GA 868-2010 English PDF
Basic dataStandard ID: GA 868-2010 (GA868-2010)Description (Translated English): Wye and siamese Sector / Industry: Public Security (Police) Industry Standard Classification of Chinese Standard: C84 Classification of International Standard: 13.220.10 Word Count Estimation: 8,850 Date of Issue: 2010-05-21 Date of Implementation: 2010-07-01 Older Standard (superseded by this standard): GA 11-1991; GA 12-1991 Quoted Standard: GB/T 1048; GB/T 1173; GB/T 3452.1; GB 12514.1 Regulation (derived from): National Engineering Construction Standardization Information Network News (2010.06.28) Issuing agency(ies): Ministry of Public Security Summary: This standard specifies the terms and definitions, performance and structural parameters and model preparation methods, performance requirements, test methods, inspection rules, and marking, packaging, storage and operating instructions for manifolds and water collectors. This standard is applicable to fire water distributor and water collector. GA 868-2010: Wye and siamese---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Wye and siamese ICS 13.220.10 C84 People's Republic of China Public Security Industry Standards Replacing GA 11-1991, GA 12-1991 Watershed and catchment Issued on. 2010-05-21 2010-07-01 implementation People's Republic of China Ministry of Public Security Foreword4.1,4.2,5.1 this standard to 5.6, Chapter 7, 8.1 for the mandatory provisions, the rest are recommended provisions. This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GA 11-1991 "trap performance requirements and test methods" and GA 12-1991 "sump performance requirements and test method". This standard compared with GA 11-1991, GA 12-1991, the main technical changes are as follows. --- Increasing the terms and definitions; (see Chapter 3) --- Increased packaging and storage; (see 8.2 and 8.3) --- Modify the model designation trap and sump; (see Chapter 4, 1991 edition of Chapter 3) --- Merge the changes at a similar technical performance indicators; (see Chapter 5, 1991 edition of Chapter 4) --- Sealing performance and refinement Strength test trap and sump. (See Chapter 6, 1991 edition of Chapter 5) This standard was proposed by the Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee appliances Fire Fire accessories Technical Committee (SAC/TC113/SC5) centralized. This standard was drafted. Shanghai Fire Research Institute of Ministry of Public Security. The main drafters of this standard. Wang Lijing, Xuyao Liang, Wang Yongfu, Wang Zhihui, Yan Yau high. The previous versions of the release GA 11-1991 case. --- GA 11-1991. The previous versions of the release GA 12-1991 case. --- GA 12-1991. Watershed and catchment1 ScopeThis standard specifies the watershed and catchment of terms and definitions, performance and structural parameters and model preparation methods, performance requirements, test side Method, inspection rules and signs, packaging, storage and use instructions. This standard applies to the fire with a water separator and sump.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 1048 conduit elements PN (nominal pressure) of the definition and selection GB/T 1173 aluminum alloy casting GB/T 3452.1 hydraulic and pneumatic rubber O-rings - Part 1. Dimensions, tolerances GB 12514.1 fire interface - Part 1. General technical conditions for fire interface3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 Join the fire service water mains with multi-strand branch of fire appliances. 3.2 Coupled multi-strand fire water supply trunk and branch fire apparatus.4 performance and structural parameters and the model designation4.1 trap performance and structural parameters Trap performance and structural parameters specified in Table 1. Table 1 name Inlet outlet Interface Type Nominal diameter mm Interface Type Nominal diameter mm A nominal pressure MPa Opening force Two trap Third of the water heater Four water heater Fire Interface Fire Interface 1.6 2.5 ≤200 a nominal pressure should be consistent with GB/T 1048 requirements. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA 868-2010_English be delivered?Answer: Upon your order, we will start to translate GA 868-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GA 868-2010_English with my colleagues?Answer: Yes. The purchased PDF of GA 868-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |