GA/T 1191-2014359 Add to Cart 3 days Guidelines for fire fighting of high-rise buildings Obsolete

Similar standards

GB 4066   GA 578   GB 5135.3   GA/T 998   

Basic data

Standard ID: GA/T 1191-2014 (GA/T1191-2014)
Description (Translated English): Guidelines for fire fighting of high-rise buildings
Sector / Industry: Public Security (Police) Industry Standard (Recommended)
Classification of Chinese Standard: C83
Classification of International Standard: 13.220.10
Word Count Estimation: 8,816
Quoted Standard: GB 5907; GB/T 11651; GB/T 18664; GA 621
Regulation (derived from): Notice on Publication of Public Safety Industry Standard (Year of 2014); Industry Standard Record Announcement No. 4 of 2015 (No. 184)
Issuing agency(ies): Ministry of Public Security
Summary: This standard specifies the terms and definitions, general rules, fire-extinguishing operations and operational safety of high-rise building fire-fighting operations. This standard applies to public security fire brigade high-rise building fire fighting o

GA/T 1191-2014: Guidelines for fire fighting of high-rise buildings

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Guidelines for fire fighting of high-rise buildings ICS 13.220.10 C83 People's Republic of China Public Security Industry Standards High-rise building fire fighting action guide Issued on. 2014-09-28 2014-09-28 implementation People's Republic of China Ministry of Public Security

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard was proposed by the Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee fire fighting and rescue Technical Committee (SAC/TC113/SC10) centralized. This standard is mainly drafted by. Chinese People's Armed Police Force Academy. Participated in the drafting of this Standard. Ministry of Public Security Fire Bureau, the Shanghai Public Security Fire Department, Jiangsu Province Public Security Fire Corps. The main drafters of this standard. Wang Changjiang, Xiadeng You, Jiang Lianrui, business fixed by Liu Hao, Xue Jiao Cai Wu determined, Ma Hong, Weihan Dong, Zhu Xiaoli, Zhang Qingli, Wang Heming, Ma Zhifeng Zhang AUO, Zhou Jianzhong, Li Hai. This standard is the first release. High-rise building fire fighting action guide

1 Scope

This standard specifies the terms and definitions of the high-rise building fire fighting operations, general principles, fighting actions and the security. This standard applies to firefighting force to be high-rise building fire fighting action, a full-time fire brigade can be implemented by reference.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 5907 Fire basic terms of the first part GB/T 11651 Personal protective equipment selection specification GB/T 18664 respirator selection, use and maintenance GA 621 firefighters equipped with standard personal protective equipment

3 Terms and Definitions

GB 5907 and defined the following terms and definitions apply to this document. 3.1 High-rise building high-risebuilding Building height greater than 27m residential buildings and building height greater than the non-single factories, warehouses and other civil construction of 24m. 3.2 Fire fighting plan firefightingplan For fire fighting objects may occur, for fire fighting prearranged plan of action. 3.3 Tiered response gradedresponse Fire fighting force deployed combat formation and action by fire and emergency rescue grading regulations. 3.4 Cooperative Engagement coordinatedfirefighting According headquarters of the unified deployment of the parties responsible for the division of the power of war, combat operations complement each other.

4 General

4.1 high-rise building fire fighting operations adhere to the "save first, scientific rescue" the guiding ideology. 4.2 high-rise building fire fighting action should follow "scenario support, tiered response; a solid-based, fixed-mobile integration; within the main attack, attack and defense both" in principle. 4.3 high-rise building fire fighting action should be established as appropriate fire headquarters, unified leadership by the local government, public security fire brigade specific organization And command, other units together, unit technicians and experts to provide technical support. 4.4 high-rise building fire fighting action should work to strengthen the combat service support for climbing, water supply and other operational aspects.
......

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GA/T 1191-2014_English be delivered?

Answer: Upon your order, we will start to translate GA/T 1191-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GA/T 1191-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GA/T 1191-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.