GA 821-2009 English PDF
Basic dataStandard ID: GA 821-2009 (GA821-2009)Description (Translated English): Water crane of fire Sector / Industry: Public Security (Police) Industry Standard Classification of Chinese Standard: C84 Classification of International Standard: 13.220.10 Word Count Estimation: 10,168 Date of Issue: 2009-02-27 Date of Implementation: 2009-06-01 Quoted Standard: GB/T 228; GB/T 1176; GB 4452; GB 5135.6; GB/T 7307; GB/T 9439; GB 12514.1; GA 113 Regulation (derived from): National Engineering Standards Information Network March 16, 2009 News; industry standard filing notice 2010 No. 2 (total 122) Issuing agency(ies): Ministry of Public Security Summary: This standard specifies the terms and definitions, classification and specifications, type compilation, requirements, test methods, inspection rules, requirements for the preparation of the instructions for use and marking, packaging, transportation, storage and so on. This standard applies to fire water cranes. GA 821-2009: Water crane of fire---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Water crane of fire ICS 13.220.10 C84 People's Republic of China Public Security Industry Standards Fire water crane Posted 2009-02-27 2009-06-01 implementation People's Republic of China Ministry of Public Security Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Classification and specifications 1 5 2 model designation 6 requires 2 7 Test Method 3 8 Inspection Rule 4 9 manuals - Requirements 5 10 signs, packaging, transportation and storage 5ForewordThe standard Chapter 4, Chapter 5, Chapter 6 content mandatory, the rest are recommended. The standard proposed by the People's Republic of China Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee on Fire II Technical Committee (SAC/TC113/SC2) centralized. This standard is drafted by. Ministry of Public Security in Tianjin Fire Research Institute. Participated in the drafting of this standard. Heilongjiang Province Public Security Fire Department, Harbin Pipes Factory. The main drafters of this standard. Zhao Yongshun, SUN Jia-Bin Chen Xing, Wangshu Yan, Luo Zongjun high Hun Sen, Song Yang, Secretary Chun Kui. This standard is the first release. Fire water crane1 ScopeThis standard specifies the terms and definitions fire water crane, classification and specifications, model designation, requirements, test methods, inspection rules, instructions for use Book written requirements and signs, packaging, transportation, storage and so on. This standard applies to fire water crane.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 228 metal materials at room temperature tensile test method (GB/T 228-2002, eqv ISO 6892.1998) GB/T 1176 Cast Copper Alloys conditions (GB/T 1176-1987, neq ISO 1338. 1977) GB 4452 outdoor fire hydrant General technical conditions GB 5135.6 Automatic sprinkler systems - Part 6. General Valve GB/T 7307 55o non-sealing pipe thread (GB/T 7307-2001, eqv ISO 228-1.1994) GB/T 9439 Gray Iron Castings GB 12514.1 fire interface - Part 1. General technical conditions for fire interface GA 113 hydrant wrench3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 Urban water supply system for fire water facilities, the underground part (master valve, water discharge means over, open and close linkage) and shoot Min (water diversion pipeline and jacket, fire hose interfaces, rotating mechanism, retractable mechanism, etc.) with a swingable, scalable, antifreeze, hoist Fast, etc., are used for rapid fire, Sheung Shui.4 Classification and specifications4.1 Classification 4.1.1 fire water crane press inlet connection can be divided into. a) socket formula (C); b) flange (F). 4.1.2 fire water crane by adjusting the outlet pipe can be divided into. a) straight-through (Z); b) retractable (S). 4.2 Specifications Intake into nominal diameter 100mm, 150mm, 200mm three. Fire interface is divided into 65mm, 80mm two kinds. Nominal divided 1.0MPa, 1.6MPa two kinds. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA 821-2009_English be delivered?Answer: Upon your order, we will start to translate GA 821-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GA 821-2009_English with my colleagues?Answer: Yes. The purchased PDF of GA 821-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |