GA/T 750-2021 English PDFUS$269.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GA/T 750-2021: Stainless steel autopsy table Status: Valid GA/T 750: Historical versions
Basic dataStandard ID: GA/T 750-2021 (GA/T750-2021)Description (Translated English): Stainless steel autopsy table Sector / Industry: Public Security (Police) Industry Standard (Recommended) Classification of Chinese Standard: A92 Word Count Estimation: 11,112 Issuing agency(ies): Ministry of Public Security GA/T 750-2021: Stainless steel autopsy table---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Stainless steel autopsy table ICS 13.310 CCSA92 People's Republic of China Public Safety Industry Standards Replaces GA/T 750-2008 Stainless Steel Autopsy Table Published on 2021-10-14 2022-05-01 Implementation Published by the Ministry of Public Security of the People's Republic of China forewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" drafted. This document replaces GA/T 750-2008 "Stainless Steel Autopsy Table". Compared with GA/T 750-2008, the main technical changes as follows. --- Added normative references (see Chapter 2); --- Changed terms and definitions (see Chapter 3, Chapter 3 of the.2008 edition); --- Changed the basic parameters (see 4.1, 4.1 of the.2008 edition); --- Changed the technical requirements (see 5.1.1, 5.2.3, 5.3.1.1, 5.3.1.2, 5.3.2.1, 5.3.2.3, 5.4.1.1.1, 5.4.1.1.2, 5.4.1.2, 5.4.1.3 and 5.5,.2008 editions 5.1.1, 5.2.3, 5.3.1.1, 5.3.1.2, 5.3.2.1, 5.3.2.3, 5.4.1.1.1, 5.4.1.1.2, 5.4.1.3, 5.4.1.4 and 5.5); --- Deleted some content in the test method (see 6.2.3 and 6.4.2 of the.2008 edition). This document is proposed by the Criminal Technology Product Sub-Technical Committee (SAC/TC179/SC8) of the National Criminal Technology Standardization Technical Committee and return. This document is drafted by. Wuxi Fanying Police Equipment Co., Ltd., Wuxi Fanying Police Equipment New Technology Co., Ltd., Ministry of Public Security Forensic Identification Center, Chinese Forensic Science Association, Jiangsu Provincial Public Security Department, Zhuhai Municipal Public Security Bureau. The main drafters of this document. Wu Xinzi, Tian Xuemei, Zhai Hengli, Xu Lili, Qin Ying, Kong Linggui. The previous versions of this document and its superseded documents are as follows. ---First published in.2008 as GA/T 750-2008, this is the first revision. Stainless Steel Autopsy Table1 ScopeThis document specifies the technical requirements, test methods, inspection rules, signs, instructions for use, packaging, transportation and storage, etc. This document applies to fixed and liftable stainless steel autopsy tables.2 Normative referencesThe contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document. GB/T 191-2008 Graphical signs of packaging, storage and transportation GB/T 5226.1-2019 Mechanical and Electrical Safety Mechanical and Electrical Equipment Part 1.General Specifications GB/T 9969-2008 General Principles of Instruction Manual for Industrial Products GB/T 13384-2008 General technical conditions for packaging of mechanical and electrical products3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 autopsy table autopsytable Operating table for carrying autopsy examinations. 3.2 An autopsy table that can be raised and lowered within a certain height range. 3.3 Dissection table length lengthofautopsytable The maximum straight-line distance between the two ends of the longitudinal direction. 3.4 dissection table width widthofautopsytable The maximum straight-line distance between the two ends of the transverse direction. 3.5 Dissection table height heightofautopsytable The vertical distance from the edge of the dissection table to the ground. 3.6 The maximum distance used to place cadavers when dissecting. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA/T 750-2021_English be delivered?Answer: Upon your order, we will start to translate GA/T 750-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GA/T 750-2021_English with my colleagues?Answer: Yes. The purchased PDF of GA/T 750-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GA/T 750-2021?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GA/T 750-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |