Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB 3096-2008 PDF English

US$85.00 · In stock · Download in 9 seconds
GB 3096-2008: Environmental quality standard for noise
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB 3096: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB 3096-200885 Add to Cart Auto, 9 seconds. Environmental quality standard for noise Valid
GB 3096-1993199 Add to Cart 2 days Standard of environmental noise of urban area Measuring method of environmental noise urban area Obsolete

Similar standards

GB/T 14848   GB 3095   GB 12348   GB/T 15190   

GB 3096-2008: Environmental quality standard for noise

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB3096-2008
Z52 National Standard of the People's Republic of China s.fl~A~~'illilirt~/l Replace GB 3096-93 GB/T 14623-93 Environmental Quality Standard for Noise ISSUE ON. AUGUST 19, 2008 Implemented on: OCTOBER 1, 2008 Issued by Ministry of Environmental Protection of the People's Republic of China General Administration of quality Supervision, Inspection and Quarantine of the People's Republic of China

Table of Contents

Applicable Scope .. l 2 Normative References . 1 3 Terms and Definitions . 1 4 Classification of Acoustical Environment Function Zone .. 3 5 Environmental Noise Limit .. 4 6 Requirements in Environmental Noise Monitoring .. 4 7 Requirements in Division of Acoustical Environment Function Zone . 6 8 Requirements in Standard Implementation .. 6 Appendix A (Informative) Definitions of traffic arteries .. 8 Appendix B (Normative) Monitoring Method of Acoustical Environment Function Zone .. 10 Appendix C (Normative) Monitoring Method of Noise-sensitive Building .. 13 Environmental Quality Standard for Noise 1 Applicable Scope The standard specifies the environmental noise limit and the measuring method of Class 5 acoustical environment function zone. The standard is applicable to the assessment and the management of acoustical environment quality. The standard is not applicable to the regions at airport periphery due to the noise influence of plane passing (taking off, landing and fly-by).

2 Normative References

The following documents or partial provisions of them are referenced in this standard. For undated references, the effective edition of the normative document referred to apply in the standard. GB 3785 Electric, Sonic Properties and Measuring Methods for Sound Level Meters GB/T 15173 Sound Calibrators GB/T 15190 Technical Specification to Determinate the Suitable Areas for Environmental Noise of Urban Area GB/T 17181 Integrating-averaging Sound Level Meters GB/T 50280 Standard for Basic Terminology of Urban Planning JTG BOl Technical Standard of Highway Engineering

3 Terms and Definitions

This following terms and definitions are applicable to this standard. 3.1 A-weighted sound pressure level It is referred to the sound pressure level measured through the A-weighting network, and indicated as LA dB (A). 3.2 Equivalent continuous A-weighted sound pressure level It is referred to the average energy value of A-weighted sound pressure level within the specified measured time, indicated by LAeq,T (Leq), and the unit is dB (A). Except the specialized requirements, the noise limits in this standard are referred to the equivalent continuous A-weighted sound pressure level (hereinafter referred to as "equivalent continuous level"). According to the definition hereof, the equivalent continuous level is calculated according the following formula. The term "city" applies to a municipality directly under the Central Government, a city or a town established as one of the administrative divisions of the country. City proper, suburban area, city administrative region and other areas panned due to urban construction and development are urban planning area. 3.8 Rural Area It is referred to the other area except urban planning area, e.g. village, town. The term "village" is referred to the settlement based by villager for inhabitation and production. The term "town" is referred to the non-organizational town as a regional economy, culture and living service center that is developed from bazaar located at countryside and nationality town people's government in accordance with the approve of country-level people's government. 3.9 Traffic artery It is referred to railway (except railway siding), speedway, arterial highway, secondary road, city expressway, city main truck highway, city second trunk, city rail line (ground segment) and navigable inland channel. And it shall be determined in accordance with railway, communication and city planning. The definitions of above traffic artery types are detailed in Appendix A. 3.10 Noise-sensitive buildings It is referred to the buildings that need be kept quite, e.g. hospital, school, organ, research organization and residence. 3.11 Burst noise It is referred to the noise that features sudden occurrence, short duration and higher strength, E.g. noises generated by boiler gas exhausting, engineering explosion etc ..

