GB 4234.2-2024 English PDFUS$199.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 4234.2-2024: Implants for surgery - Metallic materials - Part 2: Unalloyed titanium Status: Valid
Basic dataStandard ID: GB 4234.2-2024 (GB4234.2-2024)Description (Translated English): Implants for surgery - Metallic materials - Part 2: Unalloyed titanium Sector / Industry: National Standard Classification of Chinese Standard: C35 Classification of International Standard: 11.040.40 Word Count Estimation: 10,155 Date of Issue: 2024-10-28 Date of Implementation: 2026-11-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB 4234.2-2024: Implants for surgery - Metallic materials - Part 2: Unalloyed titanium---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.ICS 11.040.40 CCSC35 National Standard of the People's Republic of China Surgical implant metal materials Part 2.Pure titanium Implantsforsurgery-Metalicmaterials-Part 2.Unaloyedtitanium (ISO 5832-2.2018,MOD) Released on 2024-10-28 2026-11-01 implementation State Administration for Market Regulation The National Standardization Administration issued ForewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document is Part 2 of GB 4234 "Metallic materials for surgical implants". GB 4234 has been published in the following parts. --- Part 1.Forged stainless steel; --- Part 2.Pure titanium; --- Part 3.Wrought titanium-6 aluminium-4 vanadium alloy; --- Part 4.Cast cobalt-chromium-molybdenum alloys; --- Part 7.Forgeable and cold worked cobalt-chromium-nickel-molybdenum-iron alloys; --- Part 9.Forged high nitrogen stainless steel; --- Part 12.Wrought cobalt-chromium-molybdenum alloys. This document is modified to adopt ISO 5832-2.2018 "Metallic materials for surgical implants - Part 2.Pure titanium". This document has the following structural adjustments compared to ISO 5832-2.2018. --- Note 1 in Table 2 corresponds to paragraph 2 of Chapter 1 of ISO 5832-2.2018; --- Note 2 in Table 2 corresponds to the note in Chapter 1 of ISO 5832-2.2018; --- Footnote d in Table 2 corresponds to footnote e in Table 2 in ISO 5832-2.2018. The technical differences between this document and ISO 5832-2.2018 and their reasons are as follows. --- ISO 6892-1 (see Chapter 7) was replaced by the normative reference GB/T 228.1 to adapt to my country's technical conditions; --- ISO 7438 (see Chapter 7) was replaced by the normative reference GB/T 232 to adapt to my country's technical conditions; --- Added GB/T 4698 (all parts) (see Chapter 7); --- Added GB/T 6394 (see Chapter 7); --- The test method for the parameter "grain size" in Table 3 has been increased from GB/T 6394 (see Chapter 7) to adapt to my country's technical conditions, and increased Operability. The following editorial changes were made to this document. --- Deleted footnote d in Table 2 of ISO 5832-2.2018. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed and coordinated by the State Food and Drug Administration.IntroductionImplants are high-risk medical devices, and their material properties are essential parameters for preclinical evaluation to ensure the safety of implants after implantation in the human body. GB 4234 "Metallic Materials for Surgical Implants" series of standards aims to standardize the performance of metallic materials for surgical implants. The requirements and test methods are intended to consist of the following parts. --- Part 1.Wrought stainless steel. The purpose is to standardize the performance requirements and test methods of wrought stainless steel materials for surgical implants. --- Part 2.Pure titanium. The purpose is to standardize the performance requirements and test methods of pure titanium materials for surgical implants. --- Part 3.Wrought titanium-6 aluminum-4 vanadium alloy. The purpose is to standardize the properties of wrought titanium-6 aluminum-4 vanadium alloy materials for surgical implants. Requirements and test methods. --- Part 4.Cast cobalt-chromium-molybdenum alloy. The purpose is to specify the performance requirements of cast cobalt-chromium-molybdenum alloy materials for surgical implants and test methods. --- Part 5.Wrought cobalt-chromium-tungsten-nickel alloy. The purpose is to standardize the properties of wrought cobalt-chromium-tungsten-nickel alloy materials for surgical implants. Requirements and test methods. --- Part 6.Wrought cobalt-nickel-chromium-molybdenum alloy. The purpose is to standardize the properties of wrought cobalt-nickel-chromium-molybdenum alloy materials for surgical implants. Requirements and test methods. --- Part 7.Forgeable and cold worked cobalt-chromium-nickel-molybdenum-iron alloys. The purpose is to specify forgeable and cold worked cobalt-chromium-nickel-molybdenum-iron alloys for surgical implants. Performance requirements and test methods for cobalt-chromium-nickel-molybdenum-iron alloy materials. --- Part 9.Forged high nitrogen stainless steel. The purpose is to standardize the performance requirements and Test method. --- Part 11.Wrought titanium-6 aluminium-7 niobium alloy. The purpose is to specify the wrought titanium-6 aluminium-7 niobium alloy material for surgical implants. Performance requirements and test methods. --- Part 12.Wrought cobalt-chromium-molybdenum alloys. The purpose is to specify the performance requirements of wrought cobalt-chromium-molybdenum alloy materials for surgical implants. Summation test method. There is no known surgical implant material that has been proven to be completely non-toxic to the human body. However, the materials covered in this document Long-term clinical applications have shown that if applied appropriately, the expected level of biological response is acceptable. Surgical implant metal materials Part 2.Pure titanium1 ScopeThis document specifies the performance requirements for pure titanium for surgical implants and describes the corresponding test methods. This document applies to the testing and evaluation of pure titanium for surgical implants.2 Normative referencesThe contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 228.1 Tensile tests on metallic materials - Part 1.Test methods at room temperature (GB/T 228.1-2021, ISO 6892-1. 2019,MOD) GB/T 232 Metallic materials bending test method (GB/T 232-2024, ISO 7438.2020, MOD) GB/T 4698 (all parts) Chemical analysis methods for titanium sponge, titanium and titanium alloys GB/T 6394 Determination of average grain size of metals size) GrainSize)3 Terms and definitionsThere are no terms or definitions that require definition in this document.4 Chemical compositionThe chemical composition of the alloy shall be in accordance with the method specified in Chapter 7. The chemical composition can be analyzed by ingot analysis, and the hydrogen element should be determined after the final heat treatment and pickling procedures. Table 1 Chemical composition element Chemical composition (mass fraction) 1ELI Level 1 Level 2 Level 3 Level 4A and Level 4B Nitrogen (N) ≤0.012 ≤0.03 ≤0.03 ≤0.05 ≤0.05 Carbon (C) ≤0.03 ≤0.08 ≤0.08 ≤0.08 ≤0.08 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 4234.2-2024_English be delivered?Answer: Upon your order, we will start to translate GB 4234.2-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 4234.2-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB 4234.2-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |