GB/T 22603-2025 English PDFGB/T 22603: Historical versions
Basic dataStandard ID: GB/T 22603-2025 (GB/T22603-2025)Description (Translated English): Tebuconazole wettable powder Sector / Industry: National Standard (Recommended) Date of Implementation: 2026-03-01 Older Standard (superseded by this standard): GB/T 22603-2008 GB 22603-2008: [GB/T 22603-2008] Tebuconazole wettable powders---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Tebuconazole wettable powders ICS 65.100.30 G25 National Standards of People's Republic of China Tebuconazole WP Posted 2008-12-17 2009-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThe standard Chapter 3, Chapter 5 is mandatory, the rest are recommended. This standard FAO specification 494/WP/S/F (2000) "Tebuconazolewettablepowders" degree of non-conformity Equivalent. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee on Pesticides (SAC/TC133) centralized. This standard is drafted by. Shenyang Chemical Research Institute. Participated in the drafting of this standard. Shandong Huayang Technology Co., Ltd. Jiangsu Feng Deng pesticides, Jiang Su Qizhou green chemical shares Parts Co., Chemical Co., Ltd. Jiangsu dragon. The main drafters of this standard. Jiangmin Yi, Li Xiujie, Bing-Wen, Gengrong Wei, Hu Chunhong, of cloud point. Tebuconazole WP The product is an active ingredient tebuconazole pent other name, structural formula and basic physicochemical parameters are as follows. ISO common name. Tebuconazole CAS Registry Number. 107534-96-3 CIPAC Numeric Code. 494 Chemical Name. (RS) -1- (4- chlorophenyl) -4,4-dimethyl -3- (1H-1,2,4- triazol-1-ylmethyl) pentan-3-ol Structure. Empirical formula. C16H22ClN3O Molecular Weight. 307.8 (according to 2007 international relative atomic mass) Biological activity. bactericidal Melting point. about 102.4 ℃ Vapor pressure (20 ℃). 0.013mPa Solubility (20 ℃). water 32mg/L; dichloromethane greater than 200g/L; hexane of less than 0.1g/L; isopropanol, toluene, 50g/L ~ 100g/L Stability. at pH 4 ~ 9,22 ℃ hydrolysis DT50 is greater than 1 year.1 ScopeThis standard specifies the tebuconazole WP requirements, test methods and marking, labeling, packaging, storage and transportation. This standard applies to processed from Tebuconazole original drug, suitable additives and fillers made of tebuconazole WP.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 1600 Determination of Water Pesticides Determination of GB/T 1601 Pesticides pH value GB/T 1604 Goods pesticide regulations for acceptance GB/T 1605-2001 Sampling Method commercial pesticides GB 3796 pesticide packaging General GB/T 5451 WP Pesticide wettability measurement method GB/T 14825-2006 Method for determination of pesticide suspension GB/T 16150 pesticide powder, wettable powder fineness measurement method GB/T 19136 Determination of Pesticide Thermal storage stability3 Requirements3.1 Composition and appearance. The product shall comply with Tebuconazole original drug with a suitable standard of processing additives and fillers made uniform loose powder, There should be no lumps. 3.2 tebuconazole WP should meet the requirements of Table 1. Table 1 tebuconazole WP Quality Control Project Index project index 80% 25% Tebuconazole mass fraction /% 80.0 + 25.0 + 1.5-1.5 2.5-2.5 Moisture content /% ≤ 3.0 pH range 6.0 to 10.0 Suspension rate /% ≥ 75 Wetting time/s ≤ 90 Fineness (through 45μm test sieve) /% ≥ 98 Thermal storage stability test a qualified When a normal production, heat storage stability test was measured at least once every three months. Test Method 4 4.1 Sampling According to GB/T 1605-2001 "on solid preparation sampling" approach. Determining sample package using a random number table method; the final sample size Not less than 100g. 4.2 Identification Test Liquid chromatography --- The identification test can be carried out simultaneously with the determination of the mass fraction of tebuconazole. Under the same chromatographic operating conditions, the test The retention time of the sample solution and the standard solution to a peak of tebuconazole chromatographic retention time, the relative difference should be 1.5% Fewer. 4.3 Determination of the mass fraction of tebuconazole 4.3.1 High performance liquid chromatography (Arbitration Act) 4.3.1.1 Method summary Sample was dissolved in methanol, methanol + water as the mobile phase, use as filler in Nova-PakC18 stainless steel column and UV detector (220nm), the sample of tebuconazole high performance liquid chromatography and determination. 4.3.1.2 Reagents and solutions Methanol; Water. The new secondary steam distilled water; Tebuconazole Sample. Known tebuconazole mass fraction ≥99.0%. 4.3.1.3 Instruments High performance liquid chromatography. a variable wavelength UV detector; Chromatographic data processor; Column. 150mm × 3.9mm (. I.d) stainless steel column, built-Nova-PakC185μm filler (or equivalent effect Chromatography column); Filter. filter pore size of about 0.45μm; Micro injector. 50μL; Quantitative sample line. 5μL; Ultrasonic cleaner. 4.3.1.4 HPLC operating conditions Mobile phase. ψ (CH3OH.H2O) = 65.35; Flow rate. 1.0mL/min; Column temperature. room temperature (temperature change should not exceed 2 ℃); Detection wavelength. 220nm; Injection volume. 5μL; Retention time. tebuconazole about 7.0min. It said operating parameters are typical, according to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results. Typical tebuconazole WP HPLC is shown in Figure 1. 1 --- tebuconazole. Figure 1 tebuconazole WP High Performance Liquid Chromatographic 4.3.1.5 Measurement procedure 4.3.1.5.1 Preparation of standard solution Weigh 0.1g tebuconazole standard (accurate to 0.0002g), a 50mL volumetric flask, dilute to the mark with methanol, ultrasonic oscillation 5min make sample dissolution, cooled to room temperature and shake well. Using a pipette to take the above solution 5mL to 50mL volumetric flask, diluted with methanol to Mark and shake. 4.3.1.5.2 Preparation of sample solution Weigh 0.1g sample containing tebuconazole of (accurate to 0.0002g), a 50mL volumetric flask, dilute to the mark with methanol, ultrasonic Oscillation 5min make sample dissolution, cooled to room temperature and shake well. Using a pipette to take the above solution 5mL to 50mL volumetric flask with methanol Diluted to the mark, shake, filtration. 4.3.1.5.3 Determination Under these operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles tebuconazole peak area relative change After less than 1.5%, according to the solution, sample solution, sample solution, standard order of standard solution was measured. 4.3.1.5.4 Calculation Tebuconazole sample mass fraction of 1 (%), according to equation (1). 1 = (1) Where. A1 --- the standard solution, the average tebuconazole peak area; The A2 --- sample solution, alcohol tebuconazole average peak area; --- Tebuconazole standard mass fraction, expressed as a percentage. 4.3.1.6 allowable difference The difference between two parallel determination results, 25% should be less than 0.5%, 80% should be less than 1.0%, measured as the arithmetic mean result. 4.3.2 Capillary Gas Chromatography 4.3.2.1 Method summary Sample was dissolved in chloroform, dicyclohexyl phthalate esters as internal standard, using a HP-5 (5% phenyl methyl silicone) coated quartz wool wall Fine column, and a flame ionization detector, the sample of tebuconazole capillary gas chromatography and determination. 4.3.2.2 Reagents and solutions Chloroform; Tebuconazole standard. a known mass fraction ≥99.0%; Dicyclohexyl phthalate ester. not interfere with the analysis of impurities; Internal standard solution. Weigh 2.0g dicyclohexyl phthalate esters in 500mL volumetric flask, dissolved with chloroform, constant volume, Shake well. 4.3.2.3 Instruments Gas chromatograph. with flame ionization detector; Column. 30m × 0.32mm (. I.d) quartz capillary column, wall coated HP-5 (5% phenyl methyl silicone), film thickness 0.25μm; Chromatographic data processor or chromatography workstation. 4.3.2.4 GC operating conditions Temperature (℃). Room 220 column, the gasification chamber 260, detection chamber 280; Gas flow rate (mL/min). carrier gas (N2) 1.8, hydrogen gas 40, air 400, the compensation gas 25; Split ratio. 40.1; Injection volume. 1.0μL; Retention time. tebuconazole about 7.5min, internal standard about 10.4min. GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, In order to obtain the best results. A typical gas chromatogram tebuconazole WP and the internal standard is shown in Figure 2. 1 --- tebuconazole; 2 --- internal standard. Figure 2 tebuconazole wettable powder with a gas chromatograph internal standard 4.3.2.5 Measurement procedure 4.3.2.5.1 preparation of standard solution Weigh tebuconazole standard 0.05g (accurate to 0.0002g), placed in a glass bottle stopper, with a pipette accurate internal standard was added 10mL Solution, shake. 4.3.2.5.2 preparation of the sample solution Weigh the sample containing tebuconazole 0.05g of (accurate to 0.0002g), placed in a glass bottle stopper, with the use and 4.3.2.5.1 With a pipette accurately added internal standard solution 10mL, shake, filtration. 4.3.2.5.3 Determination Under the above chromatographic operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles tebuconazole and internal standard After the change of the relative peak area ratio of less than 1.5%, according to the solution, the sample solution, the sample solution and standard sequence analysis of the standard solution Determination. 4.3.2.5.4 Calculation The two needle sample solution and measured before and after the two doses of the standard sample solution tebuconazole and the internal standard peak area ratio of the average, respectively. Tebuconazole sample mass fraction of 1 '(%) according to equation (2). 1 '= (2) Where. --- Standard samples tebuconazole mass fraction, expressed as a percentage. 4.3.2.6 allowable difference The difference between two parallel determination results, 25% should be less than 0.5%, 80% should be less than 1.0%, measured as the arithmetic mean result. 4.4 Determination of Moisture According to GB/T 1600 in the "azeotropic distillation method". According to GB/T 1601 carried out. 4.6 Determination of the suspension rate 4.6.1 Liquid Chromatography According to GB/T 14825-2006 4.1 performed. Weigh 0.4g sample containing tebuconazole of (accurate to 0.0002g), the bottom of the cylinder 25mL suspension is fully transferred to 100mL volumetric flask with methanol to the mark, in the ultrasonic oscillating 3min, standing, after filtration, 4.3.1 Determination of mass tebuconazole calculate the suspension rate. 4.6.2 Gas Chromatography According to GB/T 14825-2006 4.1 performed. Weigh 0.4g sample containing tebuconazole of (accurate to 0.0002g), the bottom of the cylinder 25mL and the whole suspension was transferred to a 100mL beaker, and the same one used 4.3.2.5.1 pipette accurately the added 10mL Standard solution, then add 10mL of chloroform, in the ultrasonic oscillating 3min, standing, after filtration, measured according to 4.3.2 tebuconazole quality meter Operators suspended rate. 4.7 Determination of wetting time According to GB/T 5451 carried out. 4.8 Determination of fineness According to GB/T 16150 in the "wet sieve method". 4.9 Thermal storage stability test According to GB/T 19136 in "powder formulations" to. After the heat storage tebuconazole content should not be less than the reservoir before the mass fraction of tebuconazole 97% suspension rate should meet the standard requirements. 4.10 Product inspection and acceptance Product inspection and acceptance shall comply with GB/T 1604's. Treatment of extreme values, using the rounding value comparison method. 5 marking, labeling, packaging, storage and transportation 5.1 tebuconazole WP signs, labeling and packaging should comply with the provisions of GB 3796. 5.2 tebuconazole WP application bag lined with clean plastic bag or cardboard drum lined with clean plastic bags, each containing a net weight Generally not more than 15kg. Also available upon request or order agreement, the use of other forms of packaging, it should comply with the provisions of GB 3796. 5.3 tebuconazole WP package should be stored in well-ventilated, dry coffers. 5.4 storage, prevent moisture and sunlight, no food, seed, feed mix, avoid contact with skin, eyes, mouth and nose to prevent inhalation. 5.5 Security. This product is a fungicide. Are swallowed and inhaled toxic, it can penetrate through the skin. Wear protective goggles and rubber gloves when using this product wear Necessary protective clothing. After spraying wash with soap and water. Coverage should be immediately sent to hospital symptomatic treatment. 5.6 Warranty. under the specified storage conditions, tebuconazole guarantee of wettable powders, starting from the date of manufacture 2 years. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 22603-2025_English be delivered?Answer: Upon your order, we will start to translate GB/T 22603-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 22603-2025_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 22603-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 22603-2025?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 22603-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |