GA/T 1195-2014 English PDFUS$179.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GA/T 1195-2014: Spectral imaging methods by tunable filter in forensic science
Basic dataStandard ID: GA/T 1195-2014 (GA/T1195-2014)Description (Translated English): Spectral imaging methods by tunable filter in forensic science Sector / Industry: Public Security (Police) Industry Standard (Recommended) Classification of Chinese Standard: A92 Classification of International Standard: 13.310 Word Count Estimation: 5,521 Quoted Standard: GA/T 120-1995 Regulation (derived from): Notice on Publication of Public Safety Industry Standard (Year of 2014); Industry Standard Record Announcement No. 4 of 2015 (No. 184) Issuing agency(ies): Ministry of Public Security Summary: This standard specifies equipment, imaging methods, analysis and processing using filter-type spectral imaging. This standard applies to the judicial organs in dealing with criminal, civil cases and deal with incidents such as traces of evidence in the ac GA/T 1195-2014: Spectral imaging methods by tunable filter in forensic science---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Spectral imaging methods by tunable filter in forensic science ICS 13.310 A92 People's Republic of China Public Security Industry Standards Forensic filter type spectroscopic imaging method Issued on. 2014-10-15 2014-10-15 implementation People's Republic of China Ministry of Public Security ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Distribution of this document Institutions do not assume the responsibility to identify these patents. This standard by the National Standardization Technical Committee of Criminal technical inspection camera Technical Committee (SAC/TC179/SC5) and proposed Centralized. This standard was drafted. Hangzhou Public Security Bureau, Ministry of Public Security Evidence Identification Center. Drafters of this standard. Wang Xufeng, Yu Tao, Huang Wei. Forensic filter type spectroscopic imaging method1 ScopeThis standard specifies the use of filter type spectral imaging equipment, components, imaging methods, analysis and processing. This standard applies to the judiciary in handling criminal and civil cases dealing with accidents and incidents and other events mark evidence optical filter Spectral imaging.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GA/T 120-1995 criminal photography, video glossary3 Terms and DefinitionsGA/T 120-1995 defined by the following terms and definitions apply to this document. 3.1 Spectral imaging spectralimaging By the spectral imager, a plurality of narrow band test record is monochromatic object within a spectrum uniformly distributed densely reflected light Brightness distribution or fluorescence intensity distribution, the formation of a monochromatic image formed by a number of spectral image sets specialized methods. 3.2 Spectral image set spectralimagecube It contains the object brightness distribution of monochromatic light in a narrow band wavelength intervals Multiple image location. Imaging Spectral Imaging (3.1) recorded its Each image point is not only the image points corresponding to the luminance value information material, the material also contains spectral information. Each piece of monochrome image recorded object Distribution of information in the appropriate wavelengths of light brightness, the combination of recording with a single-color image information is distributed in all the selected band monochromatic brightness.4 Equipment4.1 photographic equipment 4.1.1 filter type spectral imager Filter type spectral imager by the tunable wavelength filter, CCD digital camera, lighting and computer and special software, which By tunable wavelength filter and CCD digital camera connected to form the core member. 4.1.2 Lens Ordinary photographic optical lens. 4.1.3 Close-up equipment Close-up lap, close-up bellows, close-up lens, macro lens. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA/T 1195-2014_English be delivered?Answer: Upon your order, we will start to translate GA/T 1195-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GA/T 1195-2014_English with my colleagues?Answer: Yes. The purchased PDF of GA/T 1195-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |