... 16 System Components ... 18 4. 1 General Provi sions ... 18 4.2 Special Requirements on Components of Hepta-Fluoropropane Extinguishing Systems ... 19 4.3 Special Requirements on Components of IG54 l Mixed-Gas Extinguishing Systems .. 20 4.4 Special Requirements on Components of Pre-Engineered Systems of Condensed Fire-Extinguishing Aerosol... 20 5 Operations and Contro ls ... 21 6 Safety Requirements ... 22 Appendix A Concentrations of Extinguishing and Inerting ... 23 Appendix B Modified Coefficients of Height above Sea level ... 25 Appendix C Jetting Rate of Equivalent Orifice Unit Area about Nozzles of Hepta-Fluoropropane Extinguishing System ... 26 Appendix D Nozzle Specifications and Equivalent Orifice Area ... 28 Appendix E Coefficients of Both Pressure and Density on Pipe Channels of IG54 l Mixed Gas Extinguishing Systems ... 29 Appendix F Jetting Rate of Equivalent Orifice Unit Area about Nozzles of IG541 Mixed Gas Extinguishing System ... 3 1 Appendix G Concentrations of No-Toxicity Response (NOAEL) and with Toxicity Response (LOAEL) and Technological Properties of Fire Agent... 33 Word Diction of the Code ... 34 1 General 1.0.1 This Standard has been \\ orked out for the purpose of designing gas fire extinguishing systems reasonably, reducing fire damage. and protecting the safety of human body and properties. 1.0.2 This code applies to the design on total flooding extinguishing of hepta-tluorupropane, mixed gas 1G54 l. and condensed fire extinguishing aerosol. 1.0.3 Design of gas fire extinguishing systems shall comply with the national guiding principles and policies, and be safe, technologically advanced. economic and reasonable . 1.0.4 Products and components of the system applied according to the design must be m accordance with national standards and regulations. 1.0.5 Besides complying \\ith this standard, the design of gas fire extinguishing systems shall also comply with other relevant current national standards. 2 Terms and Symbols 2. 1 Terms 2.1. l Protected area The restricted enclosure space sati sfying the demands of total f1ood extinguish ing system 2.1.2 Tota! flooding extinguish ing system The fire extinguishing system in \\'h ich dur ing the regulated time the fire agent with the designed standard use level is ble\\ towa1·cls the protected area w hi ch is filled with the agent evenly. 2.1.3 Piping extinguishing system The fire extinguishing system in which the fire agent transported from storage device to blowing components via main and branch pipes is blew based on the design and calculation according to cetta in appl ication conditions. 2.1.4 Pre-engineered system The fire extinguishing system in which the storage device and blowing components of fire agent are pre-designed and assembled to be a whole set with functions of gang control 2.1.5 Combined distribution systems The fire extinguishing system in which a set of storage devices of gas extinguishing agent is applied through the selection distribution of pipe network to protect two or more than two protected areas. 2.1.6 Flame extinguishing concentration The mi nimum volume percent of the gas extinguishing agent in the air needed fo r putting out ce1tain fire under circumstances of l 0 1 kPa air pressure and regulated temperature. 2.1. 7 Flame extinguishing density The mass of solid condensed-fire -extinguishing-aerosol generate needed for putting out certain fire in the unit volume, under circumstances of 101 kPa air pressure and regu lated temperature. 2.1.8 Inerting concentration The minimum volume percent of the gas extinguishing agent in the air needed fo r restraining the occurrence of burning rising from the f1ammable and combustible gas or liquid steam with any concentration in the air, under circumstances of l 01 kPa air pressure and regulated temperature, in case of the fire source. 2.1.9 Soaking time The time that the designed concentration of fire agent is maintained in the protected areas to put out the fire completely 2.1.10 Pressure re lief opening The opening where the pressure is released to prevent the internal pressure of protected areas fro m ex~eeding the allowable pressure, in case of the blowing of fire agent. 2... ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB 50370-2005 be delivered?Answer: The full copy PDF of English version of GB 50370-2005 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB 50370-2005_English with my colleagues?Answer: Yes. The purchased PDF of GB 50370-2005_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 50370-2005 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB 50370-2005?A step-by-step guide to download PDF of GB 50370-2005_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB 50370-2005". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |