GB 19079.4-2014 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 19079.4-2014: Operation conditions and technical requirements for gymnasium and playground -- Part 4: Sport climbing place Status: Valid GB 19079.4: Historical versions
Basic dataStandard ID: GB 19079.4-2014 (GB19079.4-2014)Description (Translated English): Operation conditions and technical requirements for gymnasium and playground -- Part 4: Sport climbing place Sector / Industry: National Standard Classification of Chinese Standard: Y55 Classification of International Standard: 97.220 Word Count Estimation: 7,725 Date of Issue: 9/3/2014 Date of Implementation: 1/1/2015 Older Standard (superseded by this standard): GB 19079.4-2005 Quoted Standard: GB/T 10001.1; GB/T 23268.1 Regulation (derived from): People's Republic of China Announcement of Newly Approved National Standards No. 21 of 2014 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies climbing open spaces should have the basic conditions and basic standards. This Standard is applicable to all types of climbing to the public and open spaces. GB 19079.4-2014: Operation conditions and technical requirements for gymnasium and playground -- Part 4: Sport climbing place---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Operation conditions and technical requirements for gymnasium and playground.Part 4. Sport climbing place ICS 97.220 Y55 National Standards of People's Republic of China Replacing GB 19079.4-2005 Sports venues open conditions and technical requirements Part 4. Rock Climbing place playground-Part 4. Sportclimbingplace Issued on. 2014-09-03 2015-01-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Qualifying 1 5 places, facilities and conditions 1 6 health and environmental management 2 7 Security 2ForewordAll technical content in this Part of GB 19079 is mandatory. GB 19079 "sports venues open conditions and technical requirements" is divided into the following sections. --- Part 1. swimming places; --- Part 2. Karting place; --- Part 3. Bungee place; --- Part 4. rock climbing places; --- Part 5. Skating place; --- Part 6. skiing; --- Part 7. figure skating place; --- Part 8. Shooting place; --- Part 9. Archery place; --- Part 10. Dive sites; --- Part 11. rafting place; --- Part 12. gliding wing place; --- Part 13. Balloon and Airship place; --- Part 19. expansion spaces; --- Part 20. hockey place; --- Part 21. Boxing place; --- Part 22. Taekwondo place; --- Part 23. trampoline place; --- Part 24. Aircraft movement places; --- Part 25. skydiving place; --- Part 26. aerospace model places; --- Part 27. Directional, radio direction finding places; --- Part 28. Sanda place; --- Part 29. climbing places; --- Part 30. Mountain outdoor venues; --- Part 31. Alpine Adventure venues; This is Part 4 GB 19079's. This section based on GB/T 1.1-2009 given rule drafting. This Part replaces GB 19079.4-2005 "sports venues open conditions and technical requirements - Part 4. rock climbing place", and GB 19079.4-2005 compared to the main technical changes are as follows. --- The "rock place" translated "sportclimbingplace", "artificial rock climbing place" translated "artificalwalclimbing place "," natural climbing places "translated" naturalwalclimbingplace "(see Chapter 3, 2005 edition of Chapter 3); --- The "kg force" in terms of "kN" (see 5.1 and 52, 2005 edition of the 5.1, 5.2 and 5.3.); --- Height on the wall of artificial rock climbing sites, rock climbing and laying mat thickness range is made clear by (see 5.1.8 and 5.3); --- Qualifications of practitioners climbing places made new provisions (see Chapter 4). This section is proposed and managed by the State Sports General Administration. This section is drafted. State Sports General Administration mountaineering Management Center, the State Sports General Administration of Sports Science Institute. The main drafters of this section. Ding Xianghua, Zhao Lei, Cao Rongwu, plum, Shih, Wang Xiao, Wang Li whole, Mao Zuoliang. This section was first released in January 2005, this is the first revision. Sports venues open conditions and technical requirements Part 4. Rock Climbing place1 ScopeGB 19079 of the provisions of this part of climbing open spaces should have the basic conditions and basic technical requirements. This section applies to all types of climbing open to the public place.