4 Classification of Acoustical Environment Function Zone

According to the function feature and environmental quality requirement of the regions, the acoustical environment function zone may be classified as. Class 0 acoustical environment function zone. zones that need be kept quite in particular, like convalescent district. Class I acoustical environment function zone. the zones that are mainly oriented in residence, medical treatment/ hygiene, cultural education, scientific research design and administration office, and need be kept quite. Class II acoustical environment function zone. the zones that are mainly oriented in commercial finance and village fair trade, as well as inhabitation, trade and industry combined, and that need kept quite. Class III acoustical environment function zone. the zones that are oriented in industrial The measuring instruments shall be integrating-averaging sound level meters of Type II or higher level, or environmental noise automatic monitor. The performance of adopted measuring instruments shall meet the provisions in GB 3 785 and GB/T 17181, and the instruments shall be calibrated regularly. The deviation of readings of the instruments calibrated by sound calibrators before and after the measurement shall not be larger than 0.5dB; otherwise, the measurement is ineffective. The sound calibrators shall meet the requirements in GB/T 15173 on Class I or II sound calibrators. Additionally, the microphones shall be equipped with wind shield cover during the measurement. 6.2 Measuring Point Selection According to the monitoring object and the purpose, the three following measuring point conditions (location of microphones) may be adopted to carry out the environmental noise measurement. a) Normal outdoor The measuring points shall be at least 3.5m away from any reflector (except ground), and l .2m over the ground. The measuring points may be emplaced on the high-rise building in case of need, to enlarger the noise receiving scope of the monitoring. If the monitoring car is adopted, the microphone shall be fixed l .2m over the car top. b) Noise-sensitive building outdoor Outside the noise-sensitive building, the measuring pints shall be 1 m away from the wall or the window, and l .2m over the ground. c) Noise-sensitive building indoor The measuring points shall be at least lm away from the wall face and other reflection plane, I.Sm away from the window, and l.2m-1.5m over the ground. 6.3 Meteorological condition The measurement shall be taken out under the condition of no rain/snow, no lightning, and wind speed less than 5m/s. 6.4 Monitoring Type and Method In accordance with the monitoring object and the purpose, the environmental noise monitoring is classified as acoustical environment function zone monitoring and noise- sensitive building monitoring. And the monitoring methods in Appendix B and Appendix C shall be adopted respectively. 6.S Measuring Record The measuring record shall include the following items. a) Date, time, site and measuring crew; b) Instrument model, serial number and calibration record; c) Meteorological conditions of the measurement (weather conditions like wind A.1 Railway

Appendix A

(Informative) Definitions of traffic arteries It is referred to the transport system of both travelers and goods, which runs in fixing steel rail in the traction form of power-centralized or power dispersed system. A.2 Expressway According to JTG BO 1, the definition is as following. Multiple lane highway provided for vehicles running of divided direction or lane, and which the access shall be totally controlled, including. Four-lane expressway shall be capable to run the annual average daily traffic of 25000-55000 (replacement small buses); Six-lane expressway shall be capable to run the annual average daily traffic of 45000-80000 (replacement small buses); Eight-lane expressway shall be capable to run the annual average daily traffic of 60000-100000 (replacement small buses). A.3 First-class Road According to JTG BOl, the definition is as following. Multiple lane highway provided for vehicles running of divided direction or lane, and which the access shall be totally controlled as required, including. Four-lane first-class road shall be capable to run the annual average daily traffic of 15000-30000 (replacement small buses); Six-lane first-class road shall be capable to run the annual average daily traffic of 25000-55000 (replacement small buses). A.4 Secondary Road According to JTG BOl, the definition is as following. It is referred to the double lane highway provided for vehicle running. Double lane first-class road shall be capable to run the annual average daily traffic of 25000-55000 (replacement small buses). A.5 City expressway According to GB/T 50280, the definition is as following. It is referred to the roads that have four or more motor roads and a medial divider in the middle of the urban highway, and are provided for vehicle running at higher velocity, which

Appendix B

(Normative) Monitoring Method of Acoustical Environment Function Zone B.1 Monitoring Purpose The purpose hereof is to assess the day-time and night-time acoustical environment quality of acoustical environment function zoned, and to get clear the spatiotemporal distribution of function zone environmental noises. ... ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB 3096-2008 be delivered?Answer: The full copy PDF of English version of GB 3096-2008 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 3096-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 3096-2008_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 3096-2008 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB 3096-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 3096-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB 3096-2008?

A step-by-step guide to download PDF of GB 3096-2008_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 3096-2008".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9