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 10001.1 Public information graphical symbols - Part 1. Common symbols GB/T 23268.1 sports protective equipment requirements - Part 1. Dynamic mountaineering rope3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 Climbing place sportclimbingplace Place to meet people to rock climbing training, competition, fitness and leisure activities. Note 1. Includes artificial climbing rock climbing sites and natural places. Note 2. The place belongs to the climbing rock climbing places. 3.2 Artificial rock climbing place artificialwalclimbingplace With indoor and outdoor artificial rock wall constructed to carry out the rock climbing places. 3.3 Natural rock climbing place naturalwalclimbingplace Carried out by means of natural rock climbing rock climbing safe place. 3.4 Climbing technical guidance personnel sportclimbinginstructor Teach the theory and technical climbing, rock climbing instructors to carry out activities.4 QualifyingClimbing technical guidance personnel should hold the relevant national vocational qualification certificate before taking. 5 places, facilities and conditions 5.1 Artificial rock climbing places 5.1.1 artificial rock wall installation should comply with the relevant building code requirements. 5.1.2 Each climbing line width of not less than 1.8m. 5.1.3 Each top protection system carrying capacity of not less than 8kN. 5.1.4 Each coupon should be protected direct link structure, and the carrying capacity of not less than 8kN. 5.1.5 slab withstand a static load of not less than 4kN. 5.1.6 slab dynamic load resistance should not be less than 6kN. 5.1.7 pivot hole tensile strength of not less than 3kN. Artificial rock for rock climbing activities 5.1.8 Effective vertical height should not exceed 5m. 5.2 Nature Climbing place 5.2.1 Each top protected fixed carrying capacity of not less than 8kN. 5.2.2 Each coupon fixed protective carrying capacity of not less than 8kN. 5.3 Safety Equipment 5.3.1 The climbing rope should be used to protect Dynamic mountaineering ropes. Dynamic mountaineering ropes shall comply with GB/T 23268.1 requirements. 5.3.2 seat belts, helmets, locks, static rope, sling, hanger, expansion nail, quickdraw, risers, down, brake and other equipment should be protected Climbing-specific products, obtain quality certificate of inspection, and periodic inspection. 5.3.3 for rock climbing activities, protection pad surface should be smooth, no cracks, cushions horizontal direction uniform density, thickness not less than 0.4m, Protection pads coverage outside of the wall from the longitudinal projection of the outer edge of not less than 2.5m. 5.4 Auxiliary Equipment 5.4.1 Public instructions should be consistent with the identification GB/T 10001.1 requirements. 5.4.2 shall be clearly and prominently danger zone warning signs and security facilities. 5.4.3 climbing places should communications equipment, and to ensure unimpeded. 5.4.4 indoor climbing places should be set up broadcasting facilities, toilet, equipment storage warehouse. 6 health, environmental management 6.1 spaces should be ventilated indoor climbing facilities. 6.2 environmental illumination opening period of not less than 100lx.7 Security7.1 should establish and improve the safe production responsibility system for posts, rescue and safety management system, equipment and facilities maintenance system, environmental management and health And other systems. 7.2 should develop emergency response plans. 7.3 shall be provided "climbing INSTRUCTIONS" prominently on matters related to safety and special requirements to make real and clear instructions Warning. 7.4 should place less than a climbing technical rock climbing instructor, rock climbing artificial rock climbing site should be publicized technical guidance personnel prominently Directory and photo. 7.5 induction climbing places employees should wear clearly marked. Emergency evacuation routes and export 7.6 indoor rock climbing venues should be identified and kept clear. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 19079.4-2014_English be delivered?Answer: Upon your order, we will start to translate GB 19079.4-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 19079.4-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB 19079.4-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB 19079.4-2014?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19079.4-